• 제목/요약/키워드: Process heat

검색결과 5,877건 처리시간 0.031초

ANODE HEATING AND MELTING IN THE ARGON GTA

  • Terasaki, Hidenori;Tanaka, Manabu;Fujii, Hidetoshi;Ushio, Masao
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.746-751
    • /
    • 2002
  • In order to make clear the physical relation among the arc plasma, the anode heat transfer and the weld penetration, the results of experimental measurements of temperatures of arc plasma, the distributions of heat input and current on the anode and the weld penetration were presented The experimental results showed that the electron temperature above the anode and current and heat input density on the anode was dominated by the position of the cathode. Furthermore, it was showed that electron temperature of arc plasma was dominated by the cathode shape. These results were related with the results of the welded penetration measurements. As a result, it was showed that the electron temperature above the anode and current density distribution on the anode decided the heat input density distribution on the anode and that the heat input density on the anode remarkably dominated the size of the weld penetration in argon GTA welding process. Furthermore, it was suggested that the cathode played the important role in the determination of the weld penetration in argon GTA welding process.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

수증기의 잠열을 이용한 메탄올 수증기 개질기의 특성 연구 (Study on the Characteristics of Methanol Steam Reformer Using Latent Heat of Steam)

  • 천욱래;안강섭;신현길
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.19-24
    • /
    • 2018
  • Fuel cells are used to generate electricity with a reformer. In particular, methanol has various advantages among the fuels for reformer. Methanol steam reformer devices can efficiently supply hydrogen to PEM fuel cell. This study investigated the optimal operation conditions of a methanol steam reforming process. For this purpose, aspen HYSYS was used for the optimization of reforming process. The optimal operating condition could be designed by setting independent variables such as temperature, pressure and steam to carbon ratio (SCR). The optimal temperature and steam to carbon ratio were $250-270^{\circ}C$ and 1.3-1.5, respectively. It is advantageous to operate at a pressure of 15-20 barg, considering the performance of the hydrogen purifier. In addition, a heat exchange network was designed to supply heat constantly to reformer through the latent heat of steam.

적외선 열화상을 활용한 리튬 이온 ESS의 방열설계 성능평가에 관한 연구 (A Performance Evaluation of a Heat Dissipation Design for a Lithium-Ion Energy Storage System Using Infrared Thermal Imaging)

  • 김은지;이경일;김재열
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.105-110
    • /
    • 2020
  • The global battery market is rapidly growing due to the development of vehicles(EV) and wireless electronic products. In particular logistics robots, which hielp to produce EVs, have attracted much interest in research in Korea Because logistics sites and factories operate continuously for 24 hours, the technology that can dramatically increase the operation time of the logistics equipment is rapidly developing, and various high-level technologies are required for the batteries used in. for example, logistics robots. These required technologies include those that enable rapid battery charging as well wireless charging to charge batteries while moving. The development of these technologies, however, result in increasing explosions and topical accidents involving rapid charging batteries These accidents due to the thermal shock caused by the heat generated during the charging of the battery cell. In this study, a performance evaluation of a heat dissipation design using infrared thermal imaging was performed on an energy storage systrm(Ess) applied with an internal heat conduction cooling method using a heating plate.

Solenoid 전동기의 냉각을 위한 수치해석적 연구 (Numerical Analysis of Heat Transfer Characteristics inside a Solenoid Motor System)

  • 정민채;윤상길;윤동진;서정세
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.99-104
    • /
    • 2020
  • In this study, the temperature distribution and heat transfer characteristics of each component in a solenoid motor system were numerically investigated when heat is generated by the steel pad attached to the solenoid ring of the motor. It was found that the internal airflow was complicated by the inflow velocity of air and the rotation of guide rollers and solenoid rings. Based on the numerical results, the tendency for temperature changes in the steel panel was lower due to the contact of the cooling air in the front in the rotational direction, and the peak temperature was at the front of the center. In particular, it was confirmed that as the air inflow rate was increased, the temperature was reduced due to strong convection. The temperature of the iron plate pad was decreased as the convective heat transfer coefficient was linearly increased with increasing airflow around the solenoid ring. In addition, the temperature of the iron plate panel was rapidly increased with increasing heat generation.

