• Title/Summary/Keyword: Problem Statement

Search Result 515, Processing Time 0.024 seconds

MACRO-SHEAR BOND STRENGTH AND MICRO-SHEAR BOND STRENGTH OF CEROMER BONDED TO METAL ALLOY AND FIBER REINFORCED COMPOSITE

  • Park Hyung-Yoon;Cho Lee-Ra;Cho Kyung-Mo;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.654-663
    • /
    • 2004
  • Statement of problem. According to the fracture pattern in several reports, fractures most frequently occur in the interface between the ceromer and the substructure. Purpose. The aim of this in vitro study was to compare the macro shear bond strength and microshear bond strength of a ceromer bonded to a fiber reinforced composite (FRC) as well as metal alloys. Material and methods. Ten of the following substructures, type II gold alloy, Co-Cr alloy, Ni-Cr alloy, and FRC (Vectris) substructures with a 12 mm in diameter, were imbedded in acrylic resin and ground with 400, and 1, 000-grit sandpaper. The metal primer and wetting agent were applied to the sandblasted bonding area of the metal specimens and the FRC specimens, respectively. The ceromer was placed onto a 6 mm diameter and 3 mm height mold in the macro-shear test and 1 mm diameter and 2 mm height mold in the micro-shear test, and then polymerized. The macro- and micro-shear bond strength were measured using a universal testing machine and a micro-shear tester, respectively. The macro- and micro-shear strength were analyzed with ANOVA and a post-hoc Scheffe adjustment ($\alpha$ = .05). The fracture surfaces of the crowns were then examined by scanning electron microscopy to determine the mode of failure. Chi-square test was used to identify the differences in the failure mode. Results. The macro-shear strength and the micro-shear strength differed significantly with the types of substructure (P<.001). Although the ceromer/FRC group showed the highest macroand micro-shear strength, the micro-shear strength was not significantly different from that of the base metal alloy groups. The base metal alloy substructure groups showed the lowest mean macro-shear strength. However, the gold alloy substructure group exhibited the least micro-shear strength. The micro-shear strength was higher than the macro-shear strength excluding the gold alloy substructure group. Adhesive failure was most frequent type of fracture in the ceromer specimens bonded to the gold alloys. Cohesive failure at the ceromer layer was more common in the base metals and FRC substructures. Conclusion. The Vectris substructure had higher shear strength than the other substructures. Although the shear strength of the ceromer bonded to the base metals was lower than that of the gold alloy, the micro-shear strength of the base metals were superior to that of the gold alloy.

THE FIT OF ZIRCONIA FORE FABRICATED WITH CAD/CAM SYSTEM (CAD/CAM system으로 제작한 zirconia core의 적합도)

  • Seong Ji-Yun;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.489-500
    • /
    • 2004
  • Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpose : This study was to evaluate the fit related to internal relief and marginal reproducibility of zirconia core fabricated with CAD/CAM system. Materials and methods: The evaluation was based on 30 zirconia cores and 5 IPS-Empress2 cores. Zirconia cores were fabricated in different conditions of internal relief(0, 10, 20, 30, 40 and $50{\mu}m$), and IPS-Empress2 cores were fabricated in accordance with the manufacturer's instructions. Before cementation, the marginal discrepancies or cores were measured on metal die. And then, each core was cemented to stone die, embedded in an acrylic resin and sectioned in two planes(mesiodistally and labiopalatally). The internal gaps were measured at the margin and axial surface. Measurements for the marginal discrepancies, the internal marginal gaps and the internal axial gaps were performed under a measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of ${\times}100$. In addition, the marginal conagurations of metal die, zirconia core and IPS-Empress2 core were examined with SEM(S-2700, Hitachi, Japan). Results : Within the limits of this study the results were as follows. 1. Compared with IPS-Empress2 cores, the marginal discrepancies of zirconia cores had no significant differences. the internal marginal gaps were statistically smaller and the internal axial gaps were statistically larger in each condition of internal relief. 2. The marginal discrepancies and the internal marginal gaps of zirconia cores had no significant differences related to the conditions of internal relief(P>0.05). 3. The internal axial gaps of zirconia cores with $0{\sim}20{\mu}$m for internal relief were significantly larger than that with $50{\mu}m$ (P<(0.0001). 4. SEM micrographs showed favorable marginal reproducibility of zirconia core and smooth texture on the milling surface. Conclusion: The marginal discrepancy and the internal gaps of zirconia core were clinically acceptable and the milling surface was showed smooth texture. For fabrication of the durable esthetic restoration, further investigations on complex design of core, milling accuracy, compatability of enamel porcelain and porcelain firing seems to be needed.

