• Title/Summary/Keyword: Pressure resistance

Search Result 2,182, Processing Time 0.029 seconds

A Study on the Assembly Process and Reliability of COF (Chip-On-Flex) Using ACFs (Anisotropic Conductive Films) for CCM (Compact Camera Module) (ACF를 이용한 CCM (Compact Camera Module)용 COF(Chip-On-Flex) 실장 기술 및 신뢰성 연구)

  • Chung, Chang-Kyu;Paik, Kyung-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.2
    • /
    • pp.7-15
    • /
    • 2008
  • In this paper, the Chip-On-Flex (COF) assembly process using anisotropic conductive films (ACFs) was investigated and the reliability of COF assemblies using ACFs was evaluated. Thermo-mechanical properties of ACFs such as coefficient of thermal expansion (CTE), storage modulus (E'), and glass transition temperature $(T_g)$ were measured to investigate the effects of ACF material properties on the reliability of COF assemblies using ACFs. In addition, the bonding conditions for COF assemblies using ACFs such as time, temperature, and pressure were optimized. After the COF assemblies using ACFs were fabricated with optimized bonding conditions, reliability tests were then carried out. According to the reliability test results, COF assemblies using the ACF which had lower CTE and higher $T_g$ showed better thermal cycling reliability. Consequently, thermo-mechanical properties of ACFs, especially $T_g$, should be improved for high thermal cycling reliability of COF assemblies using ACFs for compact camera module (CCM) applications.

  • PDF

Arm Armor System Performance Study: Net Effect (Perceptual Response) Analysis

  • Nam, Jin-Hee;Peksoz, Semra;Branson, Donna H.;Cao, Huantian
    • International Journal of Human Ecology
    • /
    • v.13 no.1
    • /
    • pp.117-128
    • /
    • 2012
  • This study compares the net effect of wearing different shoulder/arm armor systems on garment impediment perception and wearer acceptability. Two independent variables in this study were armor systems and shoulder/ arm movements. There were four armor systems of control garment and arm armor systems A, B, and C as well as five types of arm/shoulder movements, (shoulder flexion, should extension, shoulder abduction, shoulder horizontal flexion, and shoulder horizontal extension). Ten male volunteers wearing size medium battle dress uniform (BDU) with recent relevant military experience participated in this study. The volunteers performed shoulder/arm movements (while wearing each armor treatments) and completed the garment impediment perception as well as wearer acceptability scales. The body areas of neck side, shoulder top, and armscye front showed the highest frequency of reported impediments. Resistance to movement and localized pressure were the most frequently mentioned types of impediment. The armor system B had the most areas of impediment, and was rated as more restrictive than the control garment and armor system A for each movement. For wearer acceptability, no significant differences were found between the control garment and armor system A for all eight items; this indicated that subjects did not perceive a difference between wearing the control garment and armor system A. There was a trend for wearer acceptability to decrease from wearing the control garment to armor systems A to C to B.

Heat transfer characteristics around a circular combustion chamber of kerosene fan heater (석유 팬 히터의 연소실 주변 열전달 특성)

  • Kim, Jang-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

The effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline-induced right ventricular failure

  • Bae, Hyun Kyung;Lee, Hyeryon;Kim, Kwan Chang;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.6
    • /
    • pp.262-270
    • /
    • 2016
  • Purpose: Pulmonary arterial hypertension (PAH) leads to right ventricular failure (RVF) as well as an increase in pulmonary vascular resistance. Our purpose was to study the effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline (MCT)-induced RVF. Methods: The rats were distributed randomly into 3 groups. The control (C) group, the monocrotaline (M) group (MCT 60 mg/kg) and the sildenafil (S) group (MCT 60 mg/kg+ sildenafil 30 mg/kg/day for 28 days). Masson Trichrome staining was used for heart tissues. Western blot analysis and immunohistochemical staining were performed. Results: The mean right ventricular pressure (RVP) was significantly lower in the S group at weeks 1, 2, and 4. The number of intra-acinar arteries and the medial wall thickness of the pulmonary arterioles significantly lessened in the S group at week 4. The collagen content also decreased in heart tissues in the S group at week 4. Protein expression levels of B-cell lymphoma-2 (Bcl-2)-associated X, caspase-3, Bcl-2, interleukin (IL)-6, matrix metalloproteinase (MMP)-2, endothelial nitric oxide synthase (eNOS), endothelin (ET)-1 and ET receptor A (ERA) in lung tissues greatly decreased in the S group at week 4 according to immunohistochemical staining. According to Western blotting, protein expression levels of troponin I, brain natriuretic peptide, caspase-3, Bcl-2, tumor necrosis factor-${\alpha}$, IL-6, MMP-2, eNOS, ET-1, and ERA in heart tissues greatly diminished in the S group at week 4. Conclusion: Sildenafil alleviated right ventricular hypertrophy and mean RVP. These data suggest that sildenafil improves right ventricular function.

