• 제목/요약/키워드: Pressure sensitivity level

Search Result 122, Processing Time 0.031 seconds

Effects of Lifestyles, Dietary Habits, Food Preferences and Nutrient Intakes on Sensitivity to and Preference for Salty Tastes of Korean Women

  • Lee, Hong-Mie
    • Journal of Community Nutrition
    • /
    • v.8 no.4
    • /
    • pp.185-192
    • /
    • 2006
  • This study was performed to investigate factors affecting sensitivity and preference for salty tastes of Korean adult females. Sensitivity and preference for salty tastes were determined as detection threshold concentration of NaCl solution and the optimally-preferred NaCl concentration of the bean sprout soup, respectively. A self-administered questionnaire was used to obtain the information regarding general characteristics, self diagnosis of stress, health-related lifestyle practices, dietary habits and food preferences. Dietary intake using 24-hours recall and blood pressure were measured. Salty taste detection thresholds and optimally-preferred NaCl concentrations were 0.0197% and 0.357%, respectively. There was a significant positive correlation between the optimally-preferred salt concentration and age, despite no significant correlation between either sensitivity or preference for salty taste and sodium intake, which was 3,605mg/day. Those who had bread or cereal with milk as breakfast instead of a traditional Korean meal and those who preferred jjigae to soup had significantly higher NaCl preferences for bean sprout soup. Going to bed after midnight and skipping meals (${\geq}3/week$) decreased salty taste sensitivity without reaching statistical significance. Self awareness of one's own health, recent weight changes, family history of hypertension, sleep quality, getting-up time, rate of eating and other food preferences did not affect either perception. Stress level, TV watching, BMI and sodium intake did not have significant correlation to sensitivity or preference. Further research including a large number of well-controlled subjects and more accurate measurement of sodium intake should be directed to find other factors affecting salt preference and sensitivity in order to decrease Na intake and related diseases.

Relationship between urinary na, Ca Excretion and Hormonal Factors in Hypertensive and Normotensive Patients (고혈압과 정상혈압 환자에 있어서 Na, Ca 배설 및 관련 요인에 관한 연구)

  • 윤진숙
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.5 no.1
    • /
    • pp.67-74
    • /
    • 1995
  • The aim of this study was to investigate the interrelationship among urinary excretion dietary habit of Na, Ca intake and hormonal factors in 22 hypertensive and 30 normotensive hospitalized patients. The results were summarized as follows : 1. Urinary excretion of Na in normotensive patients was not significantly different from that of hypertensive patients, while Ca excretion(as expressed on the basis of mg of creatinine) was significantly higher in hypertensive patients. 2. Habitual dietary intake of Na, Ca in hypertensive patients were not significantly different from those of normotensive patients. 3. There were no significant differences in mean plasma renin activity, aldosterone and parathyroid hormone(PTH) level between two groups. However, systolic pressure significantly correlated with PTH(r=0.2597) and aldosterone level(r=0.24648)(P<0.05). In this study blood pressure did not show any significant relationship between urinary Na excretion and habitual dietary Na intake of Na. It is speculated that individual difference of Na sensitivity might result in heterogenous blood pressure response to dietary Na intake. Higher Ca excretion in hypertensive subjects suggested a future study on the interrelationship between Ca metabolism and aldosterone system in hypertension.

  • PDF

Prevention of Pressure Ulcer using the Pressure Ulcer Risk Assessment Based on Braden Scale (Braden Scale에 기초한 욕창발생 위험군 선별도구를 이용한 욕창의 예방)

