• 제목/요약/키워드: Pressure op

검색결과 35건 처리시간 0.023초

협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예 (Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제12권1호
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

조리방법에 따른 쌀밥에 관능적 성질 및 휘발성 성분에 관한연구 (Sensory Characteristics and Volatile Compounds of Cooked Rice according to the Various Cook Method)

  • 송재철
    • 한국식품영양학회지
    • /
    • 제12권2호
    • /
    • pp.142-149
    • /
    • 1999
  • Moisture absorption rate of rice according to the soaking time was higher at $25^{\circ}C$ than 4$^{\circ}C$ and the op-timum soaking time was 1hr at $25^{\circ}C$. When the ratios of added water for rice cooking were 1.3 in an elec-tric cooker and pressure cooker and 1.7 in an Dookbaeki sensory an mechanically evaluation of cooked rice were highly evaluated. The total number of peak on gas chromatography profile were 89 in an press-ure cooker 56 in an electric cooker and 83 in an Dookbaeki and major volatile compounds of cooked rice were aliphatic hydrocarbons cyclic hydrocarbons aromatic hydrocarbons aldehydes alcohols ketones and thiourea. Furan that is in sweety was not detected in volatile components of cooked rice of electric cooker.

  • PDF

선천성 대동맥 판막 협착증 치험 2예 (Congenital Aortic Stenosis: Report of 2 Cases)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제11권2호
    • /
    • pp.194-198
    • /
    • 1978
  • Congenital aortic stenosis, a relatively uncommon congenital heart disease, may cause heart failure and may be fatal. In recent years, increased clinical awareness and improved diagnostic and operative technique has made accurate diagnosis and successful treatment possible. Recently we experienced 2 cases of congenital aortic stenosis, and which was corrected surgically. The first case was 9 years old boy, and second case was 16 years male. Preoperative diagnosis was entertained by angiography and cardiac catheterization in both cases. In each case, aortic valve opening was widened by incision along the fused commissure between the combined left and right coronary cusp on one side, and the noncoronary cusp on the other side. Post-op. pressure gradient between the aorta and left ventricle markedly reduced, in the first case, 50mmHg, and in the 2nd case, 55mmHg.Both patients discharged with good results 2 weeks after open heart surgery.

  • PDF

PVDF 압전소자를 이용한 심장박동 및 호흡수 동시측정센서개발 (Development of New Stacked Element Piezoelectric Polyvinylidene Fluoride Pressure Sensor for Simultaneous Heartbeat and Respiration Measurements)

  • 박창용;권현규;이소진;롱원만
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.100-108
    • /
    • 2019
  • In this paper, a new stacked element pressure sensor has proposed for heartbeat and respiration measurement. This device can be directly attached to an individual's chest; heartbeat and respiration are detected by the pulsatile vibration and deformation of the chest. A key feature of the device is the simultaneous measurement of heart rate and respiration. The structure of the sensor consists of two stacked elements, in which one element includes one polyvinylidene fluoride (PVDF) thin film bonded on polydimethylsiloxane (PDMS) substrate. In addition, for the measurement and signal processing, the electric circuit and the filter are simply constructed with an OP-amp, resistance, and a capacitor. One element (element1, PDMS) maximizes the respiration signal; the other (element2, PVDF) is used to measure heartbeat. Element1 and element2 had sensitivity of 0.163V/N and 0.209V/N, respectively, and element2 showed improved characteristics compared with element1 in response to force. Thus, element1 and element2 were optimized for measuring respiration heart rate, respectively. Through mechanical and vivo human tests, this sensor shows the great potential to optimize the signals of heartbeat and respiration compared with commercial devices. Moreover, the proposed sensor is flexible, light weight, and low cost. All of these characteristics illustrate an effective piezoelectric pressure sensor for heartbeat and respiration measurements.

구조화된 수술 전 교육이 백내장 수술 환자의 불안과 자가간호 수행에 미치는 효과 (The Effects of Structured Preoperative Instruction on Anxiety and Self-care Compliance in Patients with Cataract Surgery)

  • 최미정;박정숙
    • 성인간호학회지
    • /
    • 제25권4호
    • /
    • pp.473-482
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effects of a structured preoperative instruction upon anxiety and postoperative self-care compliance. Methods: A randomized control group pre-post design was used. Sixty subjects undergoing cataract surgery were randomly assigned to one of two groups. The instruction consisted of cataract surgery procedure, sensory information, deep breathing, use of eye drop, and post op self-care regimen and was provided to the experimental group with control group receiving an usual treatment. State anxiety NRS, pulse, BP, and self-care compliance scale developed by Cho & Rho were used. Data were collected at two time periods: on the day of surgery in the clinic and prior to anesthesia in the operating room. The postoperative self-care compliance scores were measured at their second visits to the hospital after surgery. Data were analyzed using Kolmogorov Smirnov test, t-test, and Mann-Whitney U test. Results: There were significant differences between the two groups in the postoperative state anxiety (t=-3.57, p=.001) and the postoperative self-care compliance score (t=3.92, p<.001). There were no significant difference between the two groups in the postoperative blood pressure and pulse rate. Conclusion: The results of this study suggest that the structured preoperative instruction could be a nursing intervention for cataract surgery patients.

