• Title/Summary/Keyword: ProFile

Search Result 131, Processing Time 0.031 seconds

Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals

  • Kirici, Damla;Kustarci, Alper
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.36.1-36.6
    • /
    • 2019
  • Objectives: The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial doublecurvature canals. Materials and Methods: This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results: The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions: In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

A comparison of dimensional standard of several nickel-titanium rotary files

  • Kim, Ki-Won;Cho, Kyung-Mo;Park, Se-Hee;Choi, Ki-Yeol;Karabucak, Bekir;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Objectives: The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials and Methods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at $32{\times}$. Taper and diameter at $D_1$ to $D_{16}$ of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level ($D_1$ to $D_{16}$) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's post-hoc test at 95% confidence level. Results: TF was the only group not conform to the nominal taper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significant difference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.

Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment

  • Tatiana Dias Costa;Elison da Fonseca e Silva;Paula Liparini Caetano ;Marcio Jose da Silva Campos ;Leandro Marques Resende ;Andre Guimaraes Machado;Antonio Marcio Resende do, Carmo
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.1
    • /
    • pp.6.1-6.10
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the corrosion resistance of heat-treated (Reciproc and WaveOne) and non-heat-treated (ProTaper and Mtwo) superelastic nickel-titanium endodontic files when immersed in a 5.25% sodium hypochlorite solution. Materials and Methods: Anodic polarization curves were obtained with potential sweeps that began at the open circuit potential or corrosion potential (Ecorr). The pitting potential (Epit) was identified on the anodic polarization curve as the potential at which a sudden increase in current was observed. The micromorphology of the 28 tested files was analyzed before and after the electrochemical assay using scanning electron microscope (SEM). The data were analyzed using 1-way analysis of variance with the post hoc Bonferroni test (for Ecorr) and the Student t-test for independent samples (for Epit). Results: The mean Ecorr values were 0.506 V for ProTaper, 0.348 V for Mtwo, 0.542 V for Reciproc, and 0.321 V for WaveOne files. Only WaveOne and Protaper files exhibited pitting corrosion, with Epit values of 0.879 V and 0.904 V, respectively. On the SEM images of the ProTaper and WaveOne files, cavities suggestive of pitting corrosion were detected. Conclusions: Signs of corrosion were observed in both heat-treated and non-heat-treated files. Of the evaluated files, WaveOne (a heat-treated file) and ProTaper (a non-heat-treated file) exhibited the lowest corrosion resistance.

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

Influence of root canal curvature on the screw-in effect of nickel-titanium rotary files in simulated resin root canal (모형 레진근관에서 근관의 만곡도가 니켈-티타늄 전동 파일의 screw-in effect에 미치는 영향)

  • Son, Ji-Young;Ha, Jung-Hong;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.374-379
    • /
    • 2010
  • Objectives: Nickel-titanium (Ni-Ti) rotary instruments have some unexpected disadvantages including the tendency to screw-in to the canal. The purpose of this study was to evaluate the influence of root canal curvatures on the screw-in effect of Ni-Ti rotary files. Materials and Methods: A total of 80 simulated root canals in clear resin blocks were used in the study. Canals with curvature of 0, 10, 20 and 30 degrees were instrumented with ProTaper instruments SX, S1, S2 and a ProFile of #25/0.06 to 1.0-2.0 mm beyond the initial point of root curvature. The screw-in force was measured with a specially designed device while canal was instrumented with a ProFile of #30/0.06 at a constant speed of 300 rpm. The data were subjected to one-way ANOVA and Scheffe multiple range test for post-hoc test. Results: Larger degree of canal curvature generated significantly lesser screw-in forces in all groups (p < 0.001). Conclusions: More attention needs to be paid when using rotary instruments in canals with less curvature than canals with more curvatures to prevent or reduce any accidental overinstrumentation.

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using micro-computed tomography

  • Lee, Woo-Jin;Baek, Seung-Ho;Bae, Kwang-Sik
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.597-598
    • /
    • 2003
  • I. Objectives Endodontic success depends on thoroughly cleaned and completely obturated root canal system. Effective cleaning and obturation will be achieved by well shaped canal. Numerous methodologies evaluating the efficacy and safety of canal preparation has been developed and the use of micro-computed tomography(MCT) in endodontic research is one of the latest innovations. This scientific tools could overcome the inherent limitations of other methodologies, and possesses the ability to visualize morphological characteristics in a detailed and accurate manner without destruction of the tooth and offers reproducible data in all three dimensions. The purpose of this study was to determine the optimal master apical file size with less transportation and more efficiency in removing the infected dentin. For this purpose we evaluated the transportation of canal center and change of untouched area after preparation sequentially from #25 file through #40 file with 3 different instruments:Stainless steel(SS) K-type hand instruments(MANI, Japan), ProFile.04 instruments (Dentply Tulsa Dental, USA) and Lightspeed instruments(Lightspeed Technology, San Antonio, USA) using micro-computed tomography.(omitted)

  • PDF

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.

WORKING LENGTH CHANGE BY INSTRUMENTATION ACCORDING TO THE CANAL CURVATURE (만곡근관에서 근관형성에 따른 작업장 변화에 관한 연구)

  • Kim, Byung-Hyun;Kim, Young-Sik;Lee, Young-Kyoo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.623-627
    • /
    • 1999
  • During canal instrumentation of a curved canal, restoring force of endodontic instrument remove more dentin from the inner wall of the curvature. This effect tends to straighten the canal and thus may significantly shorten the working length. This study was to determine the mean reduction in working length after instrumentation according to the curvature. The curvature of mandibular mesial root was determined before instrumentation. 30 canals were divided into 3 groups each 10 on the basis of degree of curvature. Experimental groups as follows. In group 1, canals having curvature from 15 to 20 degrees: in group 2, canals having curvature from 20 to 30degrees; in group 3, canals having curvature above 30 degrees. Experimental teeth in all groups were accessed, and their actual working length determined by passing a size 15 K-file(IAF) just through the minor apical foramen. The canals were sequentially enlarged to size 35 with ProFile .06 series. The change of working length was calculated by measuring the tip of IAF beyond apical foramen by using stereomicroscope. The change of canal curvature following instrumentation were measured using the Schneider technique. The results were as follows. 1. The greatest changes of curvature and working length were observed in the group 3 canals(P<0.05), next were group 2 canals and group 1 canals(P>0.05). 2. Group 1 canals showed a mean reduction in 1.61 degrees and length of 0.12m respectively(P>0.05). 3. Group 2 canals showed a mean reduction in 3.42 degrees(P<0.05) and length of 0.25mm(P>0.05) respectively. 4. Group 3 canals showed a mean reduction in 7.23 degrees(<0.05) and length of 0.64mm respectively(P<0.05).

  • PDF

COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS (모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교)

  • Kum, Kee-Yeon;Lim, Kyoung-Ran;Jung, Il-Young;Lee, Sung-Jong;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.