• 제목/요약/키워드: Pressure-Roller

검색결과 140건 처리시간 0.025초

유연기판을 위한 UV/Thermal 하이브리드방식 나노임프린트 시스템 (UV/Thermal Hybrid Nanoimprint System for Flexible Substrates)

  • 임형준;이재종;최기봉;김기홍;안현진;류지형
    • 한국생산제조학회지
    • /
    • 제20권3호
    • /
    • pp.245-250
    • /
    • 2011
  • An UV/thermal hybrid nanoimprint lithography system was designed and implemented for the pattern transfer to flexible substrates. This system can utilize a plate stamp, roll stamp, and film stamp. For all cases of using those stamps, this system is also switchable an UV or thermal nanoimprint lithography mode. This paper shows how to design the heating and UV curing plates and proposes how to change them easily. Because the pressure condition and the speed of the press roller varies by the characteristics of the stamp and substrate, all the parameters related to the nanoimprint lithography have to adjustable. Some transferred patterns are shown in this paper to verify the performance of the hybrid nanoimprint lithography system. The flexible substrates with nano-scale patterns on them will be key components for next generation technologies such as flexible displays, bendable semi-conductors, and solar cells.

건강한 성인에게 가슴가동운동과 스트레칭운동이 최대들숨압 및 최대날숨압에 미치는 효과 (The Effects of Thoracic Mobilizing and Stretching Exercise on Maximal Inspiratory Pressure and Maximal Expiratory Pressure in Healthy Adults)

  • 김세연;황영인;김기송
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effect of chest mobilization and stretching exercises on maximal inspiratory pressure and maximal expiratory pressure in healthy adults who use computers for extended periods of time each day due to coronavirus disease 2019. Methods: Twenty-five healthy adults in their 20s and without respiratory disease (15 female, 10 male) took part in this study. Two types of thoracic mobilizing exercises using a Theraband and three types of stretching exercises using a foam roller were performed. Maximum inspiratory pressure and maximum expiratory pressure were measured three times each before and after the interventions. In terms of statistical methods, the maximum inspiratory pressure due to chest mobility and stretching was compared with the maximum expiratory pressure using parametric paired t-test and non-parametric Wilcoxon signed-rank test. Results: Maximum inspiratory pressure (p = .012) and maximum expiratory pressure (p = .006) showed significant differences before and after chest mobilization exercise and stretching among the participants. Conclusion: The results of this study suggest that chest mobilization and stretching exercises are effective exercise methods for improving maximal inspiratory and expiratory pressure. They suggest that these exercises can prevent respiratory muscle weakness and improve aerobic fitness in healthy people as well as those in need of cardiorespiratory physiotherapy.

일회용 각종 송혈관의 관류압차에 대한 비교실험 (An Experiments Analysis of Comparison of Flow Gradients Across Disposable Arterial Perfusion Cannulas)

  • 김요한;김형묵
    • Journal of Chest Surgery
    • /
    • 제19권1호
    • /
    • pp.18-24
    • /
    • 1986
  • The mean perfusion pressure produced by 20 different design and size of disposable aortic perfusion cannulas [size range: 18F to 20F] at flow rates of 1 to 5 L/min was compared. A roller pump with perfusion tubing 10mm in inner diameter was used with a mixture of 0.9% normal saline and 100% glycerin [mixing ratio of 6.72:13.28] to make the viscosity as normal blood in 20oC as the test solution. Line pressure in these cannulas at a flow rate of 3L/min ranged from 13.2$\pm$4.47 to 157$\pm$1 34 mmHg in a case of absence of resistance, and from 11.4$\pm$1.14 to 227.2$\pm$4.47 mmHg in a case of presence of resistances 14 cannulas had gradients of less than 100Hg at a flow rate of 3L/min and 9 cannulas less than 100mmHg at 4L/min. The following results were obtained from this experimental study: .1] A wide range of line pressure was observed in disposable aortic perfusion cannulas currently in clinical use; 2] Some cannulas currently used for cardiopulmonary bypass in adults generated excessive line pressure; 3] Both the material and design affect function, with some designs safer than others. Cardiac surgeons should base the choice of aortic perfusion cannula on the best performance and safest design available to avoid cannula-related problems during operation.

