• Title/Summary/Keyword: Probe Tip

Search Result 218, Processing Time 0.027 seconds

Oxidation Behavior around the Stress Corrosion Crack Tips of Alloy 600 under PWR Primary Water Environment (PWR 1차측 환경에서 Alloy 600 응력부식균열 선단 부근에서의 산화 거동)

  • Lim, Yun Soo;Kim, Hong Pyo;Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.141-150
    • /
    • 2012
  • Stress corrosion cracks in Alloy 600 compact tension specimens tested at $325^{\circ}C$ in a simulated primary water environment of pressurized water reactor were analyzed by analytical transmission electron microscopy and secondary ion mass spectroscopy (SIMS). From a fine-probe chemical analysis, oxygen was found on the grain boundary just ahead of the crack tip, and chromium oxides were precipitated on the crack tip and the grain boundary attacked by the oxygen diffusion, leaving a Cr/Fe depletion (or Ni enrichment) zone. The oxide layer inside the crack was revealed to consist of a double (inner and outer) layer. Chromium oxides existed in the inner layer, with NiO and (Ni,Cr) spinels in the outer layer. From the nano-SIMS analysis, oxygen was detected at the locations of intergranular chromium carbides ahead of the crack tip, which means that oxygen diffused into the grain boundary and oxidized the surfaces of the chromium carbides. The intergranular chromium carbide blunted the crack tip, thereby suppressing the crack propagation.

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.26 no.4
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.

Needle Type of Hybrid Temperature Probe for Both Diagnosis and Treatment of Musculoskeletal Pain Syndrome (근골격계 통증질환의 진단과 치료를 위한 주사바늘형 복합온도 프로브의 개발)

  • Nam, Sung-Ki;Kim, Hyung-Il;Byun, Chang-Ho;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.4
    • /
    • pp.359-364
    • /
    • 2014
  • This paper describes the development of needle type probe that measures temperature and injects medicine for both diagnosis and treatment of musculoskeletal pain syndrome (MPS). The size of trigger points is from several micrometers to millimeter. Therefore, it is required to develop a medical device that is capable of not only finding the trigger points by temperature measurement, but also injecting medicine at the exact location for treatment. To challenge these difficulties, thermocouple was fabricated on the surface of a needle using metal deposition process. Special type of stainless-constantan thermocouple was achieved from the stainless body of a needle itself and deposited constantan metal film. In particular, parylene coating enables to limit the temperature sensitive area to the end of the needle tip. Fabricated needle type probe produces $3.25mV/^{\circ}C$ of thermoelectric sensitivity and compared its performance with commercial T-type thermocouple in animal muscle sample.

Unsteady Wet Steam Flow Measurements in a Low-Pressure Test Steam Turbine

  • Duan, Chongfei;Ishibashi, Koji;Senoo, Shigeki;Bosdas, Ilias;Mansour, Michel;Kalfas, Anestis I.;Abhari, Reza S.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.85-94
    • /
    • 2016
  • An experimental study is conducted for unsteady wet steam flow in a four-stage low-pressure test steam turbine. The measurements are carried out at outlets of the last two stages by using a newly developed fast response aerodynamic probe. This FRAP-HTH probe (Fast Response Aerodynamic Probe - High Temperature Heated) has a miniature high-power cartridge heater with an active control system to heat the probe tip, allowing it to be applied to wet steam measurements. The phase-locked average results obtained with a sampling frequency of 200 kHz clarify the flow characteristics, such as the blade wakes and secondary vortexes, downstream from the individual rotational blades in the wet steam environment.

Modeling and optimal design of monolithic precision XYZ-stage using flexure mechanism (유연기구를 이용한 초정밀 단일체 3축 스테이지의 모델링 및 최적설계에 관한 연구)

  • Shim, Jong-Yeop;Gweon, Dae-Gab
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.868-878
    • /
    • 1998
  • There are recently increasing needs for precision XYZ-stage in the fields of nanotechnology, specially in AFMs(Atomic Force Microscope) and STMs(Scanning Tunneling Microscope). Force measurements are made in the AFM by monitoring the deflection of a flexible element (usually a cantilever) in response to the interaction force between the probe tip and the sample and controlling the force neasyred constant topography can be obtained. The power of the STM is based on the strong distance dependence of the tunneling current in the vacuum chamber and the current is a feedback for the tip to trace the surface topography. Therefore, it is required for XYZ-stage to position samples with nanometer resolution, without any crosscouples and any parasitic motion and with fast response. Nanometer resolution is essential to investigate topography with reasonable shape. No crosscouples and parasitic motion is essential to investigate topography without any shape distortion. Fast response is essential to investigate topography without any undesirable interaction between the probe tip and sample surface ; sample scratch. To satisfy these requirements, this paper presents a novel XYZ-stage concept, it is actuated by PZT and has a monolithic flexible body that is made symmetric as possible to guide the motion of the moving body linearly. PZT actuators have a very fast response and infinite resolution. Due to the monolithic structure, this XYZ-stage has no crosscouples and by symmetry it has no parasitic motion. Analytical modeling of this XYZ-stage and its verification by FEM modeling are performed and optimal design that is to maximize 1st natural frequencies of the stage is also presented and with that design values stage is manufactured.

Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan (2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구)

  • Cho, Jin-Soo;Cho, Lee-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

Scanning Kelvin Probe Microscope analysis of Nano-scale Patterning formed by Atomic Force Microscopy in Silicon Carbide (원자힘현미경을 이용한 탄화규소 미세 패터닝의 Scanning Kelvin Probe Microscopy 분석)

  • Jo, Yeong-Deuk;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.32-32
    • /
    • 2009
  • Silicon carbide (SiC) is a wide-bandgap semiconductor that has materials properties necessary for the high-power, high-frequency, high-temperature, and radiation-hard condition applications, where silicon devices cannot perform. SiC is also the only compound semiconductor material. on which a silicon oxide layer can be thermally grown, and therefore may fabrication processes used in Si-based technology can be adapted to SiC. So far, atomic force microscopy (AFM) has been extensively used to study the surface charges, dielectric constants and electrical potential distribution as well as topography in silicon-based device structures, whereas it has rarely been applied to SiC-based structures. In this work, we investigated that the local oxide growth on SiC under various conditions and demonstrated that an increased (up to ~100 nN) tip loading force (LF) on highly-doped SiC can lead a direct oxide growth (up to few tens of nm) on 4H-SiC. In addition, the surface potential and topography distributions of nano-scale patterned structures on SiC were measured at a nanometer-scale resolution using a scanning kelvin probe force microscopy (SKPM) with a non-contact mode AFM. The measured results were calibrated using a Pt-coated tip. It is assumed that the atomically resolved surface potential difference does not originate from the intrinsic work function of the materials but reflects the local electron density on the surface. It was found that the work function of the nano-scale patterned on SiC was higher than that of original SiC surface. The results confirm the concept of the work function and the barrier heights of oxide structures/SiC structures.

  • PDF

Calibration of a Five-Hole Pressure Probe using a Single Sector Error Interpolation Model (단일영역 오차보간 모델을 이용한 5-Hole Pressure Probe의 교정)

  • O, Se-Yun;An, Seung-Gi;Jo, Cheol-Yeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.5
    • /
    • pp.30-38
    • /
    • 2006
  • A new calibration method for five-hole pressure probe is presented. This method provides accuracies better than those based on the traditional regression method. The calibration algorithm uses a single sector interpolation response surface calculated by comparing the regression curve fits with the actual calibration data. A five-hole pressure probe with hemispherical tip was fabricated and calibrated at Reynolds number of $4.11{\times}10^6$/m and flow angle of ${\pm}48$ degrees. Two data prediction models, the least-square regression and a single sector error interpolation, were evaluated. The comparison of these two calibration methods to a five-hole probe is described and discussed. An evaluation of the calibration accuracy is also given.

Comparison analysis of pain experienced by patients during periodontal examination using thinner versus thicker probes (치주낭 측정시 probe 굵기에 따른 환자의 통증과 측정값의 비교분석)

  • Kim, Soo-Han;Hong, Ki-Seok;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.193-200
    • /
    • 2007
  • During periodontal examination and periodontal recall visit, patients might feel pain. Probing with 0.45mm diameter probe, "overprobing" into connective tissue underlying periodontal pocket could be the primary aspect of pain. The purpose of present study, performed during recall visit, was to compare the levels of pain experienced by patients during periodontal probing using probes with the tip diameter of either 0.45mm or 0.63mm. Twenty patients were enrolled: 3 periodontists each exammined 20 patients at the Dankook university dental hospital. in each patient at six sites per tooth, diagonal maxillary/mandibular quad-rants were probed with 0.45mm diameter and 0.63mm diameter probe. Lower pain responses following probing with the 0.63mm diameter probe as compared to the 0.45mm probe were observed for patients of therapist 2 and the upper VAS quartile Groups(P<0.05). For therapist 1 and 3 groups, no differences were found. Patient worry about the pain while dental treatment procedures. If therapist use 0.63mm diameter probe while periodontal examination and recall visit, the patient's pain and discomfort could be reduced. Therefore, patient will cooperate more during the treatment, which leads to a better result. Dental therapists should make an effort to minimize the degree of discomfort during treatment. Dental therapist periodically should evaluate this part of their skill by asking patients and promote this skill.

Separation of tip from the bipolar radiofrequency system in the arthroscopic surgery - Case Report - (Bipolar radiofrequency system 사용 중 발생한 Tip의 분리 - 증례 보고 -)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Park, Ji-Kang;Bae, Seung-Whan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.66-68
    • /
    • 2008
  • Recently, devices using radiofrequency energy have been developed for arthroscopic soft tissue ablation, cauterization and shrinkage. After ACL reconstruction operation, articular metallic foreign body was found in the post-operative radiographs. It was proven to be the tip of bipolar radiofrequency system after foreign body removal. After that we experienced 2 more cases during the acromioplasty procedure. We requires attention to prevent the separation of the tip from the body in the arthroscopic surgery using bipolar radiofrequency system.

  • PDF