A Study of Perception on Improvement of Environmental Impact Assessment using Strategic Environmental Assessment (전략환경평가를 통한 환경영향평가제도 개선에 대한 인식도 조사 연구)

  • Kim, Im Soon;Kim, Yoon Shin;Moon, Jeong Suk;Han, Sang Wook;Son, Bu Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.3
    • /
    • pp.125-135
    • /
    • 2004
  • Environmental Impact Assessment(EIA) in Korea has been used to improve environmental conservation and decision-making. Since environmental impact statement(EIS) was introduced in 1981 with the promulgation of the Environmental Preservation Act in 1977, which replaced the Pollution Control Act legislated in 1963. With a rapid growth of environmental perception as well as the diversification of development activities, however, it has recently bring about a strong demand for a new assessment process related to the strategic level of policies, plan, programs. Method of this study includes analyses of the situation of local EIA and its problematic issues through survey and analysis of information and data, analysis of the level of environmental awareness of professionals and case studies including analysis of foreign strategic environmental assessment. Accordingly, I have elicited a concept of SEA. In addition, I have studied on costs of environmental assessment, and efficiency of internalization of HIA. The survey was carried between September and November 2003, and 177 professionals were asks to complete a questionnaire. As a result of questionnaire survey of environmental pundits, it revealed that 83.8% of participants were in favor of introduction of strategic assessment. This result demonstrated more or less higher approval rate than those of awareness survey done by the Ministry of Environment, i.e. 86.0% ayes, and 14.0% nays. 22.8% of participants agreed to the opinion; "For introduction of this system, earlier is better," 50% reported having an opinion such as, "Will introduce this system in an earliest possible time after correcting problems," 26.3% reported having an opinion such as, "Let's decide the time for introduction of this system after correcting problems first,' and 0.9% reported having an opinion, "it's too early to introduce this system." Specifically, the ratio of ayes on introduction of the system marked 72.8%, and it revealed that a majority of respondents have an opinion such as, "Will introduce this system in an earliest possible time after correcting problems." As means of solutions for the problem regarding the limits of applications that existed in SEA System, factors, such as collecting a wide variety of opinions, securing experts, and faithful implementation, etc. were reported important, and in addition to these factors, respondents revealed having opinions such as, consistent research and development, reflection of public interest, establishment of professional organization, enforcement of after-management service, expanding investments in large, systemizing reference materials, and encouraging public participation, etc. To improve problems involving with present EIA system, it has been identified through this study that SEA is efficient and useful. In order to have SEA introduced successfully, it has been cleared that internalization of effectiveness of environmental cost together with HIA must be accomplished.

THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT (치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향)

  • Choi Jin-Ho;Yang Jae-Ho;Cho Won-Pyo;Lee Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.432-442
    • /
    • 2006
  • Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.

EVALUATION OF THE ACCURACY OF FIXTURE-LEVEL IMPRESSION TECHNIQUE FOR INTERNAL CONNECTION IMPLANT USING CLINICAL METHODS (임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가)

  • Choi Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.421-431
    • /
    • 2006
  • Statement of problem : Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression technique in internal connection implant system. Purpose: This study evaluated the accuracy of splinted fixture-level impression technique using clinical methods and the effect of internal hex on fit of superstructure in internal connection implant system (Astra Tech). Material and method : Two metal master frameworks made from two abutments (Cast-to Abutment ST) each for parallel and divergent conditions and a corresponding. passively fitting, dental stone master cast with four future replicas (Fixture Replica ST) were fabricated. Ten dental stone casts were made with vinyl polysiloxane impressions from the master cast by acrylic resin splinted fixture-level impression technique. To evaluate the accuracy of impression technique, the fit of master frameworks for test models was evaluated using screw resistance test (SRT) and one-screw test. The results of SRT were recorded as SRT values from grade 1 to grade 5 by 1/4 turn. And to evaluate the effect of hex on fit of superstructure, the same tests were performed after removing hexes of master frameworks. Results: 1. There was only one case (2.5%) showing SRT value of test model below ade 2 in total before and after removing hexes of master frameworks. And, by removing hexes. SRT values decreased in only one test model (5%) and did not change in 17 test models (85%). 2. SRT values of the 1$^{st}$ screws were grade 2 in 80% of cases before, and grade 1 in 80% of cases after removing hexes. And, by removing hexes, SRT values decreased in 72.5% of cases. 3. SRT values of the 2$^{nd}$ screws were grade 3 in 85% of cases before, and grade 3 in 95% of cases after removing hexes. And, by removing hexes, SRT values did not change in 85% of cases. 4. There were only 2 cases regarded as acceptable fit by one-screw test, and SRT values of 2$^{nd}$ screws of both cases were grade 2. Conclusion. Within the limitations of this study, future-level impression of internal connection implant system is considered to obtain inaccurate working cast, even using acrylic resin splinted impression technique. And, it is considered to be unable improve the fit to remove the hexes of implant restoration.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