Joining Technology of Flat Panel Photobioreactor Case (평판형 광생물반응기 케이스 접합 기술)

  • Ahn, Dong-Gyu;Lee, Ho Jin;Ahn, Yeong-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.154-163
    • /
    • 2013
  • Adhesive bonding and plastic welding have been widely used to join two plastic materials together. The goal of this paper is to determine a proper joining technology of a pair of flat panel (FP) photobioreactor (PBR) case. The material of the FP PBR case is polycarbonate (PC) plate. Two types of adhesion, including acryl adhesive and two-part epoxy adhesive, as well as two types of plastic welding technology, including ultrasonic welding and thermal welding, are employed for joining of PC plates. In order to influence of the adhesion and welding conditions on the joining characteristics of the PC plates in operational conditions of the FP PBR case, the morphology in the vicinity of the joined region as well as the water and pressure resistance characteristic are investigated. In addition, the variation of the bonding strength of the joined region and deformation behaviors in the vicinity of the joined region according to the adhesion and welding conditions is examined via the lap-shear test. From the results of basic experiments, proper joining technologies are chosen. Using the chosen joining technologies, the FP PBR case are fabricated to perform full-scale durability experiment. The results of the full-scale durability experiment have been shown that the chosen joining technologies can be applicable to fabricate the FP PBR case.

Generation of Fine Droplets in a Simple Microchannel (유체 소자를 이용한 미세 액적 생성)

  • Kim, Su-Dong;Kim, Young-Won;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.671-677
    • /
    • 2010
  • In the present study, we designed a microfluidic platform for generating monodisperse droplets with diameters ranging from hundreds of nanometers to several micrometers. To generate fine droplets, T-junction and flow-focusing geometry are integrated into the microfluidic channel. Relatively large aqueous droplets are generated at the upstream T-junction and transported to the flow-focusing geometry, where each droplet is broken into smaller droplets of the desired size by the action of pressure and viscous stress. In this configuration, the flow rate of the inner fluid can be made very low, and the ratio of the inner- and outer-fluid flow rates in the flow-focusing region can be made very high. It has been shown that the present microfluidic device can generate droplets with diameters of approximately $1\;{\mu}m$ (standard deviation: <3%).

Flow Rate Prediction of Pneumatic Pipe System Using Concept of Conductance (컨덕턴스의 개념을 사용한 공압관 시스템의 유량 예측)

  • Kim, Jin-Hyeon;Deng, Ruoyu;Kim, Heuy-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.431-436
    • /
    • 2014
  • Conductance is a concept contrary to flow resistance and is extensively used as a flow index on how easily fluid is transported through a pneumatic pipe or fluid device. However, research on flow conductance is very rare to date, and a systematic investigation is needed for the standardization of pneumatic devices. In the present study, a computational fluid dynamics method was applied to solve the compressible Navier-Stokes equations with two-equation turbulence models. The present CFD results were validated with existing experimental data. The conductance values and friction factors at the inlet and outlet of a pneumatic pipe were used to assess the flow rates. The present results showed that the conductance depends on the pressure ratio at the inlet and outlet of a pipe.

Structural health monitoring of a newly built high-piled wharf in a harbor with fiber Bragg grating sensor technology: design and deployment

  • Liu, Hong-biao;Zhang, Qiang;Zhang, Bao-hua
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-173
    • /
    • 2017
  • Structural health monitoring (SHM) of civil infrastructure using fiber Bragg grating sensor networks (FBGSNs) has received significant public attention in recent years. However, there is currently little research on the health-monitoring technology of high-piled wharfs in coastal ports using the fiber Bragg grating (FBG) sensor technique. The benefits of FBG sensors are their small size, light weight, lack of conductivity, resistance corrosion, multiplexing ability and immunity to electromagnetic interference. Based on the properties of high-piled wharfs in coastal ports and servicing seawater environment and the benefits of FBG sensors, the SHM system for a high-piled wharf in the Tianjin Port of China is devised and deployed partly using the FBG sensor technique. In addition, the health-monitoring parameters are proposed. The system can monitor the structural mechanical properties and durability, which provides a state-of-the-art mean to monitor the health conditions of the wharf and display the monitored data with the BIM technique. In total, 289 FBG stain sensors, 87 FBG temperature sensors, 20 FBG obliquity sensors, 16 FBG pressure sensors, 8 FBG acceleration sensors and 4 anode ladders are installed in the components of the back platform and front platform. After the installation of some components in the wharf construction site, the good signal that each sensor measures demonstrates the suitability of the sensor setup methods, and it is proper for the full-scale, continuous, autonomous SHM deployment for the high-piled wharf in the costal port. The South 27# Wharf SHM system constitutes the largest deployment of FBG sensors for wharf structures in costal ports to date. This deployment demonstrates the strong potential of FBGSNs to monitor the health of large-scale coastal wharf structures. This study can provide a reference to the long-term health-monitoring system deployment for high-piled wharf structures in coastal ports.