  • PDF

중.소형 연미기의 성능평가 및 성능개선에 관한 연구 (I)-소형연미기에 대하여 - (Performance Evaluation and Improvement of Rice Polishers of Small and Medium Size(I)-rice polisher of small size-)

  • 정종훈;최영수;권홍관
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.141-149
    • /
    • 1997
  • Structural characteristic of a rice polisher of small size was analyzed to improve its performance and to utilize such data in developing a rice polisher of large size. Spraying characteristic of nozzles which were used for rice polishing was evaluated by a machine vision system. Internal pressure of the polishing chamber was also measured according to outlet resistance, water spraying, and roller shaft speed. In addition, the performance of the polisher was analyzed based on whiteness and broken ratio according to operating conditions.

  • PDF

ECMO 시스템 적용을 위한 최적화 조건에 관한 연구 (A study on the Optimal Condition for Application with Extracorporeal Membrane Oxygenation)

  • 김재열;송민종;유신;마상동;김창현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.13-18
    • /
    • 2001
  • The ECMO system, including umbilical cord and membrane type oxygenator was connected with extracorporeal circulation unit, was applied to the fetus growth model of goat. The maximum survival time of goat fetus was 48 hours. Average blood rate for the extracorporeal circulation was $223{\pm}15.2 ml/min.$ The survival time of fetus was deeply related to body temperature, blood circulation and water temperature, anesthetized time, and fetus weights. Extern variables that are composed of anesthetized time, fetus weights, change of hemoglobin, circuit pressure, related to the survival time for fetus corrected the problem of previous ECMO model that is controlled by roller pump. It is directly delivered to heart on load. Applying the results from new ECMO model, further research will provide to the system of ECMO for human.

  • PDF

동하중에 의한 강성벽체에 작용하는 토압 (Earth Pressure Acting on Rigid Retaining Wall due to the Dynamic Load)

  • 박종덕;전용백
    • 한국지반공학회논문집
    • /
    • 제16권5호
    • /
    • pp.157-168
    • /
    • 2000
  • 토류구조물의 안정문제로는 장단기적으로 정적인 경우와 동적인 경우, 그리고 지반의 동적 거동특성, 흙의 강도저하 등을 미리 파악하여 기술적인 대처를 할 필요가 있을 것이다. 본 연구에서는 실내 모형 실험을 통하여 구조물의 배면에 토성이 다른 일반모래, 표준모래, 점성토를 뒷채움하여 다짐없이 강사만 하고, 룰러다짐, 진동다짐을 하여 토피의 수평 진동거리를 길게, 짧게 그리고 중간으로 하여 강성벽체에 작요?는 수평토압에 대한 정적, 동적 특성을 규명하는 것이다. 모형 실험장치로는 실험대, 토조, 토압측정장치, 진동하중 발생장치, 진동측정장치, 강사기, 롤러 등을 설치하여 거리에 따른 병진운동으로 가속도와 수평토압, 수평토압계수, 전체토압, 토압의 작용점, 지진토압증분 증을 구하여, 실험결과와 기존 이론결과, 그리고 유한요소 해석결과와 비교 고찰하였다.

  • PDF

표면 Rolling시 가압력이 표면 조도에 미치는 영향 (An effect of load on surface roughness in surface rolling)

  • 강명순
    • 오토저널
    • /
    • 제9권5호
    • /
    • pp.57-65
    • /
    • 1987
  • The surface rolling method which is one of the plastic deformation processes increases the surface roughness with reduction of diameter and hardness. In this study, three NACHI 6000 ZZ bearing were used for surface rolling tool on a mild steel The following results have been obtained with the mild steel. 1) The load is major factor in getting fine surface roughness of roller finishing after grinding The optimal surface roughness of SS41 steel can be obtained at the contact pressure of 210 kgf/cm$^{2}$. 2) At the contact pressure range of 200kgf/cm$^{2}$-210kgf/cm$^{2}$ for optimal surface roughness, The surface hardness increased to Hv200-Hv240 from Hv 125 before surface rolling. 3) Within the diameter variation of 13 .mu.m the surface roughness and the surface hardness were increased, but out of variation of 14.mu.m. The surface roughness become worse and the surface hardness was increased.

