• 제목/요약/키워드: Prevention technique

검색결과 828건 처리시간 0.025초

Establishment of a Tm-shift Method for Detection of Cat-Derived Hookworms

  • Fu, Yeqi;Liu, Yunqiu;Abuzeid, Asmaa M.I.;Huang, Yue;Zhou, Xue;He, Long;Zhao, Qi;Li, Xiu;Liu, Jumei;Ran, Rongkun;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • 제57권1호
    • /
    • pp.9-15
    • /
    • 2019
  • Melting temperature shift ($T_m-shift$) is a new detection method that analyze the melting curve on real-time PCR thermocycler using SYBR Green I fluorescent dye. To establish a $T_m-shift$ method for the detection of Ancylostoma ceylanicum and A. tubaeforme in cats, specific primers, with GC tail of unequal length attached to their 5' end, were designed based on 2 SNP loci (ITS101 and ITS296) of the internal transcribed spacer 1 (ITS1) sequences. The standard curve of $T_m-shift$ was established using the standard plasmids of A. ceylanicum (AceP) and A. tubaeforme (AtuP). The $T_m-shift$ method stability, sensitivity, and accuracy were tested with reference to the standard curve, and clinical fecal samples were also examined. The results demonstrated that the 2 sets of primers based on the 2 SNPs could accurately distinguish between A. ceylanicum and A. tubaeforme. The coefficient of variation (CV) of $T_m$- values of AceP and AtuP was 0.07% and 0.06% in ITS101 and was 0.06% and 0.08% in ITS296, respectively. The minimum detectable DNA concentration was $5.22{\times}10^{-6}$ and $5.28{\times}10^{-6}ng/{\mu}l$ samples of AceP and AtuP, respectively. The accuracy of $T_m-shift$ method reached 100% based on examination of 10 hookworm DNA samples with known species. In the clinical detection of hookworm in 69 stray cat fecal sample, the $T_m-shift$ detection results were consistent with the microscopic examination and successfully differentiated between the 2-hookworm species. In conclusion, the developed method is a rapid, sensitive and accurate technique and can provide a promising tool for clinical detection and epidemiological investigation of cat-derived hookworms.

지하공간의 위험성 평가수법에 관한 연구 -지하가 화재, 폭발 방재 대책 중심으로- (A Study on the Risk Assessment Technique of the Underground Space -Focused on Prevention Policy of Fire and Explosion-)

  • 박종근;노삼규
    • 한국화재소방학회논문지
    • /
    • 제15권4호
    • /
    • pp.64-70
    • /
    • 2001
  • 지하공간 중 지하가의 사고 ,사례와 문헌 연구 및 실태를 조사, 검토하고, 운영, 관리 단계에서 위험요인을 추출하여 화재 폭발 안전대책의 평가요소 및 위험성 평가수법을 제시하고자 한다. 또한, 지하가의 대규모화, 심층화, 복합화에 대한특성 항목을 분류하고 7가지 대책의 중요도를 제시하여 지하가 계획단계의 지표로 삼고자 한다.

  • PDF

골-슬개건-골을 이용한 전방십자인대 재건술에서 이식물의 길이 (Graft Length of the Bone-patellar Tendon-bone for Reconstruction of ACL)

  • 김정만
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.55-62
    • /
    • 1997
  • Various surgical techniques has been advocated for reconstruction of anterior cruciate ligament using the bone-patella tendon-bone graft. Recently endoscopic technique provides good clinical results, with minimal skin incision, accurate positioning of the graft to the femoral tunnel, and decreasing wear rate of the graft. But the graft-tunnel mismatch remains problematic in endoscopic technique. The purpose of this paper is to described causes of the graft-tunnel mismatch and to provide important steps to prevent or minimize the graft-runnel mismatch following anterior cruciate ligament while using the endoscopic technique. Our guideline for prevention of the graft-tunnel mismatch are as follows: (1) The tunnel should he positioned closely to isometric point as much as possible. (2) Anterior placement of the tunnel should be avoided. (3) The change of graft length should be within 2mm between flexion and extension position.

