• Title/Summary/Keyword: Probe current

Search Result 568, Processing Time 0.023 seconds

position marking technique for data measured in a scanning hall probe system (스캐닝 홀 프로브 측정 시스템의 데이터 측정 위치 표시 기술)

  • Yoo, Jae-Un;Lee, Jae-Young;Jung, Ye-Hyun;Lee, Sang-Moo;Youm, Do-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.13-15
    • /
    • 2007
  • We employed home-made position marking module in the scanning Hall probe system. The module is composed of two coils of which gap, a, between wires in a coil is $500{\mu}m$. We appiled 10-35mA of current with 15Hz in the coils and recorded ac corresponding magnetic field signal with respect to measuring time while we measured DC field profiles produced due to superconducting film in a perpendicular magnetic field. We calibrate the position, x, of coils using the measuring time and location of the coils in the holder. The error range was about ${\pm}0.1mm$. We test the module as we applied current of 100A and filed of 1kG in the superconducting tape. It was confirmed that there was no interference between superconducting tape and marking coils.

Langmuir probe measurements of electron density and electron temperature in early stage of laser-produced carbon plasma

  • Hong, C.;Chae, H.B.;Lee, S.B.;Han, Y.J.;Jung, J.H.;Cho, B.K.;Park, H.;Kim, C.K.;Kim, S.O.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.32-39
    • /
    • 2000
  • Langmuir probe measurements of electron density, electron temperature and potential are mad in the early stage (<5${\mu}$s) of a laser ablated plasma plume, in which a positive current form positive ions and a electron current are overlapped. The plasma wes produced by focusing the second harmonic, 532 nm, of Q-switched Nd:YAG laser on a high purity carbon target. Then the laser intensity on the target of ~1.6${\times}$10$\^$15/ W/$\textrm{cm}^2$. The measured electron desities and temperatures are ~2${\times}$10/sip 11/ cm$\^$-3/ and -3 eV. In particluar , the phenomenon that the electron temperature decreased and then increased was observed,. It could be well explained that this phenomenon occurred in the process of inverse Bremsstrahlung of free electrons in plasma. Additionally, the plasma potential(>11V) was higher than the published values.

  • PDF

Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique (자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정)

  • Kim, Jung-Ho;Lee, Seung-Muk;Joo, Jin-Ho
    • Progress in Superconductivity
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing (비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션)

  • Lee, Tae-Hun;Cho, Chan-Hee;Lee, Hee-Jong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

Development of New ECT Probe Separating the Permebility Variation Signal in the SG Tube (증기발생기 전열관의 투자율 변화신호 분리를 위한 신형 탐촉자 개발)

  • Park, Duck-Gun;Ryu, Kwon-Sang;Lee, Jeong-Kee;Son, De-Rac
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2008
  • A new ECT probe to separate the ECT signal distortion due to PVC (permeability variation clusters) and ordinary defects created in SG tubes has been developed. The hystersis loops of PVC which are extracted from retired SG (steam generator) tubes of Kori-1 NNP were measured. The tensile tests were performed to identify the mechanism of PVC creation. The conditions detecting the PVC created in 56 tubes were investigated using computer simulation, and the signal processing circuits were inserted in the probe for the digital signal transmission. The new Probe can measure and separate the PVC signal which is created in the SG tubes, and also measures the defects in Ni-sleeving part of SG tubes. furthermore the new ECT probe can measure the defects as fast as bobbin probe, and enhance the testing speed as well as reliability of the defect detection of SG tubes.

Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method (전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향)

  • 이복희;엄주홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • In this paper, the effects of the positions of the potential and current probes on the measurements of the ground resistance and potential gradients with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and ground resistance of the measuring probes. The ground resistance is calculated by applying the 61.8% and rule in the fall-of-potential method, and then the potential probe is located on the straight line between the grounding electrode to be measured and the current probe. However, sometimes the grounding electrode to be measured and the measuring probes in on-site test might not be arranged on the straight line with adequate distance because there are building, road block, construction and other establishments. Provided that the grounding electrode to be measured and the measuring probes ar out of position on the straight line or have inadequate distance, the measurement of the ground resistance classically falls into an error and the measured ground resistance should be corrected. Measurements were focused on the grounding electrode system made by the ground rods of 2.4m long. It was found that the suitable separation between the grounding electrode to be measured and the current probe is more than 5 times of the length of the grounding electrode to be measured.

  • PDF

A Technique for Analyzing LSI Failures Using Wafer-level Emission Analysis System

  • Higuchi, Yasuhisa;Kawaguchi, Yasumasa;Sakazume, Tatsumi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.1
    • /
    • pp.15-19
    • /
    • 2001
  • Current leakage is the major failure mode of semiconductor device characteristic failures. Conventionally, failures such as short circuit breaks and gate breakdowns have been analyzed and the detected causes have been reflected in the fabrication process. By using a wafer-level emission-leakage failure analysis method (in-line QC), we analyzed leakage mode failure, which is the major failure detected during the probe inspection process for LSIs, typically DRAMs and CMOS logic LSIs. We have thus developed a new technique that copes with the critical structural failures and random failures that directly affect probe yields.

  • PDF