• Title/Summary/Keyword: Procedure Quality

Search Result 1,858, Processing Time 0.032 seconds

Effects of Cotton Balls of Alcohol and Povidone for Disinfectoin of Skin in Newborns (신생아에서 알코올 솜 및 포비돈 솜의 피부 소독효과 비교)

  • Park, Kyu Chang;Kim, Chang Ryul;Kim, Eun A;Oh, Jae Won;Yum, Myung Kul;Oh, Sung Hee;Moon, Soo Jee;Kang, Jung Oak
    • Pediatric Infection and Vaccine
    • /
    • v.6 no.1
    • /
    • pp.116-122
    • /
    • 1999
  • Purpose : Despite of development of neonatal intensive care, infections, especially catheter-related infection, have been a major problem in newborns on intensive care. Catheter-related infection is closely related to skin colonization so that skin disinfection is crucial to protect newborns from the infection. Cotton balls of seventy percent alcohol made by hospital frequently open to air so that composition of alcohol may be easily evaporated. We hypothesized that 10% povidone would have better disinfection compared to 70% alcohol and normal saline. Methods : The effect of skin disinfection was evaluated in newborn infants who were admitted to the neonatal intensive care unit(NICU) of Hanyang University Kuri Hospital by a skin swab culture before and after disinfectant exposure. Before skin disinfective preparation, the peripheral intravenous catheter insertion sites were swabbed for culture with sterile cotton moistened with normal saline. Cotton balls of 70% alcohol(Alcohol group, n=20) or 10% povidone and 70% alcohol(povidone group, n=20) were randomly selected. Normal saline swabs were used for controls(n=10). After swabbing, the skin swab culture was done on same sites with same procedure. Results : Before skin disinfection, culture-positivity was shown in 9 of 20 leases of alcohol and povidone groups, respectively and in 8 of 10 cases of the controls. After skin disinfection, culture-positivity was still shown in 3 of 9 cases of the Alcohol group, in 2 of 9 of the Povidone group, and in 6 of 8 cases of the controls. Disinfective effect was significantly different among the 3 groups(p=0.0387). The povidone group had significantly better disinfection than the controls(p=0.0156), but the alcohol group was not significantly different from the controls. Conclusion : The cotton balls of povidone had similar effect of disinfection compared to those of alcohol, but better disinfection than the controls. A disinfective effect of the cotton balls of alcohol was not, however, significantly different from the controls. We suggest that purity of alcohol, quality control of cotton balls of alcohol, and disinfection method should be reevaluated.

  • PDF

A Framework for Creating Inter-Industry Service Models in the Convergence Era (융합 서비스 모델 개발 방법론 및 체계 연구)

  • Kwon, Hyeog-In;Ryu, Gui-Jin;Joo, Hi-Yeob;Kim, Man-Jin
    • Asia pacific journal of information systems
    • /
    • v.21 no.1
    • /
    • pp.81-101
    • /
    • 2011
  • In today's rapidly changing and increasingly competitive business environment, new product development in tune with market trends in a timely manner has been a matter of the utmost concern for all enterprises. Indeed, developing a sustainable new business has been a top priority for not only business enterprises, but also for the government policy makers accountable for the health of Its national economy as well as for decision makers in what type of organizations. Further, for a soft landing of new businesses, building a government-initiated industry base has been claimed to be necessary as a way to effectively boost corporate activities. However, the existing methodology in new service and new product development is not suitable for nurturing industry, because it is mainly focused on the research and development of corporate business activities instead of new product development. The approach for developing new business is based on 'innovation' and 'convergence.' Yet, the convergence among technologies, supplies, businesses and industries is believed to be more effective than innovation alone as a way to gain momentum. Therefore, it has become more important than ever to study a new methodology based on convergence in industrial quality new product development (NPD) and new service development (NDS). In this research, therefore, we reviewed any restrictions in the existing new product and new service development methodology and the existing business model development methodology. In doing so, we conducted industry standard collaboration analysis on a new service model development methodology in the private sector and the public sector. This approach is fundamentally different from the existing one in that ours focuses on new business development under private management. The suggested framework can be categorized into industry level and service level. First, in the industry level, we define new business opportunities In occurrence of convergence between businesses. For this, we analyze the existing industry at the industry level to identify the opportunities in a market and its business attractiveness, based on which the convergence industry is formulated. Also, through the analysis of environment and market opportunity at the industry level. we can trace how different industries are lined to one another so as to extend the result of the study to develop better insights into industry expansion and new industry emergence. After then, in the service level, we elicit the service for the defined new business, which is composed of private service and supporting service for nurturing industry. Private service includes 3steps: plan-design-do; supporting service for nurturing industry has 4 steps: selection-make environment- business preparation-do and see. The existing methodology focuses on mainly securing business competitiveness, building a business model for success, and offering new services based on the core competence of companies. This suggested methodology, on other hand, suggests the necessity of service development, when new business opportunities arise, in relation to the opportunity analysis of supporting service based on the clear understanding of new business supporting infrastructure optimization. Meanwhile, we have performed case studies on the printing and publishing field with the restrict procedure and development system to assure the feasibility and practical application. Even though the printing and publishing industry is considered a typical knowledge convergence industry, it is also known as a low-demand and low-value industry in Korea. For this reason, we apply the new methodology and suggest the direction and the possibility of how the printing and publishing industry can be transformed as a core dynamic force for new growth. Then, we suggest the base composition service for industry promotion(public) and business opportunities for private's profitability(private).

