• 제목/요약/키워드: Primary energy

검색결과 1,766건 처리시간 0.032초

건물의 냉, 난방 부하비율과 HVAC&R 시스템 1차 에너지 소비량의 상관관계분석 및 합리적 설계방안 연구 (Interaction Analysis between Cooling-to-Heating Load Ratio and Primary Energy Consumption of HVAC&R System for Building Energy Conservation)

  • 조진균;김진호;이성재;강호석
    • 설비공학논문집
    • /
    • 제27권3호
    • /
    • pp.113-122
    • /
    • 2015
  • HVAC&R systems account for more than 50% of the energy consumption of buildings. The purpose of this study is to propose an optimal design method for the HVAC&R system and to examine the possibility for the energy conservation of a selected system. The energy demand for cooling and heating is determined by using TRNSYS and HEET. By an interaction between total system efficiency and cooling-to-heating load ratio, the optimal HVAC&R systems will be decided. The results showed that this proposed method is significantly capable of determining optimal system and building design for saving energy.

인지 무선 통신 시스템에서 에너지 제한적 개방 루프 협력 센싱 기법에 대한 연구 (A Study on Performance Evaluation of Energy-Constrained Open-Loop Cooperative Sensing in Cognitive Radios)

  • 노고산;임성묵;왕한호
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.34-39
    • /
    • 2014
  • In cognitive radios, secondary users can use the spectrum exclusively allocated to a primary wireless system if the secondary users detect the spectrum in idle states. Because the secondary users can utilize the idle state of the spectrum, the utilization rate of the spectrum can be improved. The idle states can be detected by using secondary users' sensing schemes. However, the wireless channel environment where secondary users perform the spectrum sensing is not very friendly to secondary users because the signal-to-noise ratio of the received primary signal is very low. Hence, cooperative sensing scheme where more than one secondary user take part in the spectrum sensing is generally used in cognitive radios. In this paper, we investigate the cooperative sensing performance for machine-to-machine communication devices operated by batteries with limited energy. In general, the energy consumed for the spectrum sensing increases as the length of the sensing period and the number of cooperative sensing nodes. Accordingly, even though the total amount of the consumed energy is the same, an energy allocation methodology how to distribute the energy to the sensing period and sensing nodes can achieve the optimum sensing performance, which is numerically analyzed.

Alternative Strategies to Central Heating Ventilation and Air Conditioning

  • Shrestha, Pramen P.;Prgada, Mythili
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.401-407
    • /
    • 2022
  • Central heating, ventilation and air conditioning (HVAC) is one of the largest consumers of energy in the residential sector. This project explores the use of multiple HVAC units and/or Zoning in a single residence to reduce energy loads. The energy consumption data of a detached single-family home using two HVAC units, one primary for the main house and a secondary HVAC for a casita, was collected for the same month for two consecutive years, along with details related to the outdoor temperature and the square footage being air-conditioned by each HVAC. A regression algorithm was trained using the above details to find the relation between the parameters. Next, based on the occupancy and usage patterns, the HVAC was redesigned assuming more area under the secondary HVAC unit. The trained algorithm was then used to make energy usage predictions for the revised primary HVAC area, with the assumption that the secondary HVAC unit was turned off. The results were compared with existing energy usage data. It was determined that there were significant energy savings in the second scenario. It is expected that this study and its findings will help future research projects explore more ideas as alternatives to central HVAC, in improving the economic viability of existing options, and in developing a savings calculation tool that will help consumers make informed decisions on their best alternatives to central HVAC.

  • PDF

A Review of Ocean Wave Power Extraction; the primary interface

  • Nik, W.B. Wan;Muzathik, A.M.;Samo, K.B.;Ibrahim, M.Z.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권2호
    • /
    • pp.156-164
    • /
    • 2009
  • This paper aims to describe the importance of data, data collection methods, parameters to estimate the potential of wave energy and environmental impacts. The technical and economical status in wave energy conversion is outlined. Power and energy efficiency relationships are discussed. Many different types of wave-energy converters have been detailed. The progress in wave energy conversion in Malaysia is reviewed.