Antihypertensive and Cardiovascular Effects of the New Calcium Antagonist YH334

  • Lee, Jong-Wook;Han, Byung-Hee;Lee, Jeong-Won;Seok, Ji-Hee;Kim, Su-Chang;Hong, You-Hwa;HongSuh, Jung-Jin;Hong, Soon-Uk
    • Archives of Pharmacal Research
    • /
    • v.14 no.3
    • /
    • pp.242-248
    • /
    • 1991
  • Antihypertensive effect of YH 334 was examined in various experimental hypertension rat models and the systemic and regional hymohynamic profiles of the compound were investigated in conscious spontaneously hypertensive rats (SHR). The antiypertensive potensive potency of YH 334 is found to be more than 10 times stronger than that of nitrendipine in the all hypertensive models. The effective doses to lower the initial blood pressure by 20% $(ED_{20})$ of YH334 were 1.4 mg/kg in normotensive rats (NR), 0.7 mglkg in SHR. 0.1 mg/kg in DOCA salt hypertensive rats (DHR) and 0.4 mg/kg in renal hypertensive rats (RHR), and the $ED_{20}$ values of nitrendipine were 15.8 mg/kg in NR, 7.1 mg/kg in SHR, 1.7 mg/kg in DHR and 4.8 mg/kg in RHR. The primary hemodynamic effect hemodynamic profile is similar to that of nitrendipine. Both compounds seem to produce potent antihypertensive effects by lowering peripheral resistance in the skeletal muscles. In the organ bath study using isolated rabbit aorta, YH 334 was found to be a potent voltage dependent calcium channel blocker without significant inhibitory effect on the receptor operated calcium channels like the most of other dihydropyridine type calcium antagonists. Furthermore, YH334 showed acute diuretic and natriuretic effects in conscious SHR, which may render the unnecessary restriction of sodium in the diet of those patients on long term hypertension therapy. This effect would provide an additional benefit to its potent antihypertensive activity.

  • PDF

The Reduction Case of Occurrence of Abnormal Wearing of Rail in Compound Curve Part (복심곡선 레일이상마모 발생 저감 사례)

  • Kim, Wan-Sool
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1097-1106
    • /
    • 2007
  • Rail provides running tract for train and broadly and widely conveys the weight of the train exerted from the train wheels that the rail directly supports onto the cross tie and roadbed, and supports the cross-sectional pressure exerted by centrifugal force at curvatures. That is, stationary rail provides surface on which dynamic train runs and guarantees cross-sectional resistance to enable the vertical snake motion of the train wheels as well as to maintain lateral force at curvatures. Rail provides running surface on which train wheels can run smoothly, and secures vertical and lateral force. However, it undergoes continuous destructive reactions (wearing and damages) and abrasion of the cladding by the train wheels. It is obvious that wearing will result when two metal parts act against each other. However, occurrence of abnormal wearing such as rapid wearing of the rail side due to complex generation of various mechanisms at the contact surface between the rail and train wheel flange. It is not easy to simply examine the causes of occurrence of abnormal wearing of rail and train wheel flange. Although countless number of academicians and specialists are conducting researches on abnormal wearing of rail and vertical wearing of train wheels, I believe it is too early to argue on pros and cons due to insufficiency of officially verified information on the issue. This review will be focusing on the examples of repairs that reduced the generation of abnormal wearing of rail by reviewing and improving characteristics of wearing and slack, speed of the train and cant as well as status of lubricator by choosing the compound curves present in the section between the $Anguk{\sim}Jongno3-ga$ Stations of the Route No. 3 among the compound curve tracks of the Seoul Metro Routes No. 3 & 4 at which abnormal wearing is generated continuously.

  • PDF