• 제목/요약/키워드: Probe unit

검색결과 138건 처리시간 0.033초

정전형 8중극 비점수차 보정기가 내장된 극초소형 마이크로컬럼의 구조 설계 연구 (Study on the Structural Design of an Ultra-miniaturized Microcolumn with a Built-in Electrostatic Octupole Stigmator)

  • 오태식
    • 반도체디스플레이기술학회지
    • /
    • 제22권3호
    • /
    • pp.52-61
    • /
    • 2023
  • We designed a novel ultra-miniaturized microcolumn structure having an stigmator to significantly improve throughput per unit time, which is the biggest disadvantage of microcolumns. We adopted the structure of the stigmator in the form of an electrostatic octupole electrode, and used an electrostatic quadrupole deflector with a relatively simple structure considering the increase in wiring due to the introduction of the stigmator. We have dramatically reduced the effect of astigmatism that occurs when the electron beam probe is scanned to the periphery of the target by introducing the stigmator between the control electrode and the deflector. As our numerical analysis simulation results, the field of view obtained as a result of this study is about 46.3% improved compared to our previous study, and the electron beam probe size of less than 10 nm was achieved in the entire field of view.

  • PDF

프로브 자전거 센서자료를 이용한 자전거 주행안전성 및 이동성 통합평가기법 개발 (A Methodology for Evaluating Cycling Safety and Mobility using Probe Bicycle Sensor Data)

  • 주신혜;오철
    • 대한교통학회지
    • /
    • 제30권3호
    • /
    • pp.43-55
    • /
    • 2012
  • 자전거는 비동력 무탄소 교통수단으로써 지속가능한 녹색교통수단으로 각광받고 있으며 자전거이용활성화를 위해서는 빠르고 쾌적하며, 안전한 자전거 주행환경을 제공하여 자전거가 가지고 있는 제약을 극복하여 보다 중요한 교통수단으로서의 기능을 할 수 있도록 해야한다. 따라서 본 연구에서는 자전거 모니터링의 일환으로 주행환경 평가시나리오 및 관성센서 및 자전거 속도계가 장착된 프로브자전거를 활용한 자전거 주행환경 평가기법을 제시하였다. 또한 제시된 평가기법은 신뢰성 분석기법인 FTA(Fault Tree Analysis)이론을 적용하여 자전거 주행안전성(CSI)과 주행이동성(속도)을 동시에 평가할 수 있는 통합평가지표를 제시함으로써 실효성이 높을 것으로 판단된다. 본 연구의 결과는 GPS와 관성센서가 통합된 자전거 전용단말기를 개발하여 공공자전거 시스템의 구성요소로 발전시킨다면 보다 지능적인 자전거 교통 모니터링이 가능할 것으로 기대된다.

Laser Doppler flowmeter를 이용한 치수혈류 측정 (MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER)

  • 반태환;이재상;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.560-569
    • /
    • 1999
  • 치수생활력이란 치수내의 혈관의 상태를 가리킨다. 치수생활력 측정을 위해서 사용되어져 온 온도검사나 전기치수 검사는 치수신경의 반응에 기초하여 간접적으로 치수의 생활력을 판단하는 방법이다. 따라서 치수생활력의 판단을 위해서 치수생활력의 기본인 치수혈류를 파악할 필요가 있어 laser Doppler flowmeter를 이용하여 치수 혈류를 측정하는 방법이 연구되었다. 본 연구에서는 성인치아에서 치수생활력 검사를 위해 laser Doppler flowmeter를 이용하여 치수혈류를 측정 할 경우 생활력의 판단 근거로 참고할 수 있는 정상혈류 측정치의 기초자료를 마련할 목적으로, laser Doppler flowmeter를 이용하여 성인의 상악 중절치에서부터 제1대구치에 이르기까지 각 정상 치아의 치수혈류를 측정하고, probe 고정용 splint 제작 방법 및 생활치수와 실활치수에 따른 치수혈류 측정치의 차이를 비교, 연구하였다. 22세에서 30세까지 성인 남녀 79명을 대상으로 상악 중 절치에서부터 제1대구치에 이르기까지 laser Doppler flowmeter를 사용하여 치수혈류를 측정하였고, 생활치아에 대한 비교군으로는 실활치아라고 판단되는 치아를 가진 성인 남녀 자원자 5명의 치아 13개도 함께 검사하였다. 혈류 측정 probe고정용 splint제작을 위한 고무인상시 직접법에서는 환자 구강내에서 직접 고무인상을 채득하였고, 간접법에서는 구강내에서 일차 인상을 채득하여 만든 석고모형상에서 probe 위치를 표시한 다음 석고모형상에서 이차적으로 고무인상을 채득하였다. 고무인상에서 치관부에 probe 고정을 위한 hole을 형성하고 probe를 삽입, 고정한 다음 probe를 치아 협면에 적용하였다. Laser Doppler flowmeter에서 안정된 신호가 나타날 때까지 피검자를 10분 이상 동안 안정시켰으며 안정상태 도달 후 각 치아마다 5 분간 지수혈류를 기록하였다. 측정된 치수혈류는 'Perisoft'(Perimed Co., Sweden) 프로그램을 이용하여 컴퓨터에 저장한 후 측정치를 계측하였다. 각 치아간의 실험치 평균의 차이는 일원 변량 분석법(one-way ANOVA) 및 Duncan's Multiple Range test를 이용하여 분석하였으며, 다음과 같은 결과를 얻었다. 1. 상악 중절치에서부터 제1대구치에 이르기까지 시험대상 전 치아에서의 치수혈류 측정치 평균은 9 - 16 Perfusion Unit 사이로 나타났는데, 상악 측절치에서 가장 높게 나타났고, 제1소구치, 제2소구치, 견치, 중절치, 제1대구치의 순으로 높게 나타났다(p<0.01). 2. 상악 6전치에서는 간접인상법으로 제작된 splint 적용군이 직접인상법으로 제작된 splint 적용군에 비해 높은 측정치를 나타내었으나(p<0.01). 소구치 및 대구치에서는 측정치에 있어서 차이를 나타내지 않았다(p>0.05) 3. 생활치아에서는 실활치아에 비해 현저히 높은 측정치를 나타내었고(p<0.01). 측정선의 양상은 심장 박동과 일치하는 파동성 및 율동성을 나타내었다.

  • PDF

수중용 레벨메터의 제작 및 펄스-에코 특성 (Fabrication and Pulse-echo Response of Level-Meter for Underwater)

  • 양윤석;김철한;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.935-937
    • /
    • 1999
  • In this study, 1-3 type composite specimens were fabricated with PZT powders prepared by the molten-salt synthesis method and Eccogel polymer matrix. A virtual level-meter was fabricated with a 1-3 type composite probe and electronic unit for underwater application. There was no difference in values between a virtual and measured level on its level meter.

  • PDF

인디움 제올라이트 A의 안티몬 흡착과 결정구조 (Crystal Structure of Antimony-sorbed Indium-exchanged Zeolite A)

  • 임우택;이현수;허남호
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.375-390
    • /
    • 2003
  • 인디움 (In)으로 완전히 이온교환 된 제올라이트 A (In-A)를 $350^{\circ}C$에서 6일 동안 안티몬(Sb)과 반응시켰다. 생성물은 EPXMA (electron-probe X-ray microanalysis)를 이용하여 관찰하였다. 인디움으로 이온교환 된 제올라이트 A (In-A)에 안티몬 (Sb)을 흡착시켜 얻은 생성물의 결정구조는 $21^{\circ}C$에서 입방공간군 Pm ${\bar{3}}m$으로 단결정 X-선 회절법을 이용하여 결정하였다. 생성물 $In_8Si_{12}Al_{12}O_{48}{\cdot}(In)_{1.35}(Sb)_{0.7}$ ($a=12.111(2){{\AA}}$, $R_1=0.071$, $R_2=0.067$)은 단위세포당 8개의 인디움 양이온들, 1.35개의 인디움 원자들, 그리고 0.7개의 안티몬 원자들을 가지고 있었다. 단위세포 1 ($In_8-A{\cdot}In$, 단위세포의 65%)에는 $(In_5)^{8+}$ 클러스터가 존재하였다. 단위세포 2 ($In_8-A{\cdot}(In)_2(Sb)_2$, 단위세포의 35%)에는 두 개의 $(In_3)^{2+}$ 클러스터와 한 개의 $(In_3Sb_2)^{7+}$ 클러스터가 large cavity 내에서 발견되었다.