악교정 수술 후 발생하는 신경회복에 대한 연구 I (PRELIMINARY STUDY OF NEUROSENSORY RECOVERY AFTER BSSRO)

  • 이동근;조이수;민승기;오승환;정창주;이은택
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제23권2호
    • /
    • pp.144-154
    • /
    • 2001
  • Dysfunction of the inferior alveolar nerve indicated by various degree of numbness of the lower lip and chin is one of the few drawbacks of mandibular osteotomy, especially Bilateral Sagittal Split Ramus Osteotomy(BSSRO) and genioplasty. Although it has been recorded throughout the history of this techniques, it is true etiology poorly understood. In this study, 22 consecutive patients under class III malocclusiion impression and undergoing orthognathic surgery(BSSRO only 11 case, BSSRO with genioplasty 11 case) were studied using 4 neurosensory test(static light touch, directional discrimination, two-point discrimination, pin pressure nociception) with post OP 1 week, 2 weeks, 4 weeks, 8 weeks, 12 weeks, 24 weeks, On control group, 10 members without trauma and nerve damage history, nerve test was accomplished. We concluded majority of patients return of sensation during post operative 24 weeks. Althought immediate nerve deficit are 92.2%, 97.2% 88.9% these are recovered to 25%, 35.72%, 10.71% at 24 weeks. Nerve recovery rate increased prominently between post 4 weeks and 8 weeks. There is no statistically difference about neurosensory deficit among the chin area. Neurosensory deficit more severe when the BSSRO with genioplasty group than the only BSSRO group. Immediate neurosensory deficit is larger left side than right side but after 6 months, there is no significantly difference between left side and right side. Static light touch and pin pressure nociception are more sensitive method of neurosensory deficit than two point discrimination.

  • PDF

Changes of Cerebral Metabolism and the Related Factors during Cardiac Surgery

  • Park, Seok-Cheol
    • 대한의생명과학회지
    • /
    • 제8권3호
    • /
    • pp.143-154
    • /
    • 2002
  • The effect of cardiopulmonary bypass (CPB) on cerebral physiology during heart surgery remains incompletely understood. This study was carried out to investigate changes of cerebral metabolism and the association between the changes and clinical factors during heart surgery. Seventy adult patients (n=70) scheduled for elective cardiac surgery were participated in the present study. Middle cerebral artery blood flow velocity (V$_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v)O$_2$), cerebral oxygen extraction (COE), and modified cerebral metabolic rate for oxygen (MCMRO$_2$) were measured during six phases of the operation; Pre-CPB, CPB-10 min, Rewarm-1 (nasopharyngeal temperature 34$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), CPB-off, and Post-OP (at skin closure after CPB-off). Each relationship of age, arterial blood gas parameters, or other variables to V$_{MCA}2$, C(a-v)O$_2$, COE, or MCMRO$_2$ was evaluated. V$_{MCA}$ increased (P<0.0001) whereas C(a-v)O$_2$ decreased (P<0.01) throughout the five phases of the operation compared to Pre-CPB value (control). COE diminished at CPB-10, Rewarm-1, and CPB-off (P<0.05) while MCMRO$_2$ reduced at CPB-10 and Rewarm-1 (P<0.05) compared to Pre-CPB value. Positive correlation was found between age and cerebral metabolic parameters (V$_{MCA}$, C(a-v)O$_2$, COE, or MCMRO$_2$) during CPB (range r=0.24 to 0.38, p<0.05). Four cerebral metabolic parameters had partially negative or positive correlation with arterial blood gas parameters and other variables (arterial blood pH, $O_2$ tension, $O_2$ content, $CO_2$ tension, blood pressure, blood flow, temperature, or hematocrit) during the operation. In conclusion, CPB led to marked alterations of cerebral metabolism and age, pH, and $CO_2$ tension profoundly influenced the changes during cardiac surgery.

  • PDF

혼합냉매의 열역학적 물성치 추산에 관한 연구 (Studies on the Estimation of Theromodynamic Properties for the Non-Azeotropic Refrigerant Mixtures)

  • 김민수;김동섭;노승탁;김욱중;윤재호
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1337-1348
    • /
    • 1990
  • 본 연구에서는 Peng-Robinson 상태 방정식을 기본으로 하여 먼저 단일 성분의 냉매에 대한 열역학적 물성치를 구한 뒤 그 정확도를 검증하고, 동일한 형태의 상태식 과 적절한 혼합 법칙을 통해 혼합냉매의 기액 평형 상태와 냉동 및 열펌프 사이클 해 석에 필요한 엔탈피와 엔트로피 등의 열역학적 물성치를 추산하고자 한다.단일 성 분의 냉매로서는 R13B1, R22, R12, R152a, R114를 택하였고, 혼합냉매로서는 앞의 단 일성분 냉매를 혼합한 것 중에서 그 기초적인 실험 자료가 아미 알려진 R13B1/R114, R22/R114, R12/R114 R152a/R114, R13B1/R152a 및 R13B1/R12를 택하였다. 이는 추후 상이한 냉매를 단일식으로 나타낼 수 있는 대응상태의 원리를 사용한 열물성 계산의 기반이 될 수 있을 것이다.

