• Title/Summary/Keyword: Pressure waveform

Search Result 160, Processing Time 0.025 seconds

Waveform characterization and energy dissipation of stress wave in sandstone based on modified SHPB tests

  • Cheng, Yun;Song, Zhanping;Jin, Jiefang;Wang, Tong;Yang, Tengtian
    • Geomechanics and Engineering
    • /
    • v.22 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • The changeable stress environment directly affect the propagation law of a stress wave. Stress wave propagation tests in sandstone with different axial stresses were carried using a modified split Hopkinson Pressure bar (SHPB) assuming the sandstone has a uniform pore distribution. Then the waveform and stress wave energy dissipation were analyzed. The results show that the stress wave exhibits the double peak phenomenon. With increasing axial stress, the intensity difference decreases exponentially and experiences first a dramatic decrease and then gentle development. The demarcation stress is σ/σc=30%, indicating that the closer to the incident end, the faster the intensity difference attenuates. Under the same axial stress, the intensity difference decreases linearly with propagation distance and its attenuation intensity factor displays a quadratic function with axial stress. With increasing propagation distance, the time difference decays linearly and its delay coefficient reflects the damage degree. The stress wave energy attenuates exponentially with propagation distance, and the relations between attenuation rate, attenuation coefficient and axial stress can be represented by the quadratic function.

ACOUSTIC EMISSION CHARACTERISTICS OF STRESS CORROSION CRACKS IN A TYPE 304 STAINLESS STEEL TUBE

  • HWANG, WOONGGI;BAE, SEUNGGI;KIM, JAESEONG;KANG, SUNGSIK;KWAG, NOGWON;LEE, BOYOUNG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.454-460
    • /
    • 2015
  • Acoustic emission (AE) is one of the promising methods for detecting the formation of stress corrosion cracks (SCCs) in laboratory tests. This method has the advantage of online inspection. Some studies have been conducted to investigate the characteristics of AE parameters during SCC propagation. However, it is difficult to classify the distinct features of SCC behavior. Because the previous studies were performed on slow strain rate test or compact tension specimens, it is difficult to make certain correlations between AE signals and actual SCC behavior in real tube-type specimens. In this study, the specimen was a AISI 304 stainless steel tube widely applied in the nuclear industry, and an accelerated test was conducted at high temperature and pressure with a corrosive environmental condition. The study result indicated that intense AE signals were mainly detected in the elastic deformation region, and a good correlation was observed between AE activity and crack growth. By contrast, the behavior of accumulated counts was divided into four regions. According to the waveform analysis, a specific waveform pattern was observed during SCC development. It is suggested that AE can be used to detect and monitor SCC initiation and propagation in actual tubes.

Duplex Sonography in Subclavian Steal Syndrome Treated by Stent Insertion (이중초음파검사상 빗장밑혈류빼앗김증후군이 관찰된 환자에서의 스텐트 삽입 후 추적)

  • Han, Minho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.370-374
    • /
    • 2018
  • Subclavian steal syndrome is a type of obstructive artery disease caused by severe stenosis and occlusion of a left proximal subclavian artery or brachiocephalic trunk. The resulting vertebro-basilar insufficiency symptoms are due to retrograde blood flow from the contralateral vertebral and basilar arteries into the low-pressure ipsilateral upper extremity vessels. For that reason, patients usually experience dizziness or arm ischemic symptoms. Neurointervention is an effective treatment for ischemic stroke, including the subclavian artery stenosis. This paper reports a patient with subclavian steal syndrome who had a vertebral artery Doppler waveform change in duplex sonography and a 12 mmHg difference in interarm systolic blood pressure. A stenotic lesion of the subclavian artery was treated effectively by inserting a precise stent. The follow up examination showed that the vertebral artery Doppler waveform change disappeared and recovered and that the 12 mmHg difference in interarm systolic blood pressure decreased to 5 mmHg after treatment.

The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Bui, Ngoc-Hung;Jung, Hyun-Seok;Lee, Wook-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.10
    • /
    • pp.1533-1542
    • /
    • 2003
  • In the present study, the characteristics of pressure oscillation and heat transfer performance in an oscillating capillary tube heat pipe were experimentally investigated with respect to the heat flux, the charging ratio of working fluid, and the inclination angle to the horizontal orientation. The experimental results showed that the frequency of pressure oscillation was between 0.1 Hz and 1.5 Hz at the charging ratio of 40 vol.%. The saturation pressure of working fluid in the oscillating capillary tube heat pipe increased as the heat flux was increased. Also, as the charging ratio of working fluid was increased, the amplitude of pressure oscillation increased. When the pressure waves were symmetric sinusoidal waves at the charging ratios of 40 vol.% and 60 vol.%, the heat transfer performance was improved. At the charging ratios of 20 vol.% and 80 vol.%, the waveforms of pressure oscillation were more complicated, and the heat transfer performance reduced. At the charging ratio of 40. vol.%, the heat transfer performance of the OCHP was at the best when the inclination angle was 90$^{\circ}$ the pressure wave was a sinusoidal waveform, the pressure difference was at the least, the oscillation amplitude was at the least, and the frequency of pressure oscillation was the highest.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Novel Detection Algorithm of The Upstroke of Pulse Waveform for Continuously Varying Contact Pressure Method (연속 가압방식의 맥파 측정방법을 위한 시작점 검출 알고리즘 개발)

