• Title/Summary/Keyword: Pressure-drop

Search Result 2,341, Processing Time 0.026 seconds

Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube (수평관내 이산화탄소의 증발 압력강하)

  • Ku, H.K.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

A Study on the Fluid Flow Characteristic in Catalytic Converter for Various Inlet and Outlet Header Shapes (입.출구 형상변화에 따른 촉매변환기 내의 유동특성에 관한 연구)

  • Lee, Eun-Ho;Lee, Chul-Ku;Yoo, Jai-Suk;Lee, Jong-Hwa
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.187-194
    • /
    • 1999
  • In the design of catalytic converter, velocity distribution is more important than pressure drop because monolith pressure drop is about 80% of overall pressure drop. For the catalytic converter with single diffuser, pressure drop is decreased as the angle of diffuser decrease, but when the angle is below 18$^{\circ}$, the effect is almost negligible . For the catalytic converter with double diffuser, variation of the angle of the first diffuser shows the same trend as the pressure drop while the shape of diffuser gives little influence on that The outlet shape gives negligible effect on the pressure drop and velocity . distribution . Results show that recirculation region of commercial model is aoubt 30% of the total area in the front of monolith. For the catalytic converter with Model 11 that was presented in the study, recirculation region was not detected more uniform velocity distribution was obtained, and pressure drop was also decreased.

  • PDF

Study on blockage after downward discharge of the molten metallic fuel with radiographic visualization

  • Lee, Min Ho;Jerng, Dong Wook;Bang, In Cheol
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.117-129
    • /
    • 2022
  • The downward discharge of the molten fuel to the lower structure of the fuel assembly could increase of the pressure drop and degrade of coolability of the assembly. To analyze the phenomena, experiments for the generation of the debris bed were conducted as LOF-DT series. Based on the debris bed in the LOF-DT, pressure drop experiment was conducted with intact and blocked component. Parametric study on the pressure drop was conducted by CFD. The LOF-DT experiments were conducted for the position and porosity of the debris bed. 85% of the debris were sedimented in the lower reflector, and 15% were in the nose piece, approximately. Porosity of the debris bed were about 0.7 and 0.85 in the lower reflector and nose piece, respectively. Pressure drop increased significantly with debris bed, especially in the lower reflector. More than 120 time of the pressure drop increased in the lower reflector, while only 10% increased in the nose piece. According to the parametric study, mass of the debris was the most important for pressure drop. The lower discharge phenomena could have a significant effect to the total pressure drop of the fuel assembly, approximately 10.8 times for the base case.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

Analysis of Pressure Drop for Combining Junctions in Gas-Liquid Two-Phase Flows (기액 2상 유동에서 합지관에서의 압력강하에 대한 해석)

  • 김철환;하삼철;김은필;김경천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.870-878
    • /
    • 2000
  • An experimental study and a modeling are peformed to investigate the pressure drop of combining junctions in two-phase flows. Experiments on tripod geometry used in a condenser or an evaporator, are conducted with inlet mass fluxes from 200 to$ 400 kg/m^2$s, and pipe diameters of 7 m and 9.52 m. The working fluid is R22. The result shows that the pressure drop increases as the quality does, but the effect of the increase of the pressure decreases when the diameter of a pipe increases. When the mass flux increases, the pressure drop linearly does. Furthermore, when the pipe diameter decreases, the pressure drop has a quadratic increase.

  • PDF

Study on Pressure Drop and Condensation Heat Transfer Characteristics of R-404A in Brazed Plate Heat Exchanger (R-404A를 사용한 용접형 판형 열교환기의 압력강하 및 응축 열전달특성에 관한 연구)

  • 권오갑;전창덕;강종식;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.174-183
    • /
    • 2001
  • Experimental study has been carried out on the characteristics of pressure drop and heat transfer of brazed plate heat exchangers using R-404A. Data are presented for the following range of variables: the mass flux ($20~80kg/m^2s$), chevron angle($20^{circ}C,\;35^{circ}C,\;45^{circ}C$) and inlet pressure of he refrigerant (1.4 and 1.6 MPa). for both subcooled and tow-phase flow, as chevron angle increases, pressure drop and heat transfer coefficient decrease. Condensation hat transfer coefficient and pressure drop was compared with the previously proposed correlations. Among them, Traviss correlation agreed with experimental results within -35~82% for heat transfer coefficient and -73~93% for pressure drop.

  • PDF

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

판각형 열교환기 내의 R-22 증발 압력강하 특성에 관한 실험적 연구

  • 서무교;박재홍;김영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.930-938
    • /
    • 2001
  • In this study, evaporation pressure drop experiments were conducted with two types of plate and shell heat exchangers (P&SHE) using R-22. An experimental refrigerant loop has been established to measure the evaporation pressure drop of R-22 in a vertical P&SHE. The flow channels were formed by adding three plates having a corrugated channel of a chevron angle of $45^{\circ}$. The R-22 flows down in one channel exchanging heat with the hot water flowing up in the other channel. The effect of the refrigerant mass flux, average heat flux, system pressure and vapor quality were explored in detail. During the experiment, the quality change between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.15. The present data showed that two types of P&SHE have similar trends. The pressure drop increases with the vapor quality for both types of P&SHE. At a higher mass flux, the pressure drop is higher for the entire range of the vapor quality. Also, the increase in the average heat flux increases the pressure drop. Finally, at a higher system pressure, the pressure drop is found to be slightly lower.

  • PDF

The Prediction of Injection Distances for the Minimization of the Pressure Drop by Empirical Static Model in a Pulse Air Jet Bag Filter (충격기류식 여과집진기에서 경험모델을 이용한 최소압력손실의 분사거리 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.25-34
    • /
    • 2011
  • The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (${\Delta}P_{initial}$) and the dust mass number term($N_{dust}=\frac{{\omega}_0{\nu}_f}{P_{pulse}t}$), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance ($K_d$), one of the empirical static model parameters got the minimum value at d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.

NUMERICAL ANALYSIS ON PRESSURE DROP IN EXPANDED BED ACCORDING TO TUBE-TO-PARTICLE RATIOS AND REYNOLDS NUMBERS (Expanded bed에서 레이놀즈수와 직경입자비에 따른 압력강하 특성에 관한 수치적 연구)

  • Bae, S.W.;Sung, H.G.;Roh, T.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.62-65
    • /
    • 2011
  • Characteristics of the pressure drop in an expanded bed have been compared to those in a packed bed for numerical study of the interphase drag in gas-particle flows. A numerical analysis of the pressure drop by the particle drag has been conducted according to the tube-to-particle diameter ratios and Reynolds numbers for comparison. As the tube-to-particle diameter ratios increase at the same Reynolds number, the pressure drop tends to converge. It has been confirmed that characteristics of the pressure drop in the expanded bed are similar to those in the packed bed.