  • PDF

박동류 및 비박동류에 의한 체외순환의 비교 (Comparative Studies of Pulsatile and Nonpulsatile Blood Flow during Cardiopulmonary Bypass)

  • 선경;백광제;김요한;임창영;김광택;김학제;김형묵
    • Journal of Chest Surgery
    • /
    • 제18권2호
    • /
    • pp.182-192
    • /
    • 1985
  • [here are so many reports that pulsatile blood flow provides physiologic organ perfusions during cardiopulmonary bypass. So, we compared the recent 30 cases undergoing cardiac surgery by Cobe-Stckert pulsatile roller pump with another 30 cases by Polystan nonpulsatile roller pump. Pulsatile flow was applied during aortic-cross clamping period when synchronized to internal EKG simulator, and perfusion mode was changed to continuous nonpulsatile flow after declamping of aorta. Age, sex, weight, and disease entities were comparable and operative techniques were similar between two groups. 1. There were no differences in average ACC time, ECC time, and Operation time. 2. Postoperative artificial respiration time was 6hrs 30mins in nonpulsatile group and 4hrs 48mins in pulsatile group, and detubation time after ventilator weaning was 2hrs 44mins in nonpulsatile group and 1hrs 43mins in pulsatile group. 3. Average pulse pressure was 8mmHg in nonpulsatile group and 55mmHg in pulsatile group, and a mean arterial pressure was 66.0mmHg in nonpulsatile group and 60.7mmHg in pulsatile group. 4. Mean urine-output during ACC;ECC period was 9.717.3;9.913.2ml/kg/hr in nonpulsatile group and 14.215.0;15.817.5 in pulsatile group [p<0, 05], and thereafter progressive decrease of differences in urine output between two groups until POD 2, and lesser amounts of diuretics was needed in pulsatile group during same postoperative period. Serum BUN/Cr level showed no specific difference and urine concentration power was well preserved in both groups. 5. Plasma proteins and other Enzymes showed no differences between two groups, but serum GOT/GPT level was higher in nonpulsatile group till POD 2. 6. Serum Electrolytes showed no differences between two groups. 7. WBC, RBC, Platelet counts, Hgb and Hct were not different and Coagulogram was well preserved in both groups. 8. Plasma free Hgb level was 7.09mg% in pulsatile group compared with 3.48mg% in pulsatile group on POD 1 but was normalized on POD 2. Gross hemoglobinuria after ECC was noted in 6 cases [20%] of pulsatile group and 4 cases [13%] of nonpulsatile group. 9. In both groups, most patients were included in NYHA class III to IV [28 cases;93% in nonpulsatile group, 22 cases;73% in pulsatile group] preoperatively, and well improved to class I to 11[22 cases; 73% in nonpulsatile group, 30 cases; 100% in pulsatile group] postoperatively. There were 7 operative mortalities in nonpulsatile group only, which were 5 cases of TOF with hepatic failure, 1 case of multiple VSDs with low out-put syndrome, and 1 case of mitral valvular heart disease with cardiomyopathy. We concluded that the new, commercially available Cobe-Stckert pulsatile roller pump device was safe, simple, and reliable.

