• Title/Summary/Keyword: Profile Shift

Search Result 148, Processing Time 0.035 seconds

Proposal and Analysis of Characteristics of a Refractive Index Modulated Distributed Feedback Laser Diode (Refractive Index Modulated Distributed Feedback Laser Diode의 제안과 특성해석)

  • 김홍국;이홍석;김부균;김병호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.5
    • /
    • pp.88-98
    • /
    • 1999
  • A refractive index modulated (RIM) DFB laser, in which the refractive index of a center region of the upper cladding layer comprising the grating region is different from that of side regions, is proposed to obtain and effective ${\lambda}$/4 phase shift in the center region. Since the coupling coefficient of a center region in a RIM-DFB laser is larger than that of side regions, a RIM-DFB laser has the effect of a distributed coupling coefficient. Simulation results show that RIM-DFB lasers have better operation characteristics - more uniform photon density profile, less SHB effect, and better single mode operation at high injection currents - compared to those of ${\lambda}$/4 phase-shifted DFB lasers and CPM-DFB lasers. In addition, the effect of the center region on the above threshold characteristics of a RIM-DFB laser is investigated.

  • PDF

Operational Characteristics of Methanol Reformer for the Phosphoric Acid Fuel Cell System (인산형 연료전지용 메탄올 연료개질기의 운전 특성)

  • 정두환;신동열;임희천
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.200-207
    • /
    • 1993
  • A methanol reformer was designed and fabricated using a CuO-ZnO low temperature shift catalyst, and its operation characteristics have been studied for the phosphoric acid fuel cell (PAFC) power generation system. The type of reactor was annular Methanol was consumed both for heating and for reforming fuel. Contents of carbon monoxide produced from the reformer increased as the reaction temperatures increased, but decreased as the mole ratios of water to methanol(H$_2$O/CH$_3$OH) increased. At steady state operating conditional, temperature profile of the catalytic reactor of the reformer was well coincide with the model equation, and it took 50 minutes from start to the rated condition of the reformer. When the system was operated at 4/4 and 1/4 of load, thermal efficiencies of the system were 72.3% and 77%, respectively. When the PAFC system was operated with reformed gas in the range of 62 V-37.6 V and 0-147 A, the trend of I-V curve showed a typical fuel tell characteristic. At steady state condition, the flow rates of reforming and combustion methanol were 88.1 mol/h and 50.1 mol/h, respectively.

  • PDF

Swelling-activated $Cl^-$ Channels in Human Salivary Gland Acinar Cells

  • Chung, Ge-Hoon;Sim, Jae-Hyun;Kim, Soung-Min;Lee, Jong-Ho;Chun, Gae-Sig;Choi, Se-Young;Park, Kyung-Pyo
    • International Journal of Oral Biology
    • /
    • v.34 no.3
    • /
    • pp.151-155
    • /
    • 2009
  • The role of $Cl^-$ channels in regulatory volume decrease (RVD) in human salivary gland acinar cells was examined using a whole-cell patch clamp technique. Human tissues were obtained from healthy volunteers or from patients with oromaxillofacial tumors. During the measurements, $K^+$-free solutions were employed to eliminate contamination of whole-cell conductance by $K^+$ currents. When the cells were exposed to a 70% hypotonic solution, outward-rectifying currents, which were not observed in the resting state, were found to have significantly increased both in human labial and parotid gland acinar cells. The amplitudes of the currents were reduced in a low $Cl^-$ bath solution. Furthermore, the addition of $100{\mu}M$ 5-Nitro-2- (3-phenyl propylamino) benzoic acid (NPPB) or $100{\mu}M$ 4,4'-diisothio cyanatostilbene-2,2'-disulphonic acid (DIDS), known to partially block $Cl^-$ channels, significantly inhibited these currents. Its outward-rectifying current profile, shift in reversal potential in a low $Cl^-$ bath solution and pharmacological properties suggest that this is a $Ca^{2+}$-independent, volume activated $Cl^-$ current. We conclude therefore that volume activated $Cl^-$ channels play a putative role in RVD in human salivary gland acinar cells.

