• 제목/요약/키워드: Pressure monitoring

검색결과 1,096건 처리시간 0.023초

Monitoring System of Agriculture Fields using ZigBee Modules

  • Ayurzana, Odgerel;Tsagaanchuluun, Sugir
    • International journal of advanced smart convergence
    • /
    • 제10권1호
    • /
    • pp.89-96
    • /
    • 2021
  • The goal of this study is to develop experiment monitoring system of agriculture fields using ZigBee wireless modules. Soil moisture, ambient temperature, atmospheric pressure and intensity of sunlight are the most important factorsto grow a wheat crop and other vegetables. In orderto monitorthe factorssoil moisture (YL69), air pressure (BMP180), temperature (DS18B20), photoresistor were used for sensing environment data. The TI CC2530 RF SoC chip was used in the system. ZigBee modules were connected to star topology. ZigBee modules send data wirelessly to a data center. This data can be displayed and analyzed on the main monitoring program as needed also sent to the client mobile. Characteristics of the sensors were determined by experiment results.

Current Status of Intracranial Pressure Monitoring in Patients with Severe Traumatic Brain Injury in Korea : A Post Hoc Analysis of Korea Neurotrauma Databank Project with a Nationwide Survey

  • Youngheon Lee;Jung Hwan Lee;Hyuk Jin Choi;Byung Chul Kim;Seunghan Yu;Mahnjeong Ha;The KNTDB Investigators
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권5호
    • /
    • pp.543-551
    • /
    • 2023
  • Objective : This study aimed to investigate the current status of intracranial pressure (ICP) monitoring in patients with severe traumatic brain injury (sTBI) in Korea and the association between ICP monitoring and prognosis. In addition, a survey was administered to Korean neurosurgeons to investigate the perception of ICP monitoring in patients with sTBI. Methods : This study used data from the second Korea Neurotrauma Databank. Among the enrolled patients with sTBI, the following available clinical data were analyzed in 912 patients : Glasgow coma scale score on admission, ICP monitoring, mortality, and extended Glasgow outcome scale score at 6 months. In addition, we administered a survey, entitled "current status and perception of ICP monitoring in Korean patients with sTBI" to 399 neurosurgeons who were interested in traumatic brain injury. Results : Among the 912 patients, 79 patients (8.7%) underwent ICP monitoring. The mortality and favorable outcome were compared between the groups with and without ICP monitoring, and no statistically significant results were found. Regarding the survey, there were 61 respondents. Among them, 70.4% of neurosurgeons responded negatively to performing ICP monitoring after craniectomy/craniotomy, while 96.7% of neurosurgeons responded negatively to performing ICP monitoring when craniectomy/craniotomy was not conducted. The reasons why ICP monitoring was not performed were investigated, and most respondents answered that there were no actual guidelines or experiences with post-operative ICP monitoring for craniectomy/craniotomy. However, in cases wherein craniectomy/craniotomy was not performed, most respondents answered that ICP monitoring was not helpful, as other signs were comparatively more important. Conclusion : The proportion of performing ICP monitoring in patients with sTBI was low in Korea. The outcome and mortality were compared between the patient groups with and without ICP monitoring, and no statistically significant differences were noted in prognosis between these groups. Further, the survey showed that ICP monitoring in patients with sTBI was somewhat negatively recognized in Korea.

Flexible wireless pressure sensor module

  • Shin Kyu-Ho;Moon Chang-Ryoul;Lee Tae-Hee;Lim Chang-Hyun;Kim Young-Jun
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2004년도 추계 기술심포지움 초록집
    • /
    • pp.3-4
    • /
    • 2004
  • A flexible Packaging scheme, which embedded chip packaging, has been developed using a thinned silicon chip. Mechanical characteristics of thinned silicon chips are examined by bending test and finite element analysis. Thinned silicon chips ($t<50{\mu}m$) are fabricated by chemical etching process to avoid possible surface damages on them. These technologies can be use for a real-time monitoring of blood pressure. Our research targets are implantable blood pressure sensor and its telemetric measurement. By winding round the coronary arteries, we can measure the blood pressure by capacitance variation of blood vessel.

  • PDF

Development of an automated system for water-hydraulic and leakage test of pressure vessels

  • Kim, Dong-Soo;Lee, Won-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권1호
    • /
    • pp.55-59
    • /
    • 2004
  • This study developed a fully automated test system for pressure vessels, containing such as oxygen, nitrogen, which is widely used in many industries. The pressure vessel test has three major parts including weight measurement test, water-hydraulic test and leakage test followed by cleaning and drying. The control system for these tests consists of three parts: a PLC, a monitoring system and a database management system. The PLC oversees overall control of test machines, while the monitoring system measures and displays weight, pressure, flow etc. for every situations, and the database management system stores test data. These three modules are designed to communicate with one another at 1 Hz frequency alerting problematic situations to the operator. The system has gone through actual field tests for verification of performances.

Significance of Intracranial Pressure Monitoring after Early Decompressive Craniectomy in Patients with Severe Traumatic Brain Injury

  • Kim, Deok-Ryeong;Yang, Seung-Ho;Sung, Jae-Hoon;Lee, Sang-Won;Son, Byung-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권1호
    • /
    • pp.26-31
    • /
    • 2014
  • Objective : Early decompressive craniectomy (DC) has been used as the first stage treatment to prevent secondary injuries in cases of severe traumatic brain injury (TBI). Postoperative management is the major factor that influences outcome. The aim of this study is to investigate the effect of postoperative management, using intracranial pressure (ICP) monitoring and including consecutive DC on the other side, on the two-week mortality in severe TBI patients treated with early DC. Methods : Seventy-eight patients with severe TBI [Glasgow Coma Scale (GCS) score <9] underwent early DC were retrospectively investigated. Among 78 patients with early DC, 53 patients were managed by conventional medical treatments and the other, 25 patients were treated under the guidance of ICP monitoring, placed during early DC. In the ICP monitoring group, consecutive DC on the other side were performed on 11 patients due to a high ICP of greater than 30 mm Hg and failure to respond to any other medical treatments. Results : The two-week mortality rate was significantly different between two groups [50.9% (27 patients) and 24% (6 patients), respectively, p=0.025]. After adjusting for confounding factors, including sex, low GCS score, and pupillary abnormalities, ICP monitoring was associated with a 78% lower likelihood of