  • Oh, Deuk Young;Kim, Jee Hoon;Lee, Paik Kwon;Ahn, Sang Tae;Rhie, Jong Won
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.466-470
    • /
    • 2007
  • Purpose: Active prevention is an essential component in reducing the development of pressure sores. For the high-risk patient group, following the certified pressure sore screening scale as well as educating the patient and the nurses who care for them can lead to optimal management of these patients. Applying a risk assessment scale along with a prevention strategy can reduce medical costs and length of stays at the hospital. The purpose of this study is to evaluate the efficacy of a new pressure sore risk assessment scale based on the universally recommended Braden scale and our prevention program. Methods: From June to August, 2003, our pressure ulcer risk assessment scale was applied to a total of 1882 patients admitted to the experimental group (intensive care unit, neurosurgery, general surgery, and oncology units). It was based on Braden scale. We analysed sensitivity, specificity, positive and negative predictive value and ROC curve to evaluate its efficacy. Pressure ulcer prevention program was composed of patient's education using protocol and specific nursing care. The incidence of pressure ulcers was also measured during the 3 months period, and those were compared to the control group of 1789 patients from March to May, 2002. Results: 118(6.27%) of the experimental group were high-risk with an incidence of pressure ulcers measuring 4 (0.21%). Sensitivity, specificity, positive and negative predictive value of our scale were 100%, 94%, 4%, 100%, respectively, and AUC(area under the curve) was 0.992. In the control group, the incidence of pressure ulcers was 11(0.61%). Statistical analyses using chisquared tests with a significance level of 5%, the results were such that ${\chi }^2=3.6482$(p=0.0561). The results proved to be statistically significant in borderline. Conclusion: The results from this study proved that pressure sore risk assessment scale based on Braden scale has an excellent efficacy, and shows that our pressure ulcer prevention program is partially effective in reducing pressure ulcer incidence.

APPLICATION OF UNCERTAINTY ANALYSIS TO MAAP4 ANALYSES FOR LEVEL 2 PRA PARAMETER IMPORTANCE DETERMINATION

  • Roberts, Kevin;Sanders, Robert
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.767-790
    • /
    • 2013
  • MAAP4 is a computer code that can simulate the response of a light water reactor power plant during severe accident sequences, including actions taken as part of accident management. The code quantitatively predicts the evolution of a severe accident starting from full power conditions given a set of system faults and initiating events through events such as core melt, reactor vessel failure, and containment failure. Furthermore, models are included in the code to represent the actions that could mitigate the accident by in-vessel cooling, external cooling of the reactor pressure vessel, or cooling the debris in containment. A key element tied to using a code like MAAP4 is an uncertainty analysis. The purpose of this paper is to present a MAAP4 based analysis to examine the sensitivity of a key parameter, in this case hydrogen production, to a set of model parameters that are related to a Level 2 PRA analysis. The Level 2 analysis examines those sequences that result in core melting and subsequent reactor pressure vessel failure and its impact on the containment. This paper identifies individual contributors and MAAP4 model parameters that statistically influence hydrogen production. Hydrogen generation was chosen because of its direct relationship to oxidation. With greater oxidation, more heat is added to the core region and relocation (core slump) should occur faster. This, in theory, would lead to shorter failure times and subsequent "hotter" debris pool on the containment floor.

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Performance Optimization of a Gas-Assisted Hydraulic Breaker with Dual Stroke (가스보조식 이중행정 유압브레이커의 성능 최적화)

  • Ryoo, Taek-Jik;Chang, Hyo-Whan
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.11-19
    • /
    • 2010
  • A gas-assisted hydraulic breaker uses both hydraulic and pneumatic energies and the appropriate balance between them mostly effects its performance. Mathematical modeling of the breaker is established and verified by experiment. Through sensitivity analysis using AMESim, the key design parameters are selected, which mostly affect the performance of the breaker. Taguchi method is used to optimize the key design parameters to maximize the output power for long and short strokes through simulation. As the result, the output power as well as the impact energy are increased significantly compared with the existing design. The pressure pulsation in the supply line is reduced to a tolerable level and the dynamic characteristics of the piston displacement is also improved by the optimization.

  • PDF

Infrasonic Detection using PTFE Electret (PTFE 일렉트롯트를 이용한 초저주파 검출)

  • 김충혁;김기준;홍진웅;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1989.06a
    • /
    • pp.114-117
    • /
    • 1989
  • An infrasonic wide band transducer fabricated by polytetrafluoroethylene(PTFE)is studied experimentally. The sensitivity of the transducer depends largely on the surface charge of the Electret and is typically between-50 and -62[dBV] for a sound-pressure level of 1[ubar]. The sensitivity of the transducer does not decay over periods of the order of years at room temperature. The frequency response is within 1.5[dB] from 1 to 6,000[Hz] and within 12[dB] from 0.05[Hz] to 1[Hz] respectively. The resonance frequency of the element is 510 [Hz]. We conjectures that the element is applicable to accustics, communication system, seismological observation and other similar filed.

