• Title/Summary/Keyword: Primary hole

Search Result 102, Processing Time 0.025 seconds

The Effects of Coolant Inventory and Noncondensible Gas on the Natural Circulation in a PWR Loop System (PWR루프계통에서 냉각재 재고량 및 비응축성 가스의 자연순환에 미치는 영향)

  • Cha, Jong-Hee;Jin, Yong-Suk
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.308-320
    • /
    • 1989
  • The objective of this work is to investigate the effects of diminished primary coolant inventory and the presence of noncondensible gas during single- and two-phase natural circulation in a PWR loop model. The test model was composed of two loops with a U-tube heat exchanger in each loop. Through a series of tests, it has been confirmed that the two-phase natural circulation flow rates were greatly dependent on primary coolant inventory as previous investigators observed. The primary coolant inventory limit to maintain two-phase natural circulation was found to be the amount of the coolant necessary to keep the waterline of the coolant nozzle hole center in this model. The presence of noncondensible gas impede the single-phase natural circulation, but it did not affect the two-phase natural circulation significantly.

  • PDF

Analysis of Management According to CT Findings in Chronic Subdural Hematoma

  • Kim, Hae-Yoo;Kwon, Soon-Chan;Kim, Tae-Hong;Shin, Hyung-Shik;Hwang, Yong-Soon;Park, Sang-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.96-100
    • /
    • 2005
  • Objective: The brain computed tomography(CT) is an important tool throughout the clinical course of chronic subdural hematoma(CSDH). In CT findings, the density of CSDH is different in each case. We analyze management options and results according to the density of CSDH. Methods: Seventy one patients with CSDH, who had been managed in our institute from August 2001 to December 2003, were reviewed retrospectively. The authors divided the patients into six groups according to the density of hematoma; Group A-hypodense rather than the brain parenchyma, group B-isodense, group C-hyperdense, group D-mixed with hypodense and hyperdense, group E-mixed with isodense and hypodense and group F-mixed with isodense and hypersdense. In each group, the operation method, the duration of the indwelling catheter and prognosis were analyzed. Results: The patients who showed mixed density were 39 and, those who showed single density were 32. All the patients underwent burr hole drainage for the primary choice. There was only two cases that needed additional craniotomy. The average duration of indwelling catheter was $5.40{\pm}1.91$ days. Statistically the duration was not different in each group(p-value<0.05, $x^2$ test). Three cases recurred, one in group C, another in group D, and the last in group E. It had no statistical significance due to low incidence of recurrence. Conclusion: We conclude that burr hole drainage is an acceptable primary treatment option for CSDH even though the density of hematoma is different in every single case.

Photo Catalytic Ability of Acicular Shaped TiO$_{2}$ Rutile Powder in Aqueous Metal-EDTA Solutions

  • Kim, Sun-Jae;chang-Joo choi;Park, Soon-Dong;Hwang, Jong-Sun;Han, Byung-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.2
    • /
    • pp.37-41
    • /
    • 2001
  • Photo catalytic characteristics of nano-sized TiO$_2$ powder with rutile phase produced using homogeneous precipitation process at low temperatures (HPPLT) were compared with those of commercial P-25 powder by Degussa Co. The TiO$_2$ powder by HPPLT showed very higher photoactivity in the removal rate, showing lower pH values in the solution, than the P-25 powder when eliminating metal ions such as Pb and Cu from aqueous metal-EDTA solutions. This can be inferred the more rapid photo-oxidation or -reduction of metal ions from the aqueous solution, together with relatively higher efficiencies in the use of electron-hole pair formed on the surface of TiO$_2$ particle, under UV light irradiation. Also, in the view of the TiO$_2$ particle morphology, compared to the well-dispersed spherical P-25 particle, the agglomerated TiO$_2$ particle by HPPL T consists of acicular typed primary particle with the thickness ranged of 3∼7 nm, which would be more effective to the photocatalytic reactions without electron-hole recombination on the surface of the TiO$_2$ particle under the UV light irradiation. It is, therefore, thought that the higher photo activity of the rutile TiO$_2$ powder by HPPLT in the aqueous solutions resulted from having its higher specific surface area as well as acicular shape primary particle with very thin thickness.

  • PDF

The Classification of U.T Defects in the Pressure Vessel Weld using the Pattern Recognition Analysis (형상인식을 이용한 압력용기 용접부 결함 특성 분류)

  • Shim, C.M.;Joo, Y.S.;Hong, S.S.;Jang, K.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.11-19
    • /
    • 1993
  • It is very essential to get the accurate classification of defects in primary pressure vessel weld for the safety of nuclear power plant. The signal analysis using the digital signal processing and pattern recognition is performed to classify UT defects extracting feature vector from ultrasonic signals. The minimum distance classifier and the maximum likelihood classifier based on statistics were applied in this experiment to discriminate ultrasonics data obtained form both the training specimens (slit, hole) and the testing specimens(crack, slag). The classification rate was measured using pattern classifier. Results of this study show the promise in solving the many flaw classification problems that exist today.

  • PDF

Experimental Study on the Performance of a Forward-Curved Centrifugal Fan for an Automotive Air-Conditioner (자동차 에어컨용 전곡형 원심 송풍기의 공력성능 분석)

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.122-128
    • /
    • 2000
  • Aerodynamic optimization of an automotive air-conditioning blower is a hard task because of the highly complex flow phenomena related to three-dimensional flow separations and the unsteady nature caused by the interaction between primary and secondary air flows throughout the fan. In this paper, an aerodynamic study on a forward-curved centrifugal fan has been carried out Firstly we obtained the fan performance curves versus flow rates showing its unstable nature in the surging operation range. Secondly aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage using a 5-hole pilot probe, at different operating conditions. Surface flow pattern near the cut-off area exhibits similar flow behavior above the best efficiency operating point, although the pressure level increases substantially with the Increase of flow rate. Vorticity in the casing passage flow occurs in all (low rates, downstream from the r-Z plane $\theta$=120 deg., where the position of its core changes with the circumferential location. Although complex, the general flow behavior were common, giving insight in its main aerodynamic features.

  • PDF

Stress Analysis of Steam Generator Row-1 Tubes (증기발생기 제1열 전열관의 응력 해석)

  • Kim, Woo-Gon;Ryu, Woo-Seog;Lee, Ho-Jin;Kim, Sung-Chung
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.25-30
    • /
    • 2000
  • Residual stresses induced in U-bending and tube-to-tubesheet joining processes of PWR's steam generator row-1 tube were measured by X-ray method and Hole-Drilling Method(HDM). The stresses resulting from the Internal pressure and the temperature gradient in the steam generator were also estimated theoretically. In U-bent lesions, the residual stresses at extrados were induced with compressive stress(-), and its maximum value reached -319 MPa in axial direction at ${\psi}=0^{\circ}$ in position. Maximum tensile residual stress of 170MPa was found to be at the flank side at Position of${\psi}=90^{\circ}$, i.e., at apex region. In tube-to-tubesheet fouling methods, the residual stresses induced by the explosive joint method were found to be lower than that by the mechanical roll method. The gradient of residual stress along the expanded tube was highest at the. transition region, and the residual stress in circumferential direction was found to be higher than the residual stress in axial direction. Hoop stress due to an internal pressure between primary and secondary side was analyzed to be 76 MPa and thermal stress was 45 MPa.

  • PDF

A Numerical Study for Design Optimization of Nozzle Injection Angle in Tenter Machine (텐터기 노즐 분사각의 최적설계를 위한 수치해석적 연구)

  • Chun, Du Hwan;Park, Si Woo;Kim, Jung Han
    • Textile Coloration and Finishing
    • /
    • v.25 no.2
    • /
    • pp.134-139
    • /
    • 2013
  • A tenter is very important to dry and heat-set fabrics in textile dyeing and finishing industry. However, the tenter machine typically utilizes more than 80% of all the power in dyeing system, and yet is one of the primary machine which affects quality of fabrics. Therefore, performance optimization of the tenter machine is required to reduce energy consumption and enhance quality of fabrics. To optimize the tenter machine, it is important to maintain the uniform flow rate, which can be obtained by optimizing a nozzle geometry. In this study, emboss hole angle was investigated as main parameter in flow rate uniformity and heat flux efficiency. The analysis results were compared with those acquired from bench-scale dryer test in the laboratory. The tenter machine performance simulated by Computational Fluid Dynamics(CFD) was optimized by controlling emboss hole angle.

EHT data processing and BH shadow imaging techniques

  • Cho, Ilje
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.59.2-59.2
    • /
    • 2019
  • Event Horizon Telescope (EHT) aims to resolve the innermost region to the super massive black hole (SMBH) with its extremely high angular resolution (~20-25 uas) and enhanced sensitivity (down to 1-10 mJy) in concert with the Atacama Large Millimeter/submillimeter Array (ALMA) at 1.3 mm wavelength. This has a great importance as the first observational probe of the black hole shadow which has been theoretically predicted as a ring-like emission affected by the general relativistic effect under a strong gravitational field of SMBH. During the 2017 April 5-11, four nights of EHT observing campaign were carried out towards its primary targets, M87 and $SgrA{\ast}$. To robustly ensure the data processing, independent pipelines for various radio data calibration softwares (e.g., AIPS, HOPS, CASA) have been developed and cross-compared each other. The EHT has also been developing newer interferometric imaging techniques (e.g., eht-imaging-library, SMILI, dynamical imaging), as well as using an established method (CLEAN). With these, the EHT has designed various strategies which will be adopted for convincing imaging results. In this talk, I review how the robustness of EHT data processing and imaging will be validated so that the results can be ensured against well known uncertainties or biases in the interferometric data calibration and imaging.

  • PDF

Experimental Study on the Horseshoe Vortex Systems Around Surface-Mounted Obstacles (평판 위에 부착된 실린더 주위의 말굽와류 시스템에 관한 실험적 연구)

  • 양준모;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1979-1989
    • /
    • 1992
  • An experimental study has been performed to investigate the horseshoe vortex system formed around cylindrical obstacles mounted vertically on the surface over which a boundary layer is formed. To measure the mean velocity of the flow field, a five-hole Pitot tube has been used. In addition, surface static pressure measurements and surface flow visualization were also performed. From the five-hole probe measurements, vorticity distribution was deduced numerically and the streamwise velocity distribution was also examined. To consider the effect of the leading-edge shape on the formation of the horseshoe vortex, a qualitative comparison was made between the three-dimensional flows around a circular cylinder and a wedge-type cylinder. The five-hole probe measurements showed a single primary vortex which exists immediately upstream of the obstacles, and endwall flow visualization showed the existence of a corner vortex. As the vortex passes around the obstacle, the vortex strength is reduced and the vortex core moves radially outward. Due to this horseshoe vortex, the fluid momentum is found to decrease along the streamwise direction. Since the horseshoe vortex formed around a wedge-type cylinder has weaker strength and is confined to a narrower region than that around a circular, the possibility that the secondary flow loss due to the horseshoe vortex can be reduced through a change of the leading- edge shape is proposed.

Measurement and Within-tree Distribution of Larval Entrance and Adult Emergence Holes of Japanese Pine Sawyer, Monochamus alternatus(Coleoptera: Cerambycidae) (솔수염하늘소의 유충침입공과 성충탈출공의 측정과 소나무 내 분포)

  • 정영진;이상명;김동수;최광식;이상길;박정규
    • Korean journal of applied entomology
    • /
    • v.42 no.4
    • /
    • pp.315-321
    • /
    • 2003
  • Larval entrance and adult emergence holes of Japanese pine sawyer (Monochamus alternatus), primary vector of pinewood nematode (Bursaphelenchus xylophilus), were measured in dead pine logs from 1999 to 2002. Their distributions within pine log were also analyzed. More numbers of entrance and emergence holes were distributed on crown than trunk part as 56.2 and 27.7 holes/m$^2$, respectively Higher proportions of entrance (27.5%) and emergence holes (22.4%) were distributed on the log with 8 to 10 cm diameter; the larger or the smaller logs had fewer holes. Surface area of entrance hole was 65.8 $\textrm{mm}^2$ and diameter of emergence holes was 7.0 mm in average. Average depth of pupal chamber was 24.8 mm from surface to the bottom of the chamber, and its volume ranged from 200 to 2.000 ㎣ Average distance between entrance and emergence holes on bark surface was 3.3 cm. Gallery length from the beginning of entrance hole to the end of emergence hole was 46.2 mm.