Joint Channel Coding Based on Principal Component Analysis

  • Hyun, Dong-Il;Lee, Dong-Geum;Park, Young-Cheol;Youn, Dae-Hee;Seo, Jeong-Il
    • ETRI Journal
    • /
    • 제32권5호
    • /
    • pp.831-834
    • /
    • 2010
  • This paper proposes a new joint channel coding algorithm based on principal component analysis. A conventional joint channel coder using passive downmixing undergoes a reduction of both the primary-to-ambient energy ratio (PAR) of the downmix signal and the panning gain ratio of the primary source. The proposed system preserves the PAR of the downmix signal by using active downmixing which reflects spatial characteristic. The proposed system also improves the accuracy of the panning gain ratio estimation. Computer simulations and subjective listening tests verify the performance of the proposed system.

원전 일차계통 HyBRID 제염공정 발생 폐액 내 불순물 제거 및 분해 (Removal and Decomposition of Impurities in Wastewater From the HyBRID Decontamination Process of the Primary System in a Nuclear Power Plant)

  • 은희철;정준영;박상윤;박정순;장나온;원휘준;심지형;김선병;서범경
    • 방사성폐기물학회지
    • /
    • 제17권4호
    • /
    • pp.429-435
    • /
    • 2019
  • 원전 일차계통 HyBRID 제염공정에서 발생되는 제염폐액에는 황산이온과 방사성 핵종을 포함한 금속이온 및 발암성 물질의 하이드라진을 포함하고 있어 이를 안전한 수준으로 처리할 수 있는 기술개발이 필요하다. 본 연구에서는 모의 제염폐액내 황산 및 금속이온의 제거와 하이드라진의 분해시험을 실시하여 황산이온, 금속이온 및 하이드라진을 효과적으로 제거할 수 있는 HyBRID 제염폐액 처리공정을 도출하였으며, 1 L 규모에서의 반복실험과 Pilot 규모(300 L/batch)에서의 평가시험을 통해 도출한 HyBRID 제염폐액 처리공정의 성능 재현성과 적용성을 검증하였다.

Spatial Correlation-based Resource Sharing in Cognitive Radio SWIPT Networks

  • Rong, Mei;Liang, Zhonghua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권9호
    • /
    • pp.3172-3193
    • /
    • 2022
  • Cognitive radio-simultaneous wireless information and power transfer (CR-SWIPT) has attracted much interest since it can improve both the spectrum and energy efficiency of wireless networks. This paper focuses on the resource sharing between a point-to-point primary system (PRS) and a multiuser multi-antenna cellular cognitive radio system (CRS) containing a large number of cognitive users (CUs). The resource sharing optimization problem is formulated by jointly scheduling CUs and adjusting the transmit power at the cognitive base station (CBS). The effect of accessing CUs' spatial channel correlation on the possible transmit power of the CBS is investigated. Accordingly, we provide a low-complexity suboptimal approach termed the semi-correlated semi-orthogonal user selection (SC-SOUS) algorithm to enhance the spectrum efficiency. In the proposed algorithm, CUs that are highly correlated to the information decoding primary receiver (IPR) and mutually near orthogonal are selected for simultaneous transmission to reduce the interference to the IPR and increase the sum rate of the CRS. We further develop a spatial correlation-based resource sharing (SC-RS) strategy to improve energy sharing performance. CUs nearly orthogonal to the energy harvesting primary receiver (EPR) are chosen as candidates for user selection. Therefore, the EPR can harvest more energy from the CBS so that the energy utilization of the network can improve. Besides, zero-forcing precoding and power control are adopted to eliminate interference within the CRS and meet the transmit power constraints. Simulation results and analysis show that, compared with the existing CU selection methods, the proposed low-complex strategy can enhance both the achievable sum rate of the CRS and the energy sharing capability of the network.

서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석 (A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul)

  • 김성범;오병칠;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제36권6호
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.