실리콘 함유 DLC 박막의 내열특성 (Thermal Stability of Silicon-containing Diamond-like Carbon Film)

  • 김상권;김성완
    • 열처리공학회지
    • /
    • 제23권2호
    • /
    • pp.83-89
    • /
    • 2010
  • Diamond-like carbon (DLC) coating was studied to be a good tribological problem-solver due to its low friction characteristics and high hardness. However, generally hydrogenated DLC film has shown a weak thermal stability above $300^{\circ}C$. However, the silicon doping DLC process by DC pulse plasma enhanced chemical vapor deposition (PECVD) for the new DLC coating which has a good characterization with thermal stability at high temperature itself has been observed. And we were discussed a process for optimizing silicon content to promote a good thermal stability using various tetramethylsilane (TMS) and methane gas at high-temperature. The chemical compositions of silicon-containing DLC film was analyzed using X-ray photoelectron spectroscopy (XPS) before and after heat treatment. Raman spectrum analysis showed the changed structure on the surface after the high-temperature exposure testing. In particular, the hardness of silicon-containing DLC film showed different values before and after the annealing treatment.

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

알루미늄 중력주조용 내구성 도형제의 도형조건에 따른 내마모 및 내열특성 연구 (A Study on the Wear and Heat Resistance Properties of Durable Moldwash Conditions for Al Gravity Die Casting According to Mold Washing Process Condition)

  • 김억수;남궁정;박진하;이광학
    • 한국주조공학회지
    • /
    • 제28권5호
    • /
    • pp.237-241
    • /
    • 2008
  • This study has been carried out to investigate the wear and heat resistant properties of durable moldwash agent for Al gravity casting according to mold washing process conditions. The wear properties of coated specimen were performed by sliding wear testing machine and heat resistance were evaluated by measuring the loss of coated moldwash agent during emerging of coated specimen in Al melts. During testing, experimental variables were mold surface temperature, moldwash agent/distilled wear, and additive concentrations. The lower additive concentration and mold temperature caused the smooth surface roughness of coated specimen, It was found that the specimen coated with moldwash/water ratio 1:3, additive concentration 9wt% and mold temperature higher than $200^{\circ}C$ showed superior wear and heat treatment. Also, these results were supported by fluidity test.

반용융 단조에서 가압유지 시간에 의한 미세조직의 특성 (Microstructural Characteristics by Compression Holding Time in Semi-Solid Forging)

  • 최재찬;박형진;이병목
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 고액공존금속의 성형기술 심포지엄
    • /
    • pp.174-182
    • /
    • 1997
  • The technology of Semi-Solid Forging (SSF) has been actively developed to fabricate near-net-shape products using light and hardly formable materials. Generally, the SSF process is composed of slug heating, forming, compression -holding and ejecting step. After forming step in SSF, the slug is compressed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. The compression holding time that can affect microstructural characteristics and shape of products is important to make decision, where it is necessary to find overall heat transfer coefficient properly which has large effect on heat transfer between slug and die. This paper presents the procedure to predict compression holding time of obtaining the final shaped part with information of temperature and solid fraction for a cylindrical slug at compression holding step in closed-die compression process using heat transfer analysis considering latent heat by means of finite element method. The influence of the predicted compression holding time on microstructural characteristics of products is finally investigated by experiment.

  • PDF

밀폐용기내의 물의 저압 증발 최적조건에 관한 실험적 연구 (An Experimental Study on the Water Evaporation Conditions of the Enclosed Tank)

  • 김세현;신유식;이윤환;정한식;정효민
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 2004
  • Cooling towers are widely used not only for cooling products and equipment in manufacturing process but HVAC(Heating, Ventilation and Air Conditioning) system. As a cooling tower is the terminal apparatus which discharges heat from industrial process, the efficiency of heat exchange in the cooling tower greatly affects to the overall performance of a thermal system. In this paper, we constituted a new water cooling system by using a Latent heat of evaporation in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driven ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows into the ejector. Based on the vacuum pressure by water driven ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF