• Title/Summary/Keyword: Probe length

Search Result 284, Processing Time 0.029 seconds

Characteristics of Friction Stir Lap Welded A5052 with Probe Length (프루브 길이에 따른 A5052 겹치기 마찰교반접합 특성)

  • Ko, Young-Bong;Kang, Chae-Won;Choi, Jun-Woong;Park, Kyeung-Chae
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.6
    • /
    • pp.294-300
    • /
    • 2009
  • The Friction Stir Welding (FSW) has mainly been used for making butt joints in Al alloys. The development of Friction Stir Lap Welding (FSLW) would expand the number of applications. In this study, for effective application on thin aluminum alloy lap joint, non-heat treatment A5052 alloys were joined by FSLW with the length of probe 2.3 mm and 3.0 mm. Investigating the characteristics of joint area showed the results were as below ; When the length of probe was 2.3 mm, good joint area was formed at all welding condition except for 600 rpm-700 mm/min. In the case of 3.0 mm probe length, there was formed good joint area without defects at 1500 rpm-100 mm/min. The width of joint area, position and size of defects were very important factors for FSLW, due to heat input and stirring intensity.

Characteristics of Friction Stir Lap Weldment according to Joining Parameter in 5052 Aluminium Alloy (5052 알루미늄 합금에서 접합변수에 따른 겹치기 마찰교반접합부의 특성)

  • Ko, Young-Bong;Park, Kyeung-Chae
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.5
    • /
    • pp.181-187
    • /
    • 2012
  • The Friction Stir Welding (FSW) has mainly been used for making butt joints in Al alloys. The development of Friction Stir Lap Welding (FSLW) would expand the number of applications. In this study, microstructures and mechanical properties of FSLW in A5052 alloy were investigated under varying rotating speed and probe length. Investigating the characteristics as FSLWed conditions were as below ; Failure Maximum load by shear fracture was increased proportional to the width of joint area, which was increased by input heat, stirring intensity in the case of 2.3 mm probe length. Tensile fracture occurred, and maximum load was determined due to side worm hole of joint area and softening of microstructure in the case of 3.0 mm probe length. In the case of 3.7 mm probe length, material hook and bottom worm hole were appeared at the end interface of joint area. The most sound FSLW condition with no defects was 3.0 mm probe length and 1500 rpm-100 mm/min. No defects were showed in 1500 rpm-100 mm/min and 1800 rpm-100 mm/min, but Vickers microhardness distribution in TMAZ/HAZ which was fracture zone was lower in 1800 rpm-100 mm/min than in 1500 rpm-100 mm/min. In this condition highest tensile strength, 215 MPa (allowable rate 78% of joint efficient) was obtained.

RFLP(Restriction Fragment Length Polymorphism) by Ribosomal RNA and M13 Probes of Clostridum thermocellum Strains (Ribosomal RNA와 M13 probe에 의한 clostridium thermocellum 균주들의 RFLP(Restriction Fragment Length Polymorphism)비교)

  • 이호섭;홍수형;하지홍
    • Korean Journal of Microbiology
    • /
    • v.29 no.3
    • /
    • pp.189-194
    • /
    • 1991
  • The degree of the genetic variations among Clostridium thermocellum ATCC 27405 and the wild type strains was investigated by the mehtod of GC ratio, DNA-DNA hybridization and RFLP (Restriction Fragment Length Polymorphism) patterns by ribosomal RNA and M13 probe. GC ratio and KNA homology values of th three isolates were approximately equal to those of ATCC type strain. The RFLP patterns by the rRNA and M13 probe showed some differences among C. thermocellum ATCC 27405, wild type strains and Clostridium thermohydrosulfuricum ATCC 33223, indicating that the two probes can be useful in subspecies- and apecies-identification.

  • PDF

The Length Control of Carbon Nanotube using Electrochemical Etching (전해에칭을 이용한 탄소나노튜브의 길이 제어)

  • 이준석;권순근;곽윤근;김수현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.167-171
    • /
    • 2004
  • In this paper, we proposed a new method to control the length of carbon nanotube using electrochemical etching. We made a nano probe that was composed of the tungsten tip and multi-wall carbon nanotube. The nano probe was placed on the nano stage and the carbon nanotube on the nano probe was etched in the electrolyte solution with the applied voltage. The overall procedures were done under optical microscope and can be monitored. We can obtain a nano probe with proper length through this procedure.