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

A Study on the Component-based GIS Development Methodology using UML (UML을 활용한 컴포넌트 기반의 GIS 개발방법론에 관한 연구)

  • Park, Tae-Og;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.2 s.6
    • /
    • pp.21-43
    • /
    • 2001
  • The environment to development information system including a GIS has been drastically changed in recent years in the perspectives of the complexity and diversity of the software, and the distributed processing and network computing, etc. This leads the paradigm of the software development to the CBD(Component Based Development) based object-oriented technology. As an effort to support these movements, OGC has released the abstract and implementation standards to enable approaching to the service for heterogeneous geographic information processing. It is also common trend in domestic field to develop the GIS application based on the component technology for municipal governments. Therefore, it is imperative to adopt the component technology considering current movements, yet related research works have not been made. This research is to propose a component-based GIS development methodology-ATOM(Advanced Technology Of Methodology)-and to verify its adoptability through the case study. ATOM can be used as a methodology to develop component itself and enterprise GIS supporting the whole procedure for the software development life cycle based on conventional reusable component. ATOM defines stepwise development process comprising activities and work units of each process. Also, it provides input and output, standardized items and specs for the documentation, detailed instructions for the easy understanding of the development methodology. The major characteristics of ATOM would be the component-based development methodology considering numerous features of the GIS domain to generate a component with a simple function, the smallest size, and the maximum reusability. The case study to validate the adoptability of the ATOM showed that it proves to be a efficient tool for generating a component providing relatively systematic and detailed guidelines for the component development. Therefore, ATOM would lead to the promotion of the quality and the productivity for developing application GIS software and eventually contribute to the automatic production of the GIS software, the our final goal.

  • PDF

Evaluation on Microbiological Contamination Level of Raw Beef from Retail Markets in Seoul, Korea (서울지역 식육판매점의 우육에 대한 미생물학적 오염도 평가)

  • Ko, Eun-Kyung;Heo, Eun Jeong;Kim, Young Jo;Park, Hyun Jung;Wi, Seong-Hwan;Moon, Jin San
    • Food Science of Animal Resources
    • /
    • v.33 no.3
    • /
    • pp.403-410
    • /
    • 2013
  • This study was performed to evaluate the microbiological contamination level of raw beef from retail markets in Seoul, Korea. The sampling and laboratory test were performed according to the procedure of "Standard for processing and ingredients specification of livestock product" and "Korean food code". Enterotoxin of Staphylococcus aureus isolates were detected using VIDAS$^{(R)}$ and PCR-based methods. Listeria monocytogenes serotyping and genotyping were carried out using Listeria antisera and L. monocytogenes Fingerprinting kit, respectively. A total of 48 samples were collected from 16 retail markets (butcher's shop: 5, department store: 6, supermarket: 5) in 2011. The level of total bacteria counts in the butcher's shop, department store and supermarket were $4.4{\times}10^3$ CFU/g, $3.9{\times}10^5$ CFU/g and $1.0{\times}10^4$ CFU/g, respectively. The concentrations of Escherichia coli of these three retail markets were $6.4{\times}10$ CFU/g, 7.6 CFU/g and $2.0{\times}10$ CFU/g, respectively. Salmonella species was not detected on all samples. However, S. aureus was isolated in the 3 samples (6.25%) from each type of three retail markets. L. monocytogenes was isolated in the 4 samples (8.3%) from department stores. The level of contamination of these foodborne bacteria was less than 100 CFU/g. The enterotoxin-encoding genes of S. aureus isolates were sea, seh, sei and sep gene. The gene similarity of L. monocytogenes isolated from two retail markets by Rep-PCR showed 57.8-98.1% and 68.1-98.1%, respectively. These results suggest that the HACCP guideline for environmental control in slaughterhouse and retail markets should be provided to prevent cross contamination and manage foodborne pathogens such as L. monocytogenes and S. aureus.