  • PDF

Study on Static Pressure Error Model for Pressure Altitude Correction (기압 고도의 정밀도 향상을 위한 정압 오차 모델에 관한 연구)

  • Jung, Suk-Young;Ahn, Chang-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.47-56
    • /
    • 2005
  • In GPS/INS/barometer navigation system for UAV, vertical channel damping loop was introduced to suppress divergence of the vertical axis error of INS, which could be reduced to the level of accuracy of pressure altitude measured by a pitot-static tube. Because static pressure measured by the pitot-static tube depends on the speed and attitude of the vehicle, static pressure error models, based on aerodynamic data from wind tunnel test, CFD analysis, and flight test, were applied to reduce the error of pressure altitude. Through flight tests and sensitivity analyses, the error model using the ratio of differential pressure and static pressure turned out to be superior to the model using only differential pressure, especially in case of high altitude flight. Both models were proposed to compensate the effect of vehicle speed change and used differential and static pressure which could be obtained directly from the output of pressure transducer.

Vertical Atmospheric Structure and Sensitivity Experiments of Precipitation Events Using Winter Intensive Observation Data in 2012 (2012년 겨울철 특별관측자료를 이용한 강수현상 시 대기 연직구조와 민감도 실험)

  • Lee, Sang-Min;Sim, Jae-Kwan;Hwang, Yoon-Jeong;Kim, Yeon-Hee;Ha, Jong-Chul;Lee, Yong-Hee;Chung, Kwan-Young
    • Atmosphere
    • /
    • v.23 no.2
    • /
    • pp.187-204
    • /
    • 2013
  • This study analyzed the synoptic distribution and vertical structure about four cases of precipitation occurrences using NCEP/NCAR reanalysis data and upper level data of winter intensive observation to be performed by National Institute of Meteorological Research at Bukgangneung, Incheon, Boseong during 63days from 4 JAN to 6 MAR in 2012, and Observing System Experiment (OSE) using 3DVAR-WRF system was conducted to examine the precipitation predictability of upper level data at western and southern coastal regions. The synoptic characteristics of selected precipitation occurrences were investigated as causes for 1) rainfall events with effect of moisture convergence owing to low pressure passing through south sea on 19 JAN, 2) snowfall events due to moisture inflowing from yellow sea with propagation of Siberian high pressure after low pressure passage over middle northern region on 31 JAN, 3) rainfall event with effect of weak pressure trough in west low and east high pressure system on 25 FEB, 4) rainfall event due to moisture inflow according to low pressures over Bohai bay and south eastern sea on 5 MAR. However, it is identified that vertical structure of atmosphere had different characteristics with heavy rainfall system in summer. Firstly, depth of convection was narrow due to absence of moisture convergence and strong ascending air current in middle layer. Secondly, warm air advection by veering wind with height only existed in low layer. Thirdly, unstable layer was limited in the narrow depth due to low surface temperature although it formed, and also values of instability indices were not high. Fourthly, total water vapor amounts containing into atmosphere was small due to low temperature distribution so that precipitable water vapor could be little amounts. As result of OSE conducting with upper level data of Incheon and Boseong station, 12 hours accumulated precipitation distributions of control experiment and experiments with additional upper level data were similar with ones of observation data at 610 stations. Although Equitable Threat Scores (ETS) were different according to cases and thresholds, it was verified positive influence of upper level data for precipitation predictability as resulting with high improvement rates of 33.3% in experiment with upper level data of Incheon (INC_EXP), 85.7% in experiment with upper level data of Boseong (BOS_EXP), and 142.9% in experiment with upper level data of both Incheon and Boseong (INC_BOS_EXP) about accumulated precipitation more than 5 mm / 12 hours on 31 January 2012.