• Title/Summary/Keyword: Prevent Smoke

Search Result 127, Processing Time 0.028 seconds

An Experimental Study on the Analyze the Pressure Difference in case of Fire in Vertical Space of High-Rise Buildings (고층건축물 수직공간의 화재 시 압력차 분석을 위한 실험적 연구)

  • Huh, Yerim;Kim, HyeWon;Jin, SeungHyeon;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.111-112
    • /
    • 2020
  • As buildings in South Korea become more skyscrapers, the risk of fire is also emerging. Thus, regulations, regulations, and guidelines are being improved to prevent the spread of smoke in the event of a fire in high-rise buildings, but research on smoke flow and pressure distribution in vertical spaces is insufficient. Therefore, in this study, the temperature of each floor in the vertical space according to the size of the fire is measured through the miniature model experiment, and the pressure difference is calculated to establish the basic data for the improvement of the performance of domestic air supply facilities in the future. Thus, a scale model of one-sixth the size of the actual building was produced to measure the temperature, and the pressure difference was derived by substituting the value for the expression. The pressure difference varies depending on the size of the cause of the fire, and it is believed that the differential pressure and conditions of the building should be taken into account before calculating the supply volume for the analysis of the pressure difference according to the size of the cause of the fire in the event of fire.

  • PDF

Comparison of PM2.5 Concentrations before and after Smoke-free Policy in Some Indoor Sports Facilities in Seoul (겨울철 서울시 일부 실내스포츠시설에서 금연정책 실시 전후 PM2.5 농도 비교)

  • Kim, Yoonjee;Lee, Kiyoung;Kim, Seung Won
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.267-274
    • /
    • 2018
  • Objectives: This study examined the impact of a smoke-free policy on indoor air quality at indoor recreation facilities by assessing $PM_{2.5}$ concentrations before and after the implementation of the new policy. Methods: Using real-time monitors, $PM_{2.5}$ concentrations were measured in 50 billiard rooms and 50 golf simulator rooms in Seoul, Korea. The characteristics of the indoor recreation facilities, smoking status, and atmospheric conditions were recorded at the same time.After the enforcement of a smoke-free policy, $PM_{2.5}$ concentrations, installation of smoking room, and smoking status were examined when the facilities were revisited. Results: Almost a half of the billiard rooms and over 80% of golf simulator rooms were located underground. Seventy percent of the billiard rooms and one hundred percent of the golf simulator rooms were equipped with a local exhaust ventilation system. After the implementation of the smoke-free policy, 46% of the billiard rooms and 20% of the golf simulator rooms newly installed a smoking room. In the billiard rooms with a newly-installed smoking room, the $PM_{2.5}$ concentrations decreased from 97.9 to $45.6{\mu}g/m^3$ after the implementation of the smoke-free policy. The same change of 29.0 to $ 26.3{\mu}g/m^3$ was not statistically significant in golf simulator rooms. Indoor $PM_{2.5}$ concentrations were correlated with outdoor $PM_{2.5}$ concentrations, number of smokers, and number of people in the room. Conclusions: The smoke-free policy for indoor recreation facilities was not effective at making the indoor spaces free from second hand smoke. Although a few billiard rooms installed a smoking room, indoor $PM_{2.5}$ concentrations were still higher than those of outdoor $PM_{2.5}$ or atmospheric $PM_{2.5}$. Stricter enforcement of the smoke-free policy should be achieved to prevent secondhand smoke exposure.

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

Study on the Smoke Density Characteristics of Flame Retardant Sol Manufactured by a Sol-gel Method (졸-겔법으로 제조된 방염제졸의 연기밀도 특성에 관한 연구)

  • Cho, Kyeong-Rae;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.11-18
    • /
    • 2017
  • In this study, a non-halogen type organic-inorganic hybrid flame retardant sol, which can impart flame resistance to synthesize silicate of inorganic material and silane coupling agent of organic material by a sol-gel method, were newly manufactured. The addition of flame retardant will prevent loss of life in a fire because smoke from the flammability of interior finishing materials used as the construction materials poses a major danger. The smoke density measurement standard based on flame retardant performance standards, experiments were conducted according to the test equipment and procedures of ASTM E 662. The non-flaming mode experiment and the flaming mode experiment were conducted to confirm the performance of the manufactured flame retardant sol. As a result, the manufactured flame retardant sol improved the physical properties and heat resistance of existing flame retardants, and decreased the smoke production of the fire. Therefore, it may be possible to reduce the damage caused by smoke and expand the applications to various interior finishing materials.

A comparative study on the relationship between estimates of critical velocity and number of jet fans for smoke control - A 'Fire-JF' contour map in road tunnels (임계속도와 제연팬 용량의 상관관계 연구 - 도로터널의 제연팬 특성도 연구)

  • Kim, Hyo-Gyu;Kim, Eun-Soo;Kim, Nam-Young;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.4
    • /
    • pp.269-278
    • /
    • 2004
  • Recently, critical velocity has become a topic to attract most interests from the researchers in the field of tunnel safety. As the minimum velocity to prevent smoke backlayering during a fire, many equations have been proposed so far, and the following three equations are being considered as a standard method in Korea to calculate the capacity of smoke extraction fans. Equation by Kennedy based on Froude number, Tetzner' s equation with additional variable, ${\beta}$ to modify the Kennedy's equation, and the equation with the concept of super critical velocity by Wu are studied in this paper for the comparative purpose. A contour map describing the relationship between the critical velocity and the capacity of smoke extraction fans is proposed as a tool to calculate the number of jet fans for smoke control during a fire in the local tunnels.

  • PDF

Peer Smoking and Smoking-related Beliefs Among College Students in Bangladesh

  • Kamimura, Akiko;Ahmmad, Zobayer;Pye, Mu;Gull, Bethany
    • Journal of Preventive Medicine and Public Health
    • /
    • v.51 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Objectives: Smoking is a significant public health issue in Bangladesh. The purpose of this study was to examine peer smoking and smoking-related beliefs among college students in Bangladesh. Methods: College students at two universities in Dhaka, Bangladesh participated in a self-administered survey in May and June 2017. Results: First, being a current or former smoker is associated with lower levels of beliefs among respondents that they would not smoke even with smoker friends or nervousness, and lower levels of intentions that they would not smoke, while current smokers and former smokers have different smoking-related beliefs. Second, having smoker friends is associated with lower levels of intentions that they would not smoke. Third, higher levels of normative beliefs that it is important not to smoke are associated with higher levels of beliefs that they would not smoke even with smoker friends or nervousness, higher levels of intentions that they would not smoke, and higher levels of avoidance of smoking. Conclusions: Smoking-related beliefs and perceived norms in individuals' social networks are important components in promoting tobacco cessation in Bangladesh. But it is challenging to prevent or intervene in smoking because of the high rates of smoking in this country and the high prevalence of smokers in individuals' social networks. Future studies should examine the most effective interventions to combat smoking in high-smoking social networks, such as using mobile apps or social media, and evaluate the effectiveness of such interventions.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

조사연구-공기흡입 화재탐지설비(ADS)에 대한 고찰

  • Ryu, Eun-Yeol
    • Fire Protection Technology
    • /
    • s.19
    • /
    • pp.17-21
    • /
    • 1995
  • This is to study installation standards of aspirating devices and detectors, which are components of ADS(aspirating fire detection system). The BFPSA(British Fire Protection System Association) code was mainly referred is studying. ADS aspirated air and smoke through the pipe and then checks if there is fire or not. It is now in the limelight because it can early alarm in case of fire and prevent false-alarming.

  • PDF

Study on fire smoke identification method based on SVM and K fold cross verification fusion algorithm (SVM과 K 접힘 교차 검증 융합 알고리즘 기반의 화재 연기 식별 방법 연구)

  • Wang Yudong;Sangbong Park;Jeonghwa Heo
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.843-847
    • /
    • 2023
  • In this paper, we propose a model for detecting efficient fire identification to prevent fires that can lead to various industrial accidents, farmland and large forest fires, with the widespread use of various chemicals and flammable substances as modern technology advances. This paper presents an algorithm that can detect fire smoke in a high-efficiency and short time using images, and an algorithm based on SVM(Support Vector Machine) and K fold cross-verification technologies. By analyzing images, fire and smoke detection algorithms have relatively superior detection performance compared to existing algorithms, and the analysis of fire and smoke characteristics detected in this paper is analyzed stably and efficiently and is expected to be used in various fields that may be exposed to fire risks in the future.

Antigenotoxicity of Vegetable or Fruit Extract against Cigarette Smoke Condensate (담배연기응축물의 DNA 손상작용과 야채 및 과일추출물의 보호효과)

  • Lee, Hyeong-Ju;Heo, Chan;Kim, Nam-Yee;Heo, Moon-Young
    • YAKHAK HOEJI
    • /
    • v.55 no.3
    • /
    • pp.251-259
    • /
    • 2011
  • Cigarette smoke condensate (CSC) is known to be carcinogenic compound. CSC contains many organic compounds such as polycyclic aromatic hydrocarbons (PAHs), and heterocyclic amine compounds (HCAs). Reactive oxygen species (ROS) are also generated and induce oxidative DNA damage during the metabolism of CSC. The rat microsome mediated and DNA repair enzyme treated comet assays together with conventional comet assay were performed to evaluate the mechanisms of CSC genotoxicity. The organic extract of CSC induced oxidative and microsome mediated DNA damage. Vitamin C as a model antioxidant reduced DNA damage in endonuclease III treated comet assay. One of flavonoid, galangin as a CYP1A1 inhibitor, reduced DNA damage in the presence of S-9 mixture. The ethanol extracts of the mixed vegetables (BV) or the mixed fruits (BF) showed potent inhibitory effects against CSC induced DNA damage with oxidative DNA lesions and in the prescence of S-9 mixture. These results indicate that BV and BF could prevent CSC-induced cellular DNA damage by inhibiting oxidative stress and suppressing cytochrome P450 in mammalian cells.