• Title/Summary/Keyword: Primary frequency control

Search Result 260, Processing Time 0.029 seconds

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • v.87 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

Extracting parameters of TMD and primary structure from the combined system responses

  • Wang, Jer-Fu;Lin, Chi-Chang
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.937-960
    • /
    • 2015
  • Tuned mass dampers (TMDs) have been a prevalent vibration control device for suppressing excessive vibration because of environmental loadings in contemporary tall buildings since the mid-1970s. A TMD must be tuned to the natural frequency of the primary structure to be effective. In practice, a TMD may be assembled in situ, simultaneously with the building construction. In such a situation, the respective dynamic properties of the TMD device and building cannot be identified to determine the tuning status of the TMD. For this purpose, a methodology was developed to obtain the parameters of the TMD and primary building on the basis of the eigenparameters of any two complex modes of the combined building-TMD system. The theory was derived in state-space to characterize the nonclassical damping feature of the system, and combined with a system identification technique to obtain the system eigenparameters using the acceleration measurements. The proposed procedure was first demonstrated using a numerical verification and then applied to real, experimental data of a large-scale building-TMD system. The results showed that the procedure is capable of identifying the respective parameters of the TMD and primary structure and is applicable in real implementations by using only the acceleration response measurements of the TMD and its located floor.

A Study on the Characteristics of New Frequency Controller According to Changing the Frequency Measurement Position of HVDC System (HVDC 시스템의 주파수 신호검출 위치 변경에 따른 새로운 주파수 제어기 특성 연구)

  • Kim Chan-Ki;Han Byoung-Sung;Park Jong-Kwang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.457-467
    • /
    • 2005
  • This paper deals with the new frequency controller of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency controller after the removing of the present synchronous compensators. The simulation methods are the mix of PSCAD/EMTDC and PSS/E, the main system studies are done for the transient state analysis using PSCAD/EMTDC. The study cases are completed involving 3 phase, single phase trip and load tripping events and study plots presented. In conclusion, the new frequency measurement from the AC network gives effective frequency control and dynamic performance.

Virtual Inertial Control of a Wind Power Plant using the Maximum Rate of Change of Frequency (주파수의 최대 변화율을 이용한 풍력단지 가상관성제어)

  • Kim, Dooyeon;Kim, Jinho;Lee, Jinshik;Kim, Yeon-Hee;Chun, Yeong-Han;Kang, Yong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.918-924
    • /
    • 2013
  • In a conventional power system, the frequency is recovered to the nominal value by the inertial, primary, and secondary responses of the synchronous generators (SGs) after a large disturbance such as a generator tripping. For a power system with high wind penetration, the system inertia is significantly reduced due to the maximum power point tracking control based operation of the variable speed wind generators (WGs). This paper proposes a virtual inertial control for a wind power plant (WPP) based on the maximum rate of change of frequency to release more kinetic energy stored in the WGs. The performance of the proposed algorithm is investigated in a model system, which consists of a doubly fed induction generator-based WPP and SGs using an EMTP-RV simulator. The results indicate that the proposed algorithm can improve the frequency nadir after a generator tripping. In addition, the algorithm can lead the instant of a frequency rebound and help frequency recovery after the frequency rebound.

High-Efficiency Non-contact Power Supply System

  • Zheng, Bin;Kwan, Dae-Hwan;Lee, Dae-Sik
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.233-235
    • /
    • 2005
  • Non-contact power supply (NCPS), as a clean and safe energy supply concept has been applying wildly. Comparing with the conventional transformer the non-contact transformer has a large air gap between the long primary winding and the secondary winding. Due to it, the non-contact transformer has increased leakage inductance and reduced magnetizing inductance. So the high frequency series resonant converter has been widly used on the non-contact power supply system for transferring the primary power to the secondary one, from what a high influence voltage can be gained on the secondry coil even though the large air gap exists. However, it still has the disadvantages of the load sensitive voltage gain characteristics when load is changing. In this paper, we propose a fuzzy logic controller to adjust the frequency of the inverter to track the resonat which is changing when the load is change.

  • PDF

Unsteady Analysis for Combustion Characteristics of PRF75 Fuel under HCCI Conditions (균일예혼합 압축착화 조건에서 PRF75 연료의 비정상 연소특성 해석)

  • Oh, Tae Kyun;Lee, Su Ryong
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.4
    • /
    • pp.21-28
    • /
    • 2013
  • HCCI engines have mainly focused on achieving low temperature combustion in order to obtain higher efficiency and lower emission. One of practical difficulties in HCCI combustion is to control the start of combustion and subsequent combustion phasing. The choice of primary reference fuels in HCCI strategy is one of various promising solutions to make HCCI combustion ignition-controlled. The behavior of ignition delay to the frequency variation of sinusoidal velocity oscillation is computationally investigated under HCCI conditions of PRF75 using a reduced chemistry in a counterflow configuration. The second-stage ignition is more delayed as the higher frequency is imposed on nozzle velocity fluctuation whereas the first-stage ignition is not much influenced.