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

A Study on Network Hospital and the Ban on Opening and Operating the Muliple Medical Institution (네트워크병원과 의료기관 복수 개설·운영 금지 제도에 관한 고찰)

  • KIM, JOON RAE
    • The Korean Society of Law and Medicine
    • /
    • v.17 no.2
    • /
    • pp.281-313
    • /
    • 2016
  • Our Constitution obliges the state to protect the health of the people, and the Medical Law, which embodied Constitution, sets out in detail the matters related to open the medical institution and one of them is to prohibit the operation of multiple medical institutions In the past, there was a provision stipulating the same purpose. But because the Supreme Court interpreted that several medical institutions could be opened if the medical treatment was not made at the additional medical instition which was opened in the another doctor,s license, multiple medical institutions could be opened and operated. However, some health care providers opened the several medical institutions to another doctor's license just by the excuse of the business management and then did illegal medical cares like the unfair luring of patients, overtreatment, and commition treatment for more profits. So, the health rights of the people came to be infringed on. Accordingly, lawmakers amended the Medical Law for medical personnel not to open and to operate more than one medical institution. As the amended medical law prohibited a medical personnel to open multiple medical institution, some medical personnels insisted that the amended medical law is unconstitutional under which they could not be able to open and operate medical institutions on based on free investment and bring out the benefits of network hospitals. But the regulation to prohibit multiple institutions does not apply only to a medical personnel. Many other experts like lawyer and pharmacist can open only one office under such a restriction. If the regulation goes out of force, the procedure that multiple medical institutions should be opened and operated in the capacity as a medical corporation or a non-profit corporation does not have to be followed. And we should keep in mind that the permission for medical personels to open multiple medical institutions could lead virtually to commercial hospital. If in the nation with a very low rate of public medical service, If only a few medical personnels with capital own many medical institutions and operate commercially them, this could cause a falling-off in quality of medical service, ultimately infringe on the health rights and the life right of the people.

  • PDF

Environmental effects from Natural Waters Contaminated with Acid Mine Drainage in the Abandoned Backun Mine Area (백운 폐광산의 방치된 폐석으로 인한 주변 수계의 환경적 영향)

  • 전서령;정재일;김대현
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.325-337
    • /
    • 2002
  • We examined the contamination of stream water and stream sediments by heavy metal elements with respect to distance from the abandoned Backun Au-Ag-Cu mine. High contents of heavy metals (Pb, Zn, Cu, Cd, Mn, and Fe) and aluminum in the waters connected with mining and associated deposits (dumps, tailings) reduce water quality. In the mining area, Ca and SO$_4$ are predominant cation and anion. The mining water is Ca-SO$_4$ type and is enriched in heavy metals resulted from the weathering of sulfide minerals. This mine drainage water is weakly acid or neutral (pH; 6.5-7.1) because of neutralizing effect by other alkali and alkaline earth elements. The effluent from the mine adit is also weakly acid or neutral, and contains elevated concentrations of most elements due to reactions with ore and gangue minerals in the deposit. The concentration of ions in the Backun mining water is high in the mine adit drainage water and steeply decreased award to down stream. Buffering process can be reasonably considered as a partial natural control of pollution, since the ion concentration becomes lower and the pH value becomes neutralized. In order to evaluate mobility and bioavailability of metals, sequential extraction was used for stream sediments into five operationally defined groups: exchangeable, bound to carbonates, bound to FeMn oxide, bound to organic matter, and residual. The residual fraction was the most abundant pool for Cu(2l-92%), Zn(28-89%) and Pb(23-94%). Almost sediments are low concentrated with Cd(2.7-52.8 mg/kg) than any other elements. But Cd dominate with non stable fraction (68-97%). Upper stream sediments are contaminated with Pb, and down area sediments are enriched with Zn. It is indicate high mobility of Zn and Cd.