• Title/Summary/Keyword: Primary Switch System

Search Result 42, Processing Time 0.025 seconds

A New High-Efficient Interleaved Converter for Low-Voltage and High-Current Power Systems (저전압 고전류 사양에 적합한 고효율 인터리브 컨버터)

  • Cho, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.600-608
    • /
    • 2016
  • This paper proposes a new high-efficient interleaved phase-shift full-bridge (PSFB) converter for low-voltage and high-current power systems. The proposed converter is composed of three switch-bridges and two transformers in the primary side and two rectifiers in the secondary side. Each transformer handles half of the total power with an interleaved operation, so that the proposed converter has high system reliability, as much as the conventional interleaved PSFB converter. The soft-switching characteristics of the proposed converter are better than those of the conventional converter due to the modulated primary side configuration. The proposed converter represents a single lagging-leg bridge, which has a poor soft switching condition in its operation, while the conventional converter has two lagging-leg bridges in its operation. Therefore, the number of switches having hard-switching conditions is reduced by half in the proposed converter. In addition, the reduced switch counts in the primary side of the proposed converter helps decrease the complexity of the proposed converter compared to that of the conventional converter. The operational principle and analysis are presented in this paper and the characteristics are verified using a PSIM simulation with 3kW server power specification.

An Optical Fiber Perimeter Guard System Using OTDRs (OTDR을 이용한 광섬유 외곽경비시스템에 관한 연구)

  • Chang, Jin-Hyeon;Lee, Yong-Cheol;Shin, Dong-Ho;Oh, Sang-Gun;Lee, Jong-Youn;Jung, Jin-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12B
    • /
    • pp.1236-1243
    • /
    • 2010
  • The perimeter defense system was created and its characteristics were evaluated. It was designed to utilize the fiber sensing device, namely OTDR(Optical Time Domain Reflectometer) which has been used for the maintenance of the optical communication network. An OTDR was constituted by a pulse laser with the nature of 1310nm, +15dBm for the observation of 400 meter optical fence. The high-speed 32-bit processor(S3C2440) has applied to MPU(Main Processor Unit) which helps to improve the performance of OTDR algorithms. Consequently, the maximum error was 0.84 meter on the performance test of the 10km monitoring and the pass criteria of ${\pm}1m$ satisfied in all the sections. The alarm delay time was under 3 sec after detecting the disorder. For the case of secondary trespassing after primary trespassing, the optical switch was installed in OTDR to monitor the secondary trespassing and to measure the multi-point detection. Therefore, this paper shows that the detections of secondary trespassing and multi-point is possible by means of optical switch.

An Integrated Single Stage AC/DC Converter (고전력밀도 단일전력단 교류/직류 컨버터)

  • Phum, Sopheak;Kang, Cheolha;Kim, Eun-Soo;Lee, Young-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.88-90
    • /
    • 2012
  • A study on an integrated single stage AC/DC converter is presented in this paper. The input current can be controlled by the auxiliary winding($L_{aux}$), auxiliary primary winding($N_3$), and the boost inductor($L_B$) which are designed to operate in discontinuous conduction mode(DCM) to reduced the total harmonic distortion(THD) of input current. The auxiliary primary winding($N_3$) is critically selected in order to compress the input capacitor voltage($V_{in}$) as well as to reduce the current stress of the switch(Q). Low total harmonic distortion(THD), low input voltage($V_{in}$) in universal input voltage($V_{AC}$), low current stress at the switching device and high efficiency are the main consideration keys in this design to achieve high performance system with low cost of single stage AC/DC converter. A 30W single stage AC/DC prototype converter is under study.

  • PDF

A Study on Earned Value Management System (EVMS) For Project Using ERP System (ERP 시스템을 이용한 프로젝트 EVMS에 관한 연구)

  • Park, Je-Won;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.145-151
    • /
    • 2010
  • It seems that a primary concern of the project-based company, which provides a large scale product or service over long term period, is to run a successful project through systematic project process control and control costs. One of the typical project control methods is Earned Value Management System(EVMS) which analyses the precess through performance measurement. Even though the EVMS is a highly efficient tool in the managerial aspect, it cannot easily determine the Planned Value(PV), Actual Cost(AC), or Earned Value(EV) due to the indistinct criteria and extensive data. The accurate calculation of AC in particular, is the basic of project management, but most companies record direct personnel expenses or direct expenses only. Since they calculate indirect expenses based on the estimated ratio, it limits the systematic project management that reflects changes in profit and loss of a company. This study introduces a EVMS for project management and its actual case based on EVMS and ERP system which some additional modules are installed for performance measurement. It is expected that this new method enables a company to save time and effort, and also to improve transparency by specifying expense items in detail and to switch quarterly settlement to monthly by reducing the time of calculation.

Development of High Efficiency Boost DC/DC Converter For EV

  • Song, Sung-Geon;Lee, Sang-Hun;Song, Hyun-Jig;Park, Seong-Mi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.415-421
    • /
    • 2014
  • In this paper, reactorless high efficiency boost DC/DC converter for EV is proposed. In proposed converter, improves efficiency because decrease power loss when the switches are turned on/off using zero current switching (ZCS) at all switch of primary full bridge. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer, it reduces system size and expense because of not add special reactor. For validity verification of proposed converter, in the paper implements simulation using PSIM and perform experiment by making 5KW DC/DC converter. In experimental results, efficiency of proposed converter conformed superiority.

A Study on the Loss Analysis for the Phase-Shaft Full-Bridge Converter (위상이동 방식 Full-Bridge 컨버터의 손실 분석에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Lee, Eun-Young;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.157-162
    • /
    • 2003
  • This paper presents the loss analysis of Phase-Shift Full-Bridge Converter. Full-Bridge DC/DC Converter presented in this paper used a phase shift control in the primary side to achieve ZVS (Zero-Voltage-Switching) for main switch. Phase-Shaft Full-Bridge converter have an effect on the high power system. This paper analyses the loss of each component and the various losses in the circuit assessed. The result of the analysis are verified using 2.5kW, 50kHz prototype.

  • PDF

A Preceding Study on Drive System of the Ropeless Elevator (로프리스 엘리베이터 구동시스템 선행연구)

  • Kim, Youn-Hyun;Kim, Sol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.402-410
    • /
    • 2014
  • This paper suggests a preceding study to introduce implementing problems and improving direction when commercializing a ropeless elevator. In this study, the implementation of the study of pilot systems in order to produce the ropeless elevator and also build a linear velocity sensor, this system is applied to the speed control experiment was investigated through testing. Speed control test is carried out in all track including a curved section. This study verified the feasibility of the ropeless elevator and its drive controller is good enough to be accepted. This study also extracted many more problems that still need to be improved in the future for commercializing such as the sensor, high-performance controller, precision structures, safety devices, efficiency improvements and so on.

A Study on the Conversion Time to Minimize of Transient Response during Inter-Conversion between Control Laws (제어법칙 간 상호 전환 시 과도응답 최소화를 위한 전환시간에 관한 연구)

  • Kim, Chongsup
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • The inter-conversion between different control laws in flight has a lot of risk. The SWM(Switching Mechanism) including logic and stand-by mode is designed to analyze the transient response of aircraft during inter-conversion between different control laws, based on the in-house software for non-real-time and real-time simulation. The SWM applies the fader logic of TFS(Transient Free Switch) to minimize the transient response of an aircraft during the inter-conversion, and applies the reset '0' type of the stand-by mode to prevent surface saturation due to integrator effect in the disengaged flight control law. The transition time is also important to minimize the objectionable transient response in the inter-conversion, as well as the transition control law design. This paper addresses the results of non-real-time simulation for the characteristics of transient response to different transition time to select the adequate transient time, and the real-time pilot evaluation, using SSWM(Software Switching Mechanism) and HSWM(Hardware Switching Mechanism), which is met for Level 1 flying qualities and assures safety of flight.

Failure Prognostics of Start Motor Based on Machine Learning (머신러닝을 이용한 스타트 모터의 고장예지)

  • Ko, Do-Hyun;Choi, Wook-Hyun;Choi, Seong-Dae;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.85-91
    • /
    • 2021
  • In our daily life, artificial intelligence performs simple and complicated tasks like us, including operating mobile phones and working at homes and workplaces. Artificial intelligence is used in industrial technology for diagnosing various types of equipment using the machine learning technology. This study presents a fault mode effect analysis (FMEA) of start motors using machine learning and big data. Through multiple data collection, we observed that the primary failure of the start motor was caused by the melting of the magnetic switch inside the start motor causing it to fail. Long-short-term memory (LSTM) was used to diagnose the condition of the magnetic locations, and synthetic data were generated using the synthetic minority oversampling technique (SMOTE). This technique has the advantage of increasing the data accuracy. LSTM can also predict a start motor failure.

A Study on Power Conversion System for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환장치에 관한 연구)

  • Kim, Ju-Yong;Jung, Sang-Hwa;Mun, Sang-Pil;Ryu, Jae-Yup;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.10-24
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V]. In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch $S_5\;and\;S_6$ in the secondary switch which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household