COLOGNE BRAND PREFERENCES OF TEENAGERS IN THE PHILIPPINES: MANAGERIAL IMPLICATIONS

  • Ramirez, Roderick V.;Madamba, Jeanette Angeline B.;Tan, Reynaldo L.
    • Asia-Pacific Journal of Business
    • /
    • v.6 no.2
    • /
    • pp.19-33
    • /
    • 2015
  • Studies focusing on the constantly changing buying behavior and product preferences of a booming teen market are rare and this is particularly true in the Philippines. To address this gap in the literature, this study focused on the supermarket brands of cologne preferred by teens in the Philippines such as Lewis & Pearl (L&P), Johnson's Baby Cologne, Juicy, Bench, Ellips, Fiona, Bambini and Baby Flo which are manufactured by various competing companies. Essentially, this study presented and described the profile and buying behavior of cologne users and non-cologne users and determined whether preferential differences existed between these brands. The respondents consisted of 473 teens all over the Philippines stratified in terms of general location via the three major groups of islands in the Philippines: Luzon, Visayas and Mindanao. Respondents came from selected schools in Quezon City in Metro Manila, Sariaya in Quezon Province, Cebu City, and Digos City to represent the Greater Metro Manila Area, Luzon, Visayas and Mindanao, respectively. Findings showed that almost all of the respondents used cologne at varying degrees. In general, teens use several scents and brands of cologne and continually shift from one scent/brand to another scent/brand. This made it difficult for any company to capture loyal consumers. The most popular brands used by teenagers were Bench (61.7%), Lewis and Pearl (59%), Juicy (42%), Afficionado (32%), Fiona (19.3%), Penshoppe (18%), Bambini (12.6%), Ellips (11.3%) and Zen Zest (7.5%). Fragrance or scent is the top priority of teenagers in choosing a cologne brand, followed by brand name, affordability, bottle design and endorser. The spray bottle type of colognes is preferred even if cologne spray bottles are priced higher than the splash cologne bottle type. Managerial implications of these findings for market players, marketing scholars and prospective investors are presented.

  • PDF

Antihypertensive activity of KR-31081, an orally active nonpeptide AT1 receptor antagonist (안지오텐신 수용체 리간드 KR-31081의 생체 내 활성에 관한 연구)

  • Lee, Sung-Hou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3473-3479
    • /
    • 2009
  • The pharmacological profile of KR-31081, a newly synthesized AT1 receptor antagonist, was evaluated in pithed rats, conscious renal hypertensive rats (RHRs) and conscious furosemide-treated beagle dogs. In pithed rats, KR-31081 (i.v.) induced a non-parallel right shift in the dose-pressor response curve to angiotensin II (ID50: 0.05 mg/kg) with a dose-dependent reduction in the maximum responses; this antagonistic effect was about 40 times more potent than losartan (ID50: 1.74 mg/kg) which showed competitive antagonism. KR-31081 did not alter the responses induced by other agonists such as norepinephrine and vasopressin. In RHRs, orally given KR-31081 produced a dose-dependent and long-lasting (>24 h) antihypertensive effect with a higher potency to losartan (ED20: 0.30 and 3.36 mg/kg, respectively). In furosemide-treated dogs, orally given KR-31081 produced a dose-dependent and long-lasting (>8h) antihypertensive effect with a rapid onset of action (time to Emax: 1-1.5 h) and 20-fold greater potency than losartan (ED20: 0.41 and 8.13 mg/kg, respectively). These results suggest that KR-31081 is a potent, orally active AT1 receptor antagonist useful for the research and diagnostic tools as an added exploratory potential.

Increased Activity of Large Conductance $Ca^{2+}-Activated$ $K^+$ Channels in Negatively-Charged Lipid Membranes

  • Park, Jin-Bong;Ryu, Pan-Dong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.4
    • /
    • pp.529-539
    • /
    • 1998
  • The effects of membrane surface charge originated from lipid head groups on ion channels were tested by analyzing the activity of single large conductance $Ca^{2+}-activated\;K^+$ (maxi K) channel from rat skeletal muscle. The conductances and open-state probability ($P_o$) of single maxi K channels were compared in three types of planar lipid bilayers formed from a neutral phosphatidylethanolamine (PE) or two negatively-charged phospholipids, phosphatidylserine (PS) and phosphatidylinositol (PI). Under symmetrical KCl concentrations $(3{\sim}1,000\;mM)$, single channel conductances of maxi K channels in charged membranes were $1.1{\sim}1.7$ times larger than those in PE membranes, and the differences were more pronounced at the lower ionic strength. The average slope conductances at 100 mM KCl were $251{\pm}9.9$, $360{\pm}8.7$ and $356{\pm}12.4$ $(mean{\pm}SEM)$ pS in PE, PS and PI membranes respectively. The potentials at which $P_o$ was 1/2, appeared to have shifted left by 40 mV along voltage axis in the membranes formed with PS or PI. Such shift was consistently seen at pCa 5, 4.5, 4 and 3.5. Estimation of the effect of surface charge from these data indicated that maxi K channels sensed the surface potentials at a distance of $8{\sim}9\;{\AA}$ from the membrane surface. In addition, similar insulation distance ($7{\sim}9\;{\AA}$) of channel mouth from the bilayer surface charge was predicted by a 3-barrier-2-site model of energy profile for the permeation of $K^+$ ions. In conclusion, despite the differences in structure and fluidity of phospholipids in bilayers, the activities of maxi K channels in two charged membranes composed of PS or PI were strikingly similar and larger than those in bilayers of PE. These results suggest that the enhancement of conductance and $P_o$ of maxi channels is mostly due to negative charges in the phospholipid head groups.