한발저항성 정도가 다른 보리 품종들의 한발처리에 따른 생리적 특성변화 (Changes in Physiological Characteristics of Barley Genotypes under Drought Stress)

  • 이변우;부금동;백남천;김정곤
    • 한국작물학회지
    • /
    • 제48권6호
    • /
    • pp.506-515
    • /
    • 2003
  • 이 논문은 한발저항성이 다른 6개 보리 품종의 한발에 따른 생장, 잎의 수분포텐셜(leaf water potential, LWP), 상대함수량(leaf relative water content, RWC), 삼투압(leaf osmotic potential, OP), 삼투조정(osmotic adjustment, OA), 팽압(leaf turgor pressure, LTP), 순광합섬, 기공전도도, 엽육전도도, 엽록소형광 등의 변화를 조사하여 비교한 결과를 요약하면 다음과 같다. 1 한발 처리시 토양수분포텐셜은 -0.05㎫이었고. 종료시에는 -0.29㎫로 저하하였다. Dicktoo-S 동보리 1호, Dicktoo-L, Dicktoo-T, 수원쌀보리 365호, 탑골보리 품종의 한발처리구 건물중은 각각 대조구(처리기간종 -0.05㎫ 유지)에 비하여 68%, 69%, 70%, 86%, 55%, 37%를 나타내어 Dicktoo 계통과 동보리1호의 한발저항성이 강하였고, 수원쌀보리 365호와 탑골보리는 한발저항성이 약하였다. 2. 한발저항성이 강한 품종은 삼투조정능력이 커서 한발처리에 따른 RWC와 LWP의 저하가 작았고 팽압유지능력이 컸다. 3. 한발처리에 따라 순광합성이 저하하였고 그 저하정도는 한발저항성이 큰 품종이 작았는데, 이는 한발저항성이 큰 품종이 기공전도도, 엽육전도도 및 PSII 최대양자수율(Fv/Fm)의 저하가 적었기 때문이었다. 4. 결론적으로 저항성이 큰 품종은 삼투조정에 의한 수분유지능력이 크고 이에 따라 광합성저하가 적어 상대적으로 생장의 감소가 적은 것으로 판단되었다.

Integra®를 이용한 화상 반흔 구축 재건에 있어 Vacuum-Assisted Closure(VAC)의 유용성 (Acceleration of Integra Incorporation in Reconstruction of Burn Scar Contracture with The Vacuum-Assisted Closure(VAC))

  • 오석준;전만경;고성훈
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.432-436
    • /
    • 2009
  • Purpose: Negative pressure therapy has been used in various conditions to promote wound healing. It has also been used to secure a skin graft by improving microcirculation and improving tight adhesion between the graft and the recipient bed. To reduce post burn scar contracture and improve aesthetical result, many types of dermal substitutes have been invented and used widely. The goal of this study was evaluate usefulness of the VAC (Kinetic concepts Inc., San Antonio, TX) in improving the take rate and time to incorporation of Integra$^{(R)}$ in reconstruction of burn scar contracture. Methods: A retrospective study was performed from October, 2006 to December, 2008. The VAC was utilized for 11 patients. The average patient's age was 19.7 years (range 5 - 27) and average surface area was $785cm^2$ (range 24 - 1600). The burn scars were excised deep into normal subcutaneous tissue to achieve complete release of the scar, Integra$^{(R)}$ was sutured in place with skin staple와 Steri - strip$^{(R)}$. Then slit incisions were made on silicone sheet only with No.11 blade for effective drainage. The VAC was used as a bolster dressing over Integra$^{(R)}$. Negative - Pressure ranging from 100 to 125 mm Hg was applied to black polyurethane foam sponge trimmed to the appropriate wound size. An occlusive seal over the black polyurethane foam sponge was maintained by a combination of the occlusive dressing, OP - site$^{(R)}$. The VAC dressing changes were performed every 3 or 4 days until adequate incorporation was obtained. The neodermis appeared slightly yellow to orange color. When the Integra$^{(R)}$ deemed clinically incorporated, The VAC was removed and take was estimated with visual inspection. Very thin STSG(0.006 ~ 0.008 inches) was performed after silicone sheet removal. Result: The mean time for clinically assessed incorporation of Integra$^{(R)}$ was 10.00 days (range 9 - 12). The mean dressing change was 3.5 times until take was obtained. In All patients, Integra$^{(R)}$ had successful incorporation in tissue without serious complications. Conclusion: Integra$^{(R)}$ in combination with Vacuum - Assisted Closure(VAC) may be incorporated earlier than conventional dressing method.