• 제목/요약/키워드: Pressure transducer

검색결과 329건 처리시간 0.028초

스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석 (Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification)

  • 안상규;김승종;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

VERIFICATION OF COSMOS CODE USING IN-PILE DATA OF RE-INSTRUMENTED MOX FUELS

  • Lee, Byung-Ho;Koo, Yang-Hyun;Cheon, Jin-Sik;Oh, Je-Yong;Joo, Hyung-Kook;Sohn, Dong-Seong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2002년도 춘계공동학술발표회요약집
    • /
    • pp.242-242
    • /
    • 2002
  • Two MIMAS MaX fuel rods base-irradiated in a commercial PWR have been reinstrumented and irradiated at a test reactor. The fabrication data for two MOX roda are characterized together with base irradiation information. Both Rods were reinstrumented to be fitted with thermocouple to measure centerline temperature of fuel. One rod was equipped with pressure transducer for rod internal pressure whereas the other with cladding elongation detector. The post irradiation examinations for various items were performed to determine fuel and cladding in-pile behavior after base irradiation. By using well characterized fabrication and re-instrumentation data and power history, the fuel performance code, COSMOS, is verified with measured in-pile and PIE information. The COMaS code shows good agreement for the cladding oxidation and creep, and fission gas release when compared with PIE dad a after base irradiaton. Based on the re-instrumention information and power history measured in-pile, the COSMOS predicts re-instrumented in-pile thermal behaviour during power up-ramp and steady operation with acceptable accuracy. The rod internal pressure is also well simulated by COSMOS code. Therfore, with all the other verification by COSMOS code up to now, it can be concluded that COSMOS fuel performance code is applicable for the design and license for MaX fuel rods up to high burnup.

  • PDF

적혈구 변형성의 측정과 혈액 점도와의 상관관계 연구 (Measurements of RBC deformability and its effect on blood viscosity)

  • 구윤희;박명수;신세현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1682-1686
    • /
    • 2004
  • A slit-flow apparatus with laser diffraction method has been developed with significant advances in ektacytometry design, operation and data analysis. In the slit-flow ektacytometry (or laser-diffractometry), the deformation of red blood cells subjected to continuously decreasing shear stress in slit flow is measured. A laser beam traverses a diluted blood suspension flowing through a slit and is diffracted by RBCs in the volume. The diffraction patterns are captured by a CCD-video camera, linked to a frame grabber integrated with a computer, while the differential pressure variation is measured by a pressure transducer. Both measurements of laser-diffraction image and pressure with respect to time enable to determine deformation index and the shear stress. The range of shear stress of 0 ${\sim}$ 35 Pa and measuring time is less than 2 min. When deforming under decreasing shear stress, RBCs change gradually from the prolate ellipsoid towards a circular biconcave morphology. The Deformation Index (DI) as a measure of RBC deformability is determined from an isointensity curve in the diffraction pattern using an ellipse-fitting program. The advantages of this design are simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

Water / R22 폭발실험수행을 통한 증기폭발에 관한 연구 (Experimental Investigation on the Vapor Explosions with Water/R22)

  • Park, I.K.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 1994
  • 원자력발전소 중대사고시 용융된 노심과 잔류냉각수가 증기폭발을 일으켜 원자로 격납용기의 건전성을 위협할 수 있다. 본 연구에서는 증기폭발을 모사할 수 있는 실험 장치를 제작하고, 물과 프레온을 사용하여 증기폭발실험을 수행하였다. 이때 고속카메라를 사용하여 폭발현상을 관측하였고, 동압측정기와 압력분출관을 이용하여 생성되는 폭발압력과 기계적인 에너지를 계측하였다. 이를 토대로 증기폭발의 중요인자들(물의 온도, 물의 주입속도, 물의 주입 시간, 그리고 냉매의 깊이)에 대한 민감도 분석을 수행하였다. 그리고, 압력용기 바닥의 구조물이 용융/냉각재의 반응에 미치는 영향을 살펴보기위하여 실험용기 내부에 그리드를 설치하여 폭발실험을 실시하였다. 물/프레온의 폭발실험에서 계측된 기계적에너지를 이용한 에너지효율은 0.5∼l.6%인 것으로 계산되었다.