  • PDF

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Acetylcholinesterase(AChE)-Catalyzed Hydrolysis of Long-Chain Thiocholine Esters: Shift to a New Chemical Mechanism

  • Jung, Dai-Il;Shin, Young-Ju;Lee, Eun-Seok;Moon, Tae-sung;Yoon, Chang-No;Lee, Bong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.65-69
    • /
    • 2003
  • The kinetic and chemical mechanisms of AChE-catalyzed hydrolysis of short-chain thiocholine esters are relatively well documented. Up to propanoylthiocholine (PrTCh) the chemical mechanism is general acid-base catalysis by the active site catalytic triad. The chemical mechanism for the enzyme-catalyzed butyrylthiocholine(BuTCh) hydrolysis shifts to a parallel mechanism in which general base catalysis by E199 of direct water attack to the carbonyl carbon of the substrate. [Selwood, T., et al. J. Am. Chem. Soc. 1993, 115, 10477- 10482] The long chain thiocholine esters such as hexanoylthiocholine (HexTCh), heptanoylthiocholine (HepTCh), and octanoylthiocholine (OcTCh) are hydrolyzed by electric eel acetylcholinesterase (AChE). The kinetic parameters are determined to show that these compounds have a lower Michaelis constant than BuTCh and the pH-rate profile showed that the mechanism is similar to that of BuTCh hydrolysis. The solvent isotope effect and proton inventory of AChE-catalyzed hydrolysis of HexTCh showed that one proton transfer is involved in the transition state of the acylation stage. The relationship between the dipole moment and the Michaelis constant of the long chain thiocholine esters showed that the dipole moment is the most important factor for the binding of a substrate to the enzyme active site.

Visual Demonstration of Simulated Moving Bed (Simulated Moving Bed Chromatography의 시각적 설명)

  • Oh, Nan Suk;Lee, Chong-Ho;Kim, Jin Il;Koo, Yoon-Mo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.360-365
    • /
    • 2005
  • SMB (simulated moving bed) is a continuous chromatographic process by shifting periodically port position. Binary of mixture, Blue dextran and Orange G, was separated by SMB. These components have unique color individually, that is, Blue dextran is blue and Orange G is orange. It is easy to understand SMB process by observing the shift of color changes in SMB. These components was not adsorbed to stationary phase and isolated by difference of size exclusion factor. Mass transfer coefficient was determined by single pulse test under several flow rate conditions. Operation condition was obtained by standing wave theory and optimized for high purities in extract and raffinate streams. Experiment was performed in open loop 4 zone (2-2-2-2) SMB. There are several advantages in open loop SMB, where extract is product for high purity. It is also easy to control flow rate and monitor experimental state during operation. Experimental, extract and raffinate history is well fitted with simulation results, however, column concentration profile is a little different from simulation results. Purities were 99.5% for extract and 98.9% for raffinate and extract and raffinate yields were obtained as 98.9% and 99.4% respectively.

TREATMENT OF MALOCCLUSION, AS RELATED TO FINGER SUCKING : CASE REPORT (손가락 빨기로 인한 부정교합의 치험례)

  • Moon, Sang-Jin;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • The habit of finger sucking is a reflex occurring in the oral stage, due to nutritive and psychological desire. The habit of finger sucking is considered to be normal till 3 years of age. Dento-skeletal effect on maxillo-mandibular complex including occlusion is naturally correction, when habit stopped before 3 years. If finger sucking continues till $3{\sim}4$ years, Finger sucking leads to severe malocclusion and remarkable discrepancy maxillo-mandibular complex, which is difficult in expectation of natural correction. It is necessary to positive treatment. Treatment of malocclusion, as related to finger sucking is classified two methods. (psychological approach and orthodontic appliance) To stop a habit and to correct severe skeletal discrepancy and malocclusion, $fr\ddot{a}nkel$ appliance is very effective device. This study is to report two cases of treatment of malocclusion, as related to finger sucking. 2 years 10 months old girl with severe overjet, maxillo-mandibular skeletal discrepancy and severe convex facial profile was treated with a FR-II appliance. Finger sucking habit stopped immediately After 16 months, severe overjet, maxillo-mandibular skeletal discrepancy and severe convex facial profile was corrected. 4 years 2 months old girl with midline deviation, mandibular right shift, collateral posterior crossbite and facial asymmetry was treated with a FR-III appliance. Finger sucking habit stopped immediately. After 10 month, Midline deviation, mandibular right shift, collateral posterior crossbite and facial asymmetry were corrected. FR-appliance is a recommendable appliance for a habit breaker and correction of skeletal discrepancy.

  • PDF