  • Bae, Jang-Han;Jeon, Young-Ju;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.46-54
    • /
    • 2012
  • We propose a continuously varying contact pressure(CVCP)-adaptive feature extraction algorithm for pulse diagnostic analysis. The CVCP method measures the pulse waveform with continuously increasing contact pressure(CP). This method offer a high resolution signal of the pulse waveform amplitude(PWA) as a function of the contact pressure. Therefore it enables us to overcome the limitation of commercially available pulse-taking devices whose analysis rely on a few number of PWA-CP pairs. We show that an efficient feature extraction algorithm which covers the features of the CVCP-method can be developed by sequentially applying Fast Fourier Transform, peak detection by center-to-edges method, baseline drift removal, detection of the percussion wave upstroke by intersecting tangent method and detection of the analysis region. Finally, by a clinical study with 30 subjects, we show that our CVCP-adaptive feature extraction algorithm detected the upstroke with accuracy of 99.46% and sensitivity of 99.51%, which were about 4.82% and 2.46% increases respectively, compared to a conventional feature extraction method. The proposed CVCP method and the CVCP-adaptive feature extraction algorithm are expected to improve the accuracy in the pulse diagnostic algorithms such as floating/sunken pulse qualities and deficient/excess pulse qualities.

A Study on the Comparision of Electron Energy Distribution Function measured by sawtooth and triangle waveform probe bias voltages (톱니파 및 삼각파 프로브 bias 전압에 의해 측정된 전자에너지 분포함수의 비교에 관한 연구)

  • Kim, D.H.;Shin, J.H.;Kim, G.S.;Park, Y.C.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1844-1847
    • /
    • 1996
  • In the paper, we have obtained electron energy distribution function (EEDF) in plasma by using two differentiators. In addition, we have investigated the comparision of the EEDFs by sawtooth and triangle waveform voltages. It is found that as pressure is decreased, electron density is decreased, and plasma potential is increased. And as the position of probe moves the outer of plasma, plasma potential is decreased, and electron temperature is decreased.

  • PDF

Correlation of Axillary Artery Pressure and Phase of Esophageal Impedance in Chickens

  • Nakajima, Isao;Kuwahira, Ichiro;Hori, Shuho;Mitsuhashi, Kokuryo
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Under General anesthesia with isoflurane, we insert a chicken's esophageal catheter into the near the left atrium. 1MHz radio wave was added to electrocardiogram electrodes of the esophagus, and the change of impedance (phase) was obtained by amplitude synchronous detection technique. At the same time, a thin tube is surgically inserted into the axillary artery to continuously measure blood pressure. The correlation between impedance (phase) and blood pressure was obtained. Both showed a very high correlation (R2=0.9665). It was also observed the waveform flowing from the left atrium into the left ventricle. When an individual infected with the avian influenza virus develops, the cytokine storms lead to hypotension earlier than the test for antigen-antibody reaction. In order to detect this, in the future, this impedance technique will be useful for screening individuals infected with avian influenza virus by measuring the blood pressure of chickens in cages in a non-contact manner using microwaves.

The Analysis of Light Emissions on Ar DC Glow Discharge under the Atmosphere Pressure (대기압 Ar 직류 글로우 방전에서 인가전압의 파형특성에 따른 광원효율 분석)

  • SO, Soon-Youl
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.865-872
    • /
    • 2019
  • We developed a one-dimensional Ar fluid model running in DC-type applied voltage with a sine and a pulse waveform at the atmosphere pressure. We investigated the light emissions and efficiencies of ${\lambda}_{128nm}$, ${\lambda}_{727nm}$, ${\lambda}_{912nm}$ and ${\lambda}_{966nm}$ from the Ar excited particles. From the results, the light emission of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ in the applied voltage with a sine waveform were almost two times as in DC voltage type. The shorter the switching time of applied voltage was, the more the light emissions of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ were. We discussed the power consumption and Joule heating by charged particles.

Estimation of Target and Completion Pressure during the Cuff Inflation Phase in Blood Pressure Measurement (혈압측정시 가압 단계에서 목표압력 및 측정 종료압력 추정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Kim, Young-Soo;Shen, Dong-Fan;Kim, In-Young;Chee, Young-Joan
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.371-375
    • /
    • 2008
  • In blood pressure measurement, the oscillometric method detects and analyzes the pulse pressure oscillation while deflating the cuff around the arm. For its principle, one has to inflate cuff pressure above the subject's systolic pressure and deflate below the diastolic pressure. Most of the commercialized devices inflate until the fixed target pressure and deflate until the fixed completion pressure because there is no way to know the systolic and diastolic pressure before measurement. Too high target pressure makes stress to the subject and too low target pressure makes big error or long measurement time because of re-inflation. There are similar problems for inadequate completion pressure. In this study, we suggest new algorithm to set proper target and completion pressure for each subject by analyzing pressure waveform while inflating period. We compared our proposed method and auscultation method to see the errors of estimation. The differences between the two measurements were -4.02$\pm$4.80mmHg, -10.50$\pm$10.57mmHg and -0.78$\pm$5.l7mmHg for mean arterial pressure, systolic pressure and diastolic pressure respectively. Consequently, we could set the target pressure by 30 mmHg higher than our estimation and we could stop at 20mmHg lower than our estimated diastolic pressure. Using this method, we could reduce the measurement time.