A Linear Beacon System Featuring an Internal Deoxyguanine Quencher Allows Highly Selective Detection of Single Base Mismatches

  • Lee, Young-Ae;Hwang, Gil-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.2011-2014
    • /
    • 2010
  • The fluorescence intensity of a single-stranded oligonucleotide containing a fluorene-labeled deoxyuridine $(U^{Fl})$ unit increases by only 1.5-fold upon formation of its perfectly matched duplex. To increase the fluorescence signal during hybridization, we positioned a quencher strand containing a deoxyguanine (dG) nucleobase, functioning as an internal quencher, opposite to the $U^{Fl}$ unit to reduce the intrinsic fluorescence upon hybridization with a probe. From an investigation of the optimal length of the quencher strand and the effect of the neighboring base sequence, we found that a short strand (five-nucleotide) containing all natural nucleotides and dG as an internal quencher was effective at reducing the intrinsic fluorescence of a linear beacon; it also exhibited high total discrimination factors for the formation of perfectly matched and single base-mismatched duplexes. Such assays that function based on clear changes in fluorescence in response to single-base nucleotide mutations would be useful tools for accelerating diagnoses related to various diseases.

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF

CNC 공작기계의 열변형 오차 보정 (I) - 보정장치 기초실험 - (Compensation of Thermal Error for the CNC Machine Tools (I) - The Basic Experiment of Compensation Device -)

  • 이재종;최대봉;곽성조;박현구
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.453-457
    • /
    • 2001
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric and thermal errors of the machine tools. In this study, the compensation device is manufactured in order to compensate thermal error of machine tools under the real-time. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to compensate thermal characteristics under several operating conditions, experiments performed with five gap sensors and manufactured compensation device on the horizontal machining center.

  • PDF

폴리머를 이용한 하수관로에서의 퇴적물 제거 기법 (Removal Method for a Deposit at Sewerage with Polymer Additives)

  • 전찬열;오율권;황세준
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.153-159
    • /
    • 2002
  • This experimental study is aimed to increasing the velocity in the sewerage and also development of easy removal method for a corrosion and sand in the flow pipe. And the result by the increasing the out flow per unit time, diameter of sewerage pipe is becoming small size, cut down the construction fee and the same time reducing the tubulent flow pattern in the flow pipe. As a result of detected experimental velocity signal from the probe in the test wall surface, reducing the pump power and increasing the out flow unit time. Apparent water velocity decreases as the value of void ratio increases depends on the varies center of pipe.

Traffic Monitoring을 이용한 XG-PON 동적대역할당 알고리즘 (Dynamic Bandwidth Allocation Algorithm of XG-PON using Traffic Monitoring)

  • 홍성학;한만수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.152-153
    • /
    • 2014
  • 이 논문에서는 XG-PON (10-Gbps-capable passive optical network) 시스템에서 ONU (optical network unit)가 전송요청을 OLT (optical line termination)에게 보내지 않는 새로운 동적대역할당 알고리즘을 제안한다. OLT는 ONU의 상향 대역폭 사용량을 monitoring하고 주기적으로 ONU에게 probe용 대역을 할당하여 ONU의 전송허가량을 추측한다.

  • PDF