  • PDF

반원 리브의 거칠기를 가진 사각덕트에서의 난류 및 마찰 특성에 관한 실험적 연구 (Experimental Study on Turbulence and Pressure Drop Characteristics in a Rectangular Duct Fitted with Semicircular Ribs)

  • 모하마드 줄커나인;이경환;우주식;정한식;정효민
    • 동력기계공학회지
    • /
    • 제15권5호
    • /
    • pp.43-48
    • /
    • 2011
  • The article represents an experimental investigation on friction and turbulent flow characteristics of free airflow through a rectangular duct fitted with semicircular ribs of uniform height (e = 3.5 mm) on one principle wall. The aspect ratio of the rectangular duct was AR= 5 where the duct height (H) was of 30 mm. Four different rib pitches (P) of 28 mm, 35 mm, 42 mm and 49 mm were used for constant rib height to hydraulic diameter ratio (e/Dh = 0.07) and constant rib height to channel height ratio (e/H = 0.11). The experimental results show some significant effects on pressure drop as well as turbulent characteristics at various configurations among different numbers of rib arrangements varying Reynolds number in the range of 15000 to 30000. Pressure transducer and hot wire anemometer were used for data acquisition of this experiment.

성인용 공기구동식 심실보조장치의 모의순환실험 (In Vitro Test of an Adult-Sized Pneumatic Type Ventricular Assist Device)

  • 김상현;장병철;김원기;김남현;조범구
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권2호
    • /
    • pp.163-167
    • /
    • 1993
  • We developed a ventricular assist device(VAD) to be used as a bridge to heart transplantation or a circulatory assist device for patients with end-stage heart disease or poor myocardial function after cardiac surgery. It is a pneumatic and diaphragm-type VAD and its stroke volume is 90 cc. The upper housing and diaphragm is made of a segmented polyurethane and the lower back plate is made of a polycarbonate. Two Carbomedics$^R$ mechanical valves are used as inlet and outlet valves. It was tested in vitro and the cardiac output of the VAD was 7 L/min at a heart rate of 70 bpm. The line pressure from a pressure transducer inserted in the pneumatic line was recorded and compared with the ideal pressure tracing.

  • PDF

삼음교(三陰交) 침자(鍼刺)가 부교감신경(副交感神經)의 방광분지(膀胱分枝), 경골신경(脛骨神經) 및 혈압(血壓)에 미치는 영향(影響) (Neurologic Study of SP6(Sanyinjiao, 三陰交) Acupuncture on Bladder parasympathetic Nerve, Tibial Nerve and Blood Pressure in Rats)

  • 박춘하;윤여충;나창수
    • Journal of Acupuncture Research
    • /
    • 제19권1호
    • /
    • pp.175-188
    • /
    • 2002
  • Objective : The effects of SP6(Sanyinjiao, 三陰交) acupuncture stimulation on bladder parasympathetic nerve activity (PNA), tibial nerve activity (TNA) as well as blood pressure were examined in anesthetized rats and the results are as follows. Methods : The parasympathetic nerve leading to the bladder was exposed retroperitoneally, and the tibial nerve in the hindlimb was exposed through inguinal area. PNA and TNA were recorded using a bipolar platinum-iridium wire electrode and it was connected to preamplifier. Blood pressure was measured using cannula that was inserted into femoral artery and was recorded with blood pressure sensor that is connected with transducer amplifier. The mean value of all parameters measured for 30 seconds before the stimulation was expressed as 100%. An acupuncture needle was inserted into the SP6 region to a depth of 4 mm. Results : Under intact state (IS), acupuncture stimulation for 120 seconds induced significant increase of PNA which was accompanied with decrease of blood pressure. At the same time, TNA showed temporary increase only with acupuncture stimulation. In 4 mg/kg of naloxone-administrated state (NAS), significant decrease of PNA was seen and it was accompanied with increase of blood pressure. TNA also showed temporary increase only with acupuncture stimulation under the NAS just like the IS. Conclusion : consider that SP6(Sanyinjiao, 三陰交) acupuncture stimulation activated parasympathetic nerve and caused vasodilation to lead into the diuresis, but naloxone reversed the effect of acupuncture for antidiuresis.

  • PDF

1-G 진동대 실험을 이용한 시트파일 보강재의 액상화 및 피해 방지 효과 (Liquefaction Prevention and Damage Reduction Effect of Reinforcement by Sheet Pile Using 1-G Shaking Table Test)

  • 심성훈;윤종찬;손수원;김진만
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.211-217
    • /
    • 2020
  • Earthquake preparedness has become more important with recent increase in the number of earthquakes in Korea, but many existing structures are not prepared for earthquakes. There are various types of liquefaction prevention method that can be applied, such as compaction, replacement, dewatering, and inhibition of shear strain. However, most of the liquefaction prevention methods are applied before construction, and it is important to find optimal methods that can be applied to existing structures and that have few effects on the environment, such as noise, vibration, and changes in underground water level. The purpose of this study is to estimate the correlation between the displacement of a structure and variations of pore water pressure on the ground in accordance with the depth of the sheet file when liquidation occurs. To achieve this, a shaking table test was performed for Joo-Mun-Jin standard sand and an earth pressure, accelerometer, pore water pressure transducer, and LVDT were installed in both the non-liquefiable layer and the liquefiable layer to measure the subsidence and excess pore water pressure in accordance with the time of each embedded depth. Then the results were analyzed. A comparison of the pore water pressure in accordance with Hsp/Hsl was shown to prevent lateral water flow at 1, 0.85 and confirmed that the pore water pressure increased. In addition, the relationship between Hsp/Hsl and subsidence was expressed as a trend line to calculate the expected settlement rate formula for the embedded depth ratio.