  • PDF

Inverse Analysis of Ultrasonic Signals of Ceramics Based on Ultrasonic Self-Compensating Technique

  • Lee Joon-Hyun;Cheng Ansheng
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.185-190
    • /
    • 2006
  • An ultrasonic self-calibrating technique for the characterization of a ceramic which was fabricated by change pressing time during the HIP process has been applied by using the ratio of the reflection and transmission coefficients of normal incidence longitudinal waves. The ratio is self-compensated, in that it is independent of the characteristics for transmission and reception of ultrasound by the transducer and the condition of the couplant. The insensitive direction in parameter space is defined as the direction in which the variation of the ratio to changes of two parameters vanishes. For inverse problem the distribution of minima in an error surface is investigated.

Ultrasound Breast Elastographic Evaluation of Mass-Forming Ductal Carcinoma-in-situ with Histological Correlation - New Findings for a Toothpaste Sign

  • Leong, Lester Chee Hao;Sim, Llewellyn Shao-Jen;Jara-Lazaro, Ana Richelia;Tan, Puay Hoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권5호
    • /
    • pp.2673-2678
    • /
    • 2016
  • Background: It is unclear as to whether the size ratio elastographic technique is useful for assessing ultrasound-detected ductal carcinoma-in-situ (DCIS) masses since they commonly lack a significant desmoplastic reaction. The objectives of this study were to determine the accuracy of this elastographic technique in DCIS and examine if there was any histopathological correlation with the grey-scale strain patterns. Materials and Methods: Female patients referred to the radiology department for image-guided breast biopsy were prospectively evaluated by ultrasound elastography prior to biopsy. Histological diagnosis was the gold standard. An elastographic size ratio of more than 1.1 was considered malignant. Elastographic strain patterns were assessed for correlation with the DCIS histological architectural patterns and nuclear grade. Results: There were 30 DCIS cases. Elastographic sensitivity for detection of malignancy was 86.7% (26/30). 10/30 (33.3%) DCIS masses demonstrated predominantly white elastographic strain patterns while 20/30 (66.7%) were predominantly black. There were 3 (10.0%) DCIS masses that showed had a co-existent bull's-eye sign and 7 (23.3%) other masses had a co-existent toothpaste sign, a strain pattern that has never been reported in the literature. Four out of 4/5 comedo DCIS showed a predominantly white strain pattern (p=0.031) while 6/7 cases with the toothpaste sign were papillary DCIS (p=0.031). There was no relationship between the strain pattern and the DCIS nuclear grade. Conclusions: The size ratio elastographic technique was found to be very sensitive for ultrasound-detected DCIS masses. While the elastographic grey-scale strain pattern should not be used for diagnostic purposes, it correlated well with the DCIS architecture.

The Polymerase Chain Reaction in Diagnosis of Small B-Cell Non-Hodgkin Lymphomas

  • Antoro, Ester Lianawati;Dwianingsih, Ery Kus;Indrawati, Indrawati;Triningsih, FX Ediati;Harijadi, Harijadi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권2호
    • /
    • pp.491-495
    • /
    • 2016
  • Background: Small B-cell non-Hodgkins lymphoma (NHL) is difficult to be distinguished from non-neoplastic reactive processes using conventional haematoxylin-eosin (HE) staining due to different interpretations among pathologists with diagnosis based on morphologic features. Ancillary examinations such as immunohistochemical (IHC) staining are essential. However, negative or doubtful results are still sometimes obtained due to unsatisfactory tissue processing or IHC technique. The polymerase chain reaction (PCR) as a molecular diagnostic technique is very sensitive and specific. Clonality detection of heavy chain immunoglobulin (IgH) gene rearrangement has been widely used to establish diagnosis of B-cell NHL. Aims: To elaborate interobserver variation in small B-cell NHL diagnosis based on morphologic features only and to confirm sensitivity and specificity of the PCR technique as an ancillary method. Materials and Methods: A toptal of 28 samples of small B cell NHL and suspicious lymphoma were interpreted by 3 pathologists in Sardjito General Hospital based on their morphology only. The reliability of assessment and the coefficient of interobserver agreement were calculated by Fleiss kappa statistics. Interpretation results were confirmed with IHC staining (CD20, CD3, Bcl2). PCR was performed to analyze the clonality of IgH gene rearrangement. Results: Interobserver agreement in morphologic evalution of small B cell NHL and chronic lymphadenitis revealed kappa coefficient 0.69 included in the substantial agreement category. The cases were divided into 3 groups based on morphology and IHC results; lymphoma, reactive process and undetermined group. PCR analysis showed 90% sensitivity and 60% specificity. Conclusions: The present study revealed a substantial agreement among pathologists in small B-cell NHL diagnosis. For difficult cases, PCR is useful as complementary method to morphologic and IHC examinations to establish definitive diagnosis.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권18호
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Critical Evaluation of Fine Needle Aspiration Cytology as a Diagnostic Technique in Bone Tumors and Tumor-like Lesions

  • Chakrabarti, Sudipta;Datta, Alok Sobhan;Hira, Michael
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권7호
    • /
    • pp.3031-3035
    • /
    • 2012
  • Background: Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. Methods: The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Results: Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. Conclusion: FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

Comparison of Complications of Peripherally Inserted Central Catheters with Ultrasound Guidance or Conventional Methods in Cancer Patients

  • Gong, Ping;Huang, Xin-En;Chen, Chuan-Ying;Liu, Jian-Hong;Meng, Ai-Feng;Feng, Ji-Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.1873-1875
    • /
    • 2012
  • Objective: To compare the complications of peripherally inserted central catheters (PICC) by a modified Seldinger technique under ultrasound guidance or the conventional (peel-away cannula) technique. Methods: From February to December of 2010, cancer patients who received PICC at the Department of Chemotherapy in Jiangsu Cancer Hospital were recruited into this study, and designated UPICC if their PICC lines were inserted under ultrasound guidance, otherwise CPICC if were performed by peel-away cannula technique. The rates of successful placement, hemorrhage around the insertion area, phlebitis, comfort of the insertion arm, infection and thrombus related to catheterization were analyzed and compared on days 1, 5 and 6 after PICC and thereafter. Results: A total of 180 cancer patients were recruited, 90 in each group. The rates of successful catheter placement between two groups differed with statistical significance (P <0.05), favoring UPICC. More phlebitis and finger swelling were detected in the CPICC group (P <0.05). From day 6 to the date the catheter was removed and thereafter, more venous thrombosis and a higher rate of discomfort of insertion arms were also observed in the CPICC group. Conclusion: Compared with CPICC, UPICC could improve the rate of successful insertion, reduce catheter related complications and increase comfort of the involved arm, thus deserving to be further investigated in randomized clinical studies.

Applicability of Oncoplastic Breast Conserving Surgery in Asian Breast Cancer Patients

  • Lim, Geok-Hoon;Pineda, Lea Angela
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3325-3328
    • /
    • 2016
  • Background: There are limited studies on oncoplastic breast conserving surgery in Asian women. We aimed to determine the applicability and safety of oncoplastic surgery, highlighting the specific circumstances when it will be most useful and compare our preferred technique with the worldwide practice of oncoplastic approaches. Materials and Methods: Breast cancer patients who underwent oncoplastic breast conserving surgery at a single institution from 1st May 2014-31st March 2015 were included. Data on patient demographics, tumor characteristics and the type of oncoplastic surgery performed were collected. Results: Nineteen breast cancer patients were identified. 42.1% of patients had grade I ptosis. The indications for surgery included a large tumor to breast size ratio (52.6%), multifocal/multicentric lesions (36.8%) and asymmetric breasts (10.6%), averting a mastectomy in 89.4%. Round block was the commonest technique in 63% of patients, in contrast to the inverted T pattern most frequently used in renowned institutions in the West. Mean and median tumor size and weight of specimen were 29.4/25mm (11 - 75mm) and 77g/64g (10 - 246g) respectively. Re-excision rate was 10.5%. Complete mastectomy was performed for one patient. One patient developed wound dehiscence which was treated conservatively. Cosmetic outcome was rated as excellent/good by 94.7% of patients. The patients remained clinically well after a median 16 months follow up. Conclusions: Oncoplastic breast conserving surgery is useful in a specific subgroup of Asian patients with a relatively small breast volume and minimal ptosis. Round block was the commonest technique in our series, in contrast to the worldwide utility of oncoplastic techniques. It is oncologically safe and has good cosmetic outcomes.