A STUDY ON THE SOLUBILITY AND THE WATER SORPTION OF VARIOUS RESIN CEMENTS (수종의 레진 시멘트의 용해도와 수분흡착에 관한 연구)

  • Hwang Yu-Jin;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • Statement of problem. Among the physical properties of adhesion luting cement, the aspect that requires the most important factor is the degree of solubility and water sorption. Dissolution or an inadequate due to excessive water sorption inside the oral cavity compromises the while concurrently increasing the susceptibility to secondary dental caries. Susceptibility to dissolution and difficulty of removing remnant cement from the gingival sulcus have hindered the use of dental resin cement in the clinical practice, but the improved characteristics of newer generation resin cements have interest in and enabled resin cements to be widely used in adhesion of fixed prosthesis, such as laminate veneers and all-ceramic crowns. Purpose. The purpose of this study is to compare and analyze the degrees of solubility and water sorption of a variety of resin cements widely used for clinical purposes with different curing methods. Material and methods. Self-curing resin cements, $Avanto^{(R)}$, $C&B^{TM}$ CEMENT and Superbond C&B cements comprised group 1, 2 and 3. The dual-curing resin cements $Panavian^{TM}$ F, $Calibra^{(R)}$ and $Variolink^{(R)}$ II were divided into groups 4, 5, and 6, respectively. The investigation was carried out using disc-shaped specimens as specified by ANSI/ADA Specification No. 27. The degree of water sorption, water solubility and lactic acid solubility of each test group was analyzed statistically leading to the following conclusion. Results. The degree of water sorption was shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. There were significant differences between the water sorption of each group. Results of the degree of water solubility were shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. Statistically significant differences were found between each group, with the exception of groups 1 and 3. Finally, the degree of lactic acid solubility was found to increase in the following order : group 6,5,4,2,3 and 1. Significant differences were found between each group. In general dual-curing resin cements displayed substantially lower values than self-curing resin cements with regard to water sorption, water solubility, and lactic acid solubility. Conclusions. From the results of this study, dual-curing resin cements show a significantly lower degree of water sorption and solubility than their self-curing counterparts. Clinically, when selecting resin cements, the product with a lower degree of water sorption and solubility are preferred. The results of this study indicate that the use-of dual-curing resin cements is preferable to self-curing cements.

A STUDY ON THE OCCLUSAL PLANE AND THE VERTICAL DIMENSION IN KOREAN ADULTS WITH NATURAL DENTITION (한국 성인 유치악자의 교합평면 및 수직고경에 관한 연구)

  • Park Jeong-Hyeong;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.41-51
    • /
    • 2005
  • Statement of problem. Anatomic landmarks have been used in the orientation of occlusal plane and the determination of vertical dimension for edentulous patients. Such as labial vestibules of anterior region and hamular notches, retromolar pads of posterior region are very useful anatomic landmarks for fabrication of occlusion rim because they are to be identified on master casts. Therefore, if average distances between landmarks of maxillae and mandible in dentate subjects are measured and applied, not only occlusal plane but also vertical dimension can be established initially. Purpose. The purpose of this study is to measure vertical distances between anatomic landmarks and to present a guide to the orientation of occlusal plane and the determination of vertical dimension of edentulous patients. Material and method. Upper and lower border-molded casts were made in 93 Korean dentulous subjects, mean age 25 years. Incisal edges of central incisors, bottoms of labial vestibules, hamular notches and the half level of retromolar pads were marked on casts. Measurements of vertical distances from incisal edge of central incisor to the bottom of labial vestibule, between upper and lower bottoms of labial vestibules, from hamular notch to retromolar pad and from hamular notch to the occlusal plane established by the incisal edge of maxillary central incisor and mesiopalatal cusps of both maxillary first molars were made on each cast. Results and conclusion. 1. The mean distance from the incisal edge of central incisor to the bottom of labial vestibule was 20.8mm(SD 1.7) on upper casts and 17.3mm(SD 1.4) on lower casts. 2. The mean distance between both bottoms of labial vestibules of upper and lower casts was 35.0mm(SD 2.7). 3 The mean distance from hamular notch to the half level of retromolar pad was 5.0mm(SD 1.3). 4. The mean distance from hamular notch to occlusal plane was 7.9mm(SD 1.5). 5. Distances from incisal edge of central incisor to labial vestibule on lower casts(P<0.01) and from hamular notch to retromolar pad(P<0.0001) were greater in male than in female.