Characterization of flow properties of pharmaceutical pellets in draft tube conical spout-fluid beds

  • Foroughi-Dahr, Mohammad;Sotudeh-Gharebagh, Rahmat;Mostoufi, Navid
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.274-281
    • /
    • 2018
  • Experimental studies of the hydrodynamic performance of the draft tube conical spout-fluid bed (DCSF) were conducted using pharmaceutical pellets. The experiments were carried out in a DCSF consisted of two sections: (a) a conical section with the cross section of $120mm{\times}250mm$ and the height of 270 mm, (b) a cylindrical section with the diameter of 250 mm and the height of 600 mm. The flow characteristics of solids were investigated with a high speed camera and a pezoresistive absolute pressure transducer simultaneously. These characteristics revealed different flow regimes in the DCSF: packed bed at low gas velocities, fluidized bed in draft tube at higher gas velocities until minimum spouting, and spouted bed. The stable spouting was identified by the presence of two dominant frequencies of the power spectrum density of pressure fluctuation signature: (i) the frequency band 6-9 Hz and (ii) the frequency band 12-15 Hz. The pressure drops across the draft tube as well as the annulus measured in order to better recognize the flow structure in the DCSF. It was observed that the pressure drop across the draft tube, the pressure drop across the annulus, and the minimum spouting velocity increase with the increase in the height of draft tube and distance of the entrainment zone, but with the decrease in the distributor hole pitch. Finally, this study provided novel insight into the hydrodynamic of DCSF, particularly minimum spouting and stable spouting in the DCSF which contains valuable information for process design and scale-up of spouted bed equipment.

자궁암 치료용 다채널 초음파 온열치료기 (Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix)

  • 이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.16-23
    • /
    • 2005
  • 본 연구에서는 자궁경부암 및 질암 치료 시 고선량률 강내 근접치료기와 병행하여 사용가능한 다채널 초음파 온열 치료 기구를 제작하였다. 텐덤형의 경우 자궁 내에 삽입이 용이하도록 외부직경 4 mm, 두께 0.7 mm, 길이 24.5 mm인 원통형 plezo-ceramic crystal transducer (PZT-5A) 물질이 초음파 발생원으로 사용되었다. 질벽 또는 질 천정치료에 이용될 치료기는 질에 삽입되어야 하므로 질의 크기와 비슷한 직경 24.5 mm, 두께 1.3 mm, 길이 15.2 mm인 원통형 PZT-8 물질이 이용되었다. 임피던스와 phase 측정결과에 따라 외부직경이 4 mm인 PZT-5A의 작동주파수는 3.2 MHz 로 결정되었고 외부직경이 24.5 mm인 PZT-8 물질의 작동 주파수는 1.7 MHz로 결정되었다. Radiation force 방법으로 측정된 초음파 발생효율은 텐덤형 초음파원은 33%이고 원통형 초음파원은 61%이다. 원통형 초음파 발생물질로부터 발생되는 초음파 분포도를 MATLAB을 이용하여 계산하였고 실제 물 팬텀 내에서 열전대를 이용하여 측정하였다. 계산을 통해 얻어진 radial 한 방향으로 방사된 초음파압은 자궁내로 삽입되는 텐덤형 트랜스듀서의 경우 표면에서 5 mm 되는 점을 기준으로 10 mm 에서는 58%이고 20 mm에서는 45%이다. 질 치료에 사용될 트랜스듀서의 세기는 표면으로부터 5 mm에서의 세기를 기준으로 15 mm 거리에서는 78%, 25 mm 거리에서는 66%로 감소하였다. 특성분석 결과 직경 4 mm인 PZT-5A 와 24.5 mm인 PZT8 물질은 온열치료의 초음파원으로 사용가능함이 입증되었다. 따라서 직경 4 mm인 PZT-5A 트랜스듀서 3개를 연결하여 치료길이가 75 mm인 텐덤형 온열치료기구를 제작하였고 직경 24.5 mm인 PZT-8 트랜스듀서 4개를 연결하여 치료길이가 61 mm인 질암 치료용 온열치료기구를 제작하였다.

  • PDF