• Title/Summary/Keyword: Prevention of deterioration

Search Result 161, Processing Time 0.011 seconds

Rock burst criteria of deep residual coal pillars in an underground coal mine: a case study

  • Qiu, Pengqi;Wang, Jun;Ning, Jianguo;Liu, Xuesheng;Hu, Shanchao;Gu, Qingheng
    • Geomechanics and Engineering
    • /
    • v.19 no.6
    • /
    • pp.499-511
    • /
    • 2019
  • The reliability of reinforced concrete structures is frequently compromised by the deterioration caused by reinforcement corrosion. Evaluating the effect caused by reinforcement corrosion on structural behaviour of corrosion damaged concrete structures is essential for effective and reliable infrastructure management. In lifecycle management of corrosion affected reinforced concrete structures, it is difficult to correctly assess the lifecycle performance due to the uncertainties associated with structural resistance deterioration. This paper presents a stochastic deterioration modelling approach to evaluate the performance deterioration of corroded concrete structures during their service life. The flexural strength deterioration is analytically predicted on the basis of bond strength evolution caused by reinforcement corrosion, which is examined by the experimental and field data available. An assessment criterion is defined to evaluate the flexural strength deterioration for the time-dependent reliability analysis. The results from the worked examples show that the proposed approach is capable of evaluating the structural reliability of corrosion damaged concrete structures.

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

Factors Influencing Cognitive Impairment in Elders with Dementia Living at Home (재가치매노인의 인지장애 영향 요인)

  • Ha, Eun-Ho;Park, Kyung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.3
    • /
    • pp.317-327
    • /
    • 2011
  • Purpose: The purpose of this study was to contribute data toward prevention from advancing dementia and also prevention of deterioration in cognitive impairment by constructing an optimal prediction model and verifying factors influencing cognitive impairment in elders with dementia who reside at home. Methods: The participants in this study were 351 elders who were registered at dementia day care centers in 11 regions of Metropolitan Incheon. Collected data were analyzed using SPSS Statistics 17.0 and SAS 9.1. Bootstrap method using the Clementine program 12.0 was applied to build an optimum prediction model. Results: Gender and education (general characteristics), alcohol, urinary/fecal incontinence, exercise, weight, and ADL (state of health), and depression (psychological state) were found to have an affect on cognitive impairment in these elders. Conclusion: Study results indicate nine key factors that affect cognitive impairment of elders with dementia who reside at home and that could be useful in prevention and management nursing plans. These factors could also be used to expand the role of nurses who are working in community day care centers, and can be applied in the development and provision of various programs to aid retention and improve cognitive function as well as preventing deterioration of cognition.

The Influence of Family Economic Deterioration caused by COVID-19 on Mental Health among Adolescents in Grandparent-headed Families (코로나19로 인한 가정경제 악화가 조손가정 청소년의 정신건강에 미치는 영향)

  • Chang, Hae-Lim;Lee, RaeHyuck
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.651-659
    • /
    • 2022
  • The purpose of this study is to examine the influence of family economic deterioration caused by COVID-19 on mental health among adolescents in grandparent-headed families. For the purpose, this study used raw data from the 16th Korea Youth Risk Behavior Survey constructed by the Korea Disease Control and Prevention Agency in 2020 and analyzed the influence of family economic deterioration caused by COVID-19 on anxiety, stress, depression, and suicidal ideation. The main results regarding research questions are as follows. First, 39% of 589 adolescents in grandparent-headed families experienced family economic deterioration caused by COVID-19. Also, compared with adolescents who did not experience family economic deterioration, those who experienced deterioration showed higher scores of anxiety and stress as well as higher percentages of experiencing depression and suicidal ideation. Second, regression analyses showed that family economic deterioration caused by COVID-19 positively significantly influenced anxiety, stress, depression, and suicidal ideation. Based on the analyzed results, strategies to protect the mental health of adolescents in grandparent-headed families in disaster like COVID-19 were discussed.

Development of New Hybrid Technique of Protective Finishing for the Prevention of Deterioration in Concrete Structures (콘크리트 구조물의 열화방지를 위한 보호마감 복합화 신기술의 개발)

  • 하기주;최민권;신종학;김기태;홍호용;이영범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.739-744
    • /
    • 2001
  • In this study, experimental research was carried out to develop protective finishing, coating materials and new hybrid technique for deteriorating prevention and high durability in concrete structures. It had sufficiently recommended performance for the protective finishing method of concrete structures through testings. This is more progressive double membrane method than single membrane type designed by conventional method. It was found that this hybrid construction method had very excellent performance to improve the durability of existing concrete structures and attain the beauty of concrete structures.

  • PDF

A Study on the Fire Prevention of the Construction Sites (건설현장 화재예방에 관한 연구 - 용접작업을 중심으로 -)

  • Mok, Yun-Soo;Chang, Seong-Rok;Lee, Young-Seob;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.69-75
    • /
    • 2002
  • Current fire safety in the construction sites has developed piecemeal over a considerable period of time. However, the law and regulation of fire safety is insufficient to protect fro in the construction sites. The frequency of fire in the construction sites is very rare but it brings longterm deterioration durability of building structure and large scale industrial calamity. There are many process of works and each work deals with many kind of flammable material, so it is very difficult to find a proper safety fire prevention. This study executed the questionnaire and fire experiment of the welding work to provide effective fire prevention counterplan.

Design of Direct-Current Fuzzy Controller for Mitigating Commutation Failure in HVDC System

  • Gao, Benfeng;Yuan, Kewei;Dong, Peiyi;Luo, Chao;Zhao, Shuqiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1450-1458
    • /
    • 2018
  • Commutation failures can deteriorate the availability of high-voltage direct current (HVDC) links and may lead to outage of the HVDC system. Most commutation failures are caused by voltage reduction due to ac system faults on inverter side. The commutation failure process can be divided into two stages. The first stage, from the occurrence to the clearing of faults, is called 'Deterioration Stage'. The second stage, from the faults clearing to restoring the power system stability, is called 'Recovery Stage'. Based on the analysis of the commutation failure process, this paper proposes a direct-current fuzzy controller including prevention and recovery controller. The prevention controller reduces the direct current to prevent Commutation failures in the 'Deterioration Stage' according to the variation of ac voltage. The recovery controller magnifies the direct current to speed up the recovery of power system in the 'Recovery Stage', based on the recovery of direct voltage. The validity of this proposed fuzzy controller is further proved by simulation with CIGRE HVDC benchmark model in PSCAD/EMTDC. The results show the commutation failures can be mitigated by the proposed direct-current fuzzy controller.

A dynamic procedure for defection detection and prevention based on SOM and a Markov chain

  • Kim, Young-ae;Song, Hee-seok;Kim, Soung-hie
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.11a
    • /
    • pp.141-148
    • /
    • 2003
  • Customer retention is a common concern for many industries and a critical issue for the survival in today's greatly compressed marketplace. Current customer retention models only focus on detection of potential defectors based on the likelihood of defection by using demographic and customer profile information. In this paper, we propose a dynamic procedure for defection detection and prevention using past and current customer behavior by utilizing SOM and Markov chain. The basic idea originates from the observation that a customer has a tendency to change his behavior (i.e. trim-out his usage volumes) before his eventual withdrawal. This gradual pulling out process offers the company the opportunity to detect the defection signals. With this approach, we have two significant benefits compared with existing defection detection studies. First, our procedure can predict when the potential defectors could withdraw and this feature helps to give marketing managers ample lead-time for preparing defection prevention plans. The second benefit is that our approach can provide a procedure for not only defection detection but also defection prevention, which could suggest the desirable behavior state for the next period so as to lower the likelihood of defection. We applied our dynamic procedure for defection detection and prevention to the online gaming industry. Our suggested procedure could predict potential defectors without deterioration of prediction accuracy compared to that of the MLP neural network and DT.

  • PDF

A Phenomenological Studies on Ignition Characteristics of Wires by Local Impact, Over Loading and Overcurrent (국부적 충격, 과부하 및 과전류에 의한 전선의 발화특성에 관한 현상학적 연구)

  • Lee, Jeong-Jin;Lee, Chang-Woo;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.53-60
    • /
    • 2010
  • When a fire breaks out, it is difficult to find out the causes of the fire, because combustible things around fire scene are usually burnt away. Among many causes of fires are electronic wires, this thesis deal with the destroyed sheath of electronic wires caused by fire. It was studied with the use of measurement devices focusing on the distinctions of wires and conductors. This study especially emphasized the process of deterioration, burning pattern, and composition of electronic wire conductor. It also has a phenomenological approach to the distinctive cause of fire by some partial force. The fire prevention methods have been suggested through the analysing results of fire patterns. This study is expected to be a useful material for analyzing various electrical fires.