A Study on the Control of the Length of Carbon-Nano-Tube Probe (탄소나노튜브 프로브의 길이 제어에 관한 연구)

  • Lee, Jun-Sok;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1888-1891
    • /
    • 2003
  • In this paper, we proposed a new method to control the length of carbon nano tube in the single CNT probe. A single CNT probe was composed of a tungsten tip made by the electrochemical etching and carbon nano tube which was grown by CVD and prepared through the sonication. The two components were attached with the carbon tape. Since the length of CNT can not be controlled during the manufacturing, the post process is needed to shorten the CNT. In this paper, we proposed the method of electrochemical process. The process was done under the optical microscope and the results were checked by SEM. The diameter of the carbon nano tube used in this paper was about 130nm because the above process had to be done with the optical microscope. Using the method proposed in this paper, we can control the length of the nano tube tip.

  • PDF

Study on Validity and Reliablity of the Cutoff Probe and Langmuir Probe via Comparative Experiment in the Processing Plasma

  • Kim, D.W.;You, S.J.;You, K.H.;Lee, J.W.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.576-576
    • /
    • 2013
  • Recently, diagnostics of plasma becomes more important due to requirement of precise control of plasma processing based on measurement of plasma characteristics. The Langmuir probe has been used for the diagnostics but it has an inevitable uncertainty and error sources such as incorrect tip length and RF noise. Instead of the Langmuir probe, various diagnostic methods have been developed and researched. The cutoff probe is promising one for plasma density using microwaves and resonance phenomenon at the plasma frequency. The cutoff probe has various advantages as follows; (i) it is simple and robust, (ii) it uses few assumptions, and (iii) it is free from deposition by reactive gas. However, the cutoff probe also has uncertainty and error sources such as gap between tips, tip length, direction of tip plane, and RF noise. In this study, the uncertainty and error sources in manufacturing both probes and in diagnostics process were analyzed via comparative experiment at various discharge conditions. Furthermore, to reveal the user dependence of both probes, three well trained Ph. D students made the Langmuir probe and the cutoff probe, respectively, and it were analyzed. Thought this study, it is established that reliability and validity of the Langmuir probe and the cutoff probe related with not only the intrinsic characteristics of probes but also probe user.

  • PDF

Development of Automatic Visual Inspection System for Micro Needle (미세 탐침의 비전 자동 검사 시스템 개발)

  • Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.16-25
    • /
    • 2008
  • The micro needle means the ultrafine probe of 'Probe Card'. The size of micro needle is so minute that it is difficult to minute that it is difficult to inspect it with eyes. On the other hand it is very critical if there is a defect in micro needle of probe card. In this study, we developed an automatic visual inspection system for finding defect status in probe angle, tip length and diameter. Through the experimental results, we could find that our proposed method is better than human-eyes inspection method in accuracy and inspection speed, and also in robustness to lighting circumstances.

Estimation of Probe Vehicle Penetration Rates on Multi-Lane Streets Using the Locations of Probe Vehicles in Queues at Signalized Intersections (신호교차로 대기행렬 내 프로브 차량의 위치 정보를 활용한 다차로 접근로에서의 프로브 차량 비율 추정)

  • Moh, Daesang;Lee, Jaehyeon;Kim, Sunho;Lee, Chungwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.2
    • /
    • pp.133-141
    • /
    • 2021
  • The probe vehicle penetration rate is a required parameter in the estimation of entire volume, density, and queue length from probe vehicle data. The previous studies have proposed estimation methods without point detectors, which are based on probability structures for the locations of probe and non-probe vehicles; however, such methods are poorly suited to the case of multi-lane streets. Therefore, this study aimed to estimate the probe vehicle penetration rate at a multi-lane intersection and introduce a probability distribution of the queue length of each lane. Although a gap between estimates and observations was found, the estimates followed the trend of observations; the estimation could be improved by the correction factor hereafter. This study is expected to be used as a basic study for the estimation of entire volume, density, and queue length at multi-lane intersections without point detectors.

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography (초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF