• 제목/요약/키워드: Pressurization of Pipe

검색결과 18건 처리시간 0.024초

펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰 (Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump)

  • 허민웅;민지호
    • 한국압력기기공학회 논문집
    • /
    • 제13권1호
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

자가증기 가압시스템 개발과제 및 모사시험설비 구성 (Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment)

  • 김철웅;유지성;지상연;박재성
    • 한국추진공학회지
    • /
    • 제27권1호
    • /
    • pp.49-57
    • /
    • 2023
  • 자가증기 가압시스템은 저비용, 고신뢰도의 장점으로 차세대 재사용 발사체들의 추진기관에 널리 채택되고 있다. 자가증기 가압시스템은 구조가 간단하나 탱크 내부에서 일어나는 열과 물질의 전달과정에 대한 이해가 필요하다. 이러한 이유로 자가증기 가압시스템의 모사시험을 구상하였다. 모사시험설비는 해외 가압시험설비 사례와 전문가의 자문을 기반으로 구성하였는데, 실제 자가증기 가압시스템과 달리 추진제 탱크를 단열하여 외부환경에 의한 영향을 배제하고자 하였으며, 열과 물질 전달현상의 연구의 편의를 위하여 가압가스 공급라인과 추진제 배관을 분리하였다. 제작된 자가증기가압 모사시험설비를 이용하여 극저온 추진제에서 가압가스의 응축현상, 헬륨을 이용한 가압과 증발된 추진제를 이용한 자가증기가압의 효율성 비교, 그리고 자가증기의 온도에 따른 가압능력을 평가할 수 있다.

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

정지상태 수용액에서 가압과 냉각속도가 과냉각해소에 미치는 영향 (Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution)

  • 김병선;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.850-856
    • /
    • 2007
  • In a supercooled or capsule type ice storage system, aqueous solution (or water) may have trouble with non-uniform dissolution though the system contributes to the simplicity of system and ecological improvement. The non-uniform dissolution increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to observe the supercooled state, a cooling experiment was performed with pressurization to an ethylene glycol(EG) 3 mass% solution in stationary state. Also, the effect of the pressurization from 101 to 505 kPa to the dissolution of supercooled aqueous solution was measured with the dissolution time of the supercooled aqueous solution at a fixed cooling rate of brine. At results, the dissolution of supercooled point decreased as the pressure of the aqueous solution in the vessel increased. Moreover, the dissolution point increased as the heat flux for cooling increased.

Gas-lift를 이용한 극저온 추진제의 재순환 성능에 대한 실험 (Experimental Study on Cryogenic Propellant Circulation using Gas-lift)

  • 권오성;이중엽;정용갑
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.551-554
    • /
    • 2006
  • Inhibition of propellant temperature rising in liquid propulsion rocket using cryogenic fluid as a propellant is very important. Especially propellant temperature rising during stand-by after filling and pre-pressurization can bring into cavitation in turbo-pump. One of the method preventing propellant temperature rising in cryogenic feeding system is recirculating propellant through the loop composed of propellant tank, feed pipe, and recirculation pipe. The circulation of propellant is promoted through gas-lift effect by gas injection to lower position of recirculation pipe. In this experiment liquid oxygen and gas helium is used as propellant and injection gas. Under atmospheric and pressurized tank ullage condition, helium injection flow-rate is varied to observe the variation of recirculating flow-rate and propellant temperature in the feed pipe. There is appropriate helium injection flow-rate for gas-lift recirculation system.

  • PDF

Numerical evaluation of buried composite and steel pipe structures under the effects of gravity

  • Toh, William;Tan, Long Bin;Tse, Kwong Ming;Raju, Karthikayen;Lee, Heow Pueh;Tan, Vincent Beng Chye
    • Steel and Composite Structures
    • /
    • 제26권1호
    • /
    • pp.55-66
    • /
    • 2018
  • In this paper, the response of an underground fibreglass reinforced plastic (FRP) composite pipe system subjected to realistic loading scenarios that may be experienced by an actual buried pipeline is investigated. The model replicates an arbitrary site with a length of buried pipeline, passing through a $90^{\circ}$ bend and into a valve pit. Various loading conditions, which include effects of pipe pressurization, differences in response between stainless steel and fibreglass composite pipes and severe loss of bed-soil support are studied. In addition to pipe response, the resulting soil stresses and ground settlement are also analysed. Furthermore, the locations of potential leakage and burst have also been identified by evaluating the contact pressures at the joints and by comparing stresses to the pipe hoop and axial failure strengths.

DVGW이론에 따른 상수관망의 부식방지에 관한 연구 (Corrosion Reduction Techniques of Pipe Line Net Using DVGW)

  • 추태호;김하일;제성진;옥치율
    • 한국콘텐츠학회논문지
    • /
    • 제6권11호
    • /
    • pp.310-316
    • /
    • 2006
  • 상수도관망에서 발생하는 누수현상은 수자원의 손실뿐만 아니라 압력손실로 인한 추가적 가압 설비의 필요성 및 누수 되는 관로 주변의 토질의 약화 등을 초래하여 관망의 유지관리를 어렵게 하고, 심각한 경제적 손실을 야기하고 있다. 본 연구는 구역고립으로 인한 수압과 유량 등을 상시 모니터링 하여 누수사고의 적극적인 대처와 누수발생을 미연에 방지함으로써 유수율을 향상시킬 수 있다. 실제 구역고립 후 계속되는 수압조절 및 유입유량의 모니터링에 인하여 구역 내 유수율 산정결과 평균 유수율은 88.94%로서 부산광역시 2003년도의 유수율 79.5%보다 9.44% 높게 조사되었다.

  • PDF

DVGW이론에 따른 상수관망의 부식방지를 위한 정수처리방안 (Reduction Techniques of the Pipe Line net Using According to DVGW)

  • 추태호;김하일
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2005년도 추계 종합학술대회 논문집
    • /
    • pp.115-118
    • /
    • 2005
  • 상수도관망에서 발생하는 누수현상은 수자원의 손실뿐만 아니라 압력손실로 인한 추가적 가압 설비의 필요성 및 누수되는 관로 주변의 토질의 약화 등을 초래하여 관망의 유지관리를 어렵게 하고, 심각한 경제적 손실을 야기하고 있다. 이에 구역고립으로 인한 수압과 유량 등을 상시 모니터링하여 누수사고의 적극적인 대처와 누수발생을 미연에 방지함으로써 유수율을 향상 시킬 수 있다 .실제 구역고립 후 계속되는 수압 조절 및 유입유량의 모니터링으로 인하여 구역내 유수율 산정결과 평균 유수율은 88.94%로서 부산광역시 2003년도의 유수율 79.5%보다 9.44% 높게 조사되었다.

  • PDF

한국형 발사체 적용 대형 박판 배관 시편 제작 및 성능 평가 (Manufacturing and Performance Evaluation on Specimen pipes with Large Size Diameter and Thin Thickness for KSLV-II)

  • 이한주;이정호;오승협
    • 항공우주기술
    • /
    • 제12권1호
    • /
    • pp.81-86
    • /
    • 2013
  • 본 연구에서는 다양한 발사체 추진기관 공급계 배관 자재 중 STS 300 계열의 금속보다 강도가 높고 용접성이 우수할 것이라고 판단되는 21-6-9 합금소재를 이용하여 산화제 주배관의 시편을 제작 하였다. 제작된 시편은 내압 시험을 수행하여 요구되는 내압 강도를 유지할 수 있는지를 확인하였다.