THE INFLUENCE OF PORCELAIN LAYER THICKNESS AND COLOR ON THE FINAL SHADE OF CERAMIC RESTORATIONS (도재층의 두께와 색이 도재수복물의 최종 색조에 미치는 영향)

  • Seong Dong-Hwan;Lee Im-Gi;Sohng Jin-Won;Bok Won-Mi;Ahn Seung-Geun;Park Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.587-598
    • /
    • 2005
  • Statement of problem: Ceramic restorations should be made of porcelain layers of different opacity, shade, and thickness in order to provide a natural appearance. Lithium disilicate glass-ceramic system has superior color reproducibility, because it uses the ceramic ingot which is similar to teeth shade and uses the staining technique and layering technique. However, staining technique has a fault of discoloration. Also, porcelain is divided core and dentin layer, it is not enough to study about the influence of porcelain layer thickness and shade on the shade of ceramic restorations. Purpose: The purpose of this study was to evaluate the influence of porcelain layer thickness and color on the final shade of ceramic restorations. Materials and method: The CIE $L^*a^*b^*$(CIELAB) values of 72 assembled specimens, each consisting of 3 discs (enamel porcelain 0.2 mm/dentin porcelain -1.2, 0.9, 0.7, 0.5 or 0.3 mm/ceramic core -0.3, 0.5, 0.7, 0.9 or 1.2 mm, diameter is 1.0 mm) were evaluated with a spectrophotometer (Model Chromaview 300, Spectron Tech Co, Korea) for the shade A1, A2, A3 and A4. Distilled water (refractive index: 1.7) was used to attain optical contact between the layers. White, white gray, and white brown backgrounds were used to assess the influence of the background on the final shade. And the mean color difference value$({\Delta}E)$ was calculated. Results and conclusion: The results obtained from this study were as follows. 1. There was a significant correlation between the thickness ratio of the ceramic core/dentin porcelain system and $L^*,\;a^*\;and\;b^*$ values when the total thickness of specimen combination was smaller than 1.4 mm(P<0.05). 2. The specimen which the ceramic core thickness was more than 0.7 mm had the best masking effect against background colors. 3. The mean color difference value$({\Delta}E)$ is smaller than 2 $({\Delta}E<2)$ when the ceramic core thickness was larger than 0.7 mm and the total thickness of specimen was more than 1.4 mm.

THREE-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT RESTORATION USING DIFFERENT FIXTURE AND ABUTMENT SCREW DIAMETERS (단일치 임플랜트 지지 보철물에서 고정체와 지대주 나사 직경의 차이에 따른 삼차원 유한요소법적 응력 분석)

  • Kwon Joo-Hong;Choi Min-Ho;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.105-119
    • /
    • 2005
  • Statement of problem. As the effects of the various diameters of fixture and abutment screw on stress distribution was not yet examined, this study focused on the different design of single implant restoration using three dimensional finite element analysis. Purpose. This study was to compare five different fixture-abutment combinations for single implant supported restorations with different fixture and abutment screw diameters. Material of methods. The five kinds of finite element models were designed by 3 diameter fixtures ($\oslash$3.3, 3.75, 5.0 mm) with 3 different abutment screws $\oslash$1.5, 1.7, 2.0 mm). The crown for mandibular first molar was made using UCLA abutment according to Wheeler's anatomy. 244 N was applied at the central fossa with two different loading directions, vertically and obliquely (30$^{\circ}$) and at the buccal cusp vertically. Maximum von Mises stresses were recorded and compared in the supporting bone, crowns, fixtures, and abutment screws. Results. 1. The stresses in supporting bone and implant-abutment structure under oblique loading were greater than those under vertical or offset loading. The stresses under vertical loading were the least among 3 loading conditions regardless of the implant and abutment screw diameters. 2. The stresses in the narrow implants were greater than the wider implants. The narrow implant with narrow abutment screw showed highest stresses in the lingual crest, but the narrow implant with standard abutment screw showed highest stress in abutment screw. 3. The stresses of abutment screws were influenced by the diameter of fixtures and loading conditions. The wide implants showed least difference between two different abutment screw diameters. Conclusions. The wide implants showed lesser stresses than the narrow implants and affected least by the different abutment screw diameters. The narrow implants with standard abutment screw showed highest stresses in the lingual bony crest under oblique loading.