Isolation of Antibiotic-producing Microorganisms Antagonistic to Soilborne Pathogenic Fungi of Bentgrass and Their Antifungal Activity (잔디 토양전염성병원진균에 대한 길항미생물의 분리 및 길항효과)

  • 이용세;전하준;이창호;송치현
    • Korean Journal of Organic Agriculture
    • /
    • v.6 no.1
    • /
    • pp.133-149
    • /
    • 1997
  • Recently, the importance of management and cultivation of grasses has been increased in Korea. Among these cultural practices, the appropriate control of diseases is considered more important than other cultivation techniques such as fertilization and irrigation. The damages of brown patch and large patch caused by Rhizoctonia spp. and Pythium blight caused by Pythium spp. are serious in the major cultivation area of turfgrass in Korea. Since these diseases are difficult to control by agrochemicals, the damages are very serious if these are occured. The periodic spray of agrochemicals, to protect and control these diseases could make some problems of toxicity and environmental pollution as well as rising of non-target diseases. Therefore, the biological methods to control diseases have been required to decrease problems resulted from overuse of agrochemicals, to conserve natural ecosystem, and to control effectively diseases of grasses in the long period. The number of studies about biological control using antagonistic microorganisms have been increased for last half century. However, the application of biological control method has been very limited. In this study, thirteen isolates of R. cerealis, 8 isolates of R. solani and 3 isolates of Phthyn spp. have been isolated from diseased turfgrass in golf course and grass-culture area that have patch and wilting symptoms of zoysia grass and creeping bentgrass. Isolation frequency of R. cerealis and R. solani was high in especially zoysiagrass, while Pythym spp. was isolated from bent grass at low frequency but showed high pathogenicity. Totally, 205 isolates of soil microorganisms were isolated in this study as primary antagonistic microorganism by Herr's triple agar layer plate and dual culture method using rhizosphere of grasses, soil of crop field as the source of antagonistic microorganisms. Among the 205 isolates, 23 isolates were actinomycetes and 182 isolates were bacteria. All of the actinomycetes were isolated by Herr's method. Antagonistic effect of primary isolated microorganisms was tested for in vitro mycelial growth inhibition against pathogenic fungi isolated from grasses and for inhibition of disease occurrence in 24 well tissue culture plate and pot experiment. Then, four isolated of bacteria which are BG23, BG74, BG136 and BG171 were selected as antagonistic microorganisms against soil-born pathogenic fungi of bentgrass.

  • PDF

Analysis and Design of a Bidirectional Cycloconverter-Type High Frequency Link Inverter with Natural Commutated Phase Angle Control

  • Salam, Zainal;Lim, Nge Chee;Ayo, Shahrin Md.
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.677-687
    • /
    • 2011
  • In this paper a cycloconverter-type high frequency transformer link inverter with a reduced switch count is analyzed and designed. The proposed topology consists of an H-bridge inverter at the transformer's primary side and a cycloconverter with three bidirectional switches at the secondary. All of the switches of the cycloconverter operate in non-resonant zero voltage and zero current switching modes. To overcome a high voltage surge problem resulting from the transformer leakage inductance, phase angle control based on natural commutation is employed. The effectiveness of the proposed inverter is verified by constructing s 750W prototype. Experimentally, the inverter is able to supply a near sinusoidal output voltage with a total harmonic distortion of less than 1%. For comparison, a PSpice simulation of the inverter is also carried out. It was found that the experimental results are in very close agreement with the simulation.

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.

Comparison of Effects of Transcutaneous Electrical Nerve Stimulation (TENS) and San-Yin-Jiao (SP6) Acupressure on Primary Dysmenorrhea (경피신경전기자극(TENS)과 삼음교 지압이 원발성 월경통에 미치는 효과 비교)

  • Oh, Yeong-Taek
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.415-424
    • /
    • 2014
  • PURPOSE: This study examined the effect of high-frequency transcutaneous electrical nerve stimulation (TENS) and San-Yin-Jiao (SP6) acupressure on primary dysmenorrhea. Furthermore, the difference in effectiveness between the two methods were compared. METHODS: Twenty-six students participated in this study, and were randomly assigned to a high-frequency TENS group(experimental 1, n=9), a San-Yin-Jiao (SP6) acupressure group(experimental 2, n=9), and no treatment group(control, n=8). They were assessed and treated on the first day of their menstruation. The TENS protocol included applying 20 minutes of stimulation with a frequency of 100Hz, $100{\mu}sec$ pulse width. Four electrodes were placed on the skin 3 cm from midline at T12-L1 and S2-3 paravertebral muscles. San-Yin-Jiao (SP6) acupressure should be applied with the thumb for 10 minutes(8 seconds pressure and 2 seconds rest) on the SP6 acupoint. This procedure should be repeated for the other foot. Dysmenorrheal pain measured two pain assessment tools (VAS, DPT) pre-treatment; immediate post-treatment; 30minutes, 1, 2hours; and 3, 4, 5, 6, 24 hours after the VAS test were added. RESULTS: The results showed significant differences in pain assessments (VAS, DPT) after treatment for subjects of experimental group1 (p<.05) and experimental group2 (p<.05), whereas the between-group comparison found no statistically significant differences. CONCLUSION: This result supports the idea that using two methods could be effective in pain reduction among students who suffered from primary dysmenorrhea.