  • PDF

다양한 도구의 적용이 뒤넙다리근의 뻣뻣함과 근 긴장도에 미치는 영향 (The Effect of Applying Various Tools to the Stiffness and Muscle Tone of Hamstring Muscles)

  • 황성현;김태호
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.223-230
    • /
    • 2020
  • Purpose : The purpose of this study was to examine the effects of tools (i., extracorporeal shock wave therapy, massage gun, and foam roller) on range of motion, muscle tone and pain threshold among patients with hamstring stiffness. Methods : Fourteen participants with hamstrings stiffness were recruited. Interventions were performed 6 times, and each session was for 30 seconds using the three tools. The range of motion, muscle tone, and pain threshold were measured. The order of the use of the three tools was randomly determined. The foam roller was made to move from the bottom of the hip crease to the upper part of the back of the hamstring. Additionally, velocity 5 vibration stimulation was performed on the hamstring using a massage gun. Moreover, vibration stimulation was performed on the hamstring with extracorporeal shock wave therapy 5 minutes, 5 Hz, and 1,500 strokes. The flexibility of the posterior thigh muscle was based on maintaining the knee and hip joints in a 90 ° bend in the supine position. The joint angle of the knee was measured, when the knee was actively extended, at the maximum point where the posterior thigh muscle was stretched. The elasticity of the posterior thigh muscle was measured while the subject was prone and in a relaxed state without any force. Measurements were made at the muscle abdominal area of the semitendinosus muscle of the posterior femur, and the area to be measured was marked with a pen. The measurement of the tenderness threshold of the posterior femur was measured using a tenderness meter(Commander Algometer, J-Tech, USA). The force value at the point at which the pressure sensation change to pain was measured after applying vertical pressure to the posterior femur muscle, which was the halfway point between the ischial tuberosity and the popliteal surface of the subject lying on their stomach. Results : The extracorporeal shock wave therapy increased stiffness and, muscle tone, and caused changes in the pain threshold, whereas the other two tools had no effect on these indices. Conclusion : Extracorporeal shock wave therapy has important effects on range of motion and muscle stiffness and can be used in warmup protocols.

이축압축 조건에서 실험체/재하판 경계면상의 마찰저항 감소를 위한 롤러 지지된 피스톤 형태의 하중재하판의 개발 (Development of a roller supported piston type loading platen reducing the frictional restraint along the interfaces between the specimen and platens under the biaxial loading condition)

  • 사공명;김세철;이준석;박두희
    • 한국터널지하공간학회 논문집
    • /
    • 제10권3호
    • /
    • pp.303-312
    • /
    • 2008
  • 암석의 물성평가 및 파괴모델 실험을 위하여 다축압축 실험이 자주 사용된다. 다축압축 실험을 통한 암반의 거동 평가시 정확한 결과의 산출을 위하여 실험체와 가압판 경계면에서의 경계조건에 대한주의를 기울일 필요가 있다. 일반적으로 철제로 된 일체형 가압판의 사용시 실험체의 경계면과 하중재하판사이에서 발생하는 마찰저항으로 인하여 실험체 경계부에서부터 응력회전 현상이 발생하여 경계면에서부터 작용하는 외력의 방향은 회전하게 된다. 이와 같은 실험체/하중재하판 경계면 사이에서 발생하는 마찰저항을 감소시키기 위하여 다양한 방법이 제시되었다. 그 중 대표적인 예가 빗살구조의 하중재하판이다. 본 논문에서는 빗살구조의 하중재하판의 단점을 극복하고 하중재하판의 공간이 상대적으로 덜 차지하는 롤러로 지지된 피스톤 형태의 하중재하판을 소개하고 있다. 롤러로 지지된 피스톤 형태의 하중재하판은 지지강성이 충분한 짧은 피스톤 후면에 샤프트 형태의 롤러를 설치하여 실험체의 변형과 동시에 각 피스톤이 동반하여 거동하도록 구성되었다. 본 논문에서는 롤러 지지된 피스톤의 구조 상세 및 요구되는 기능에 대한 검증을 위하여 측면부 마찰저항 실험과 이축압축 실험이 수행되었으며 실험결과와 수치해석 결과의 비교를 통하여 장비의 적용성에 대한 검증이 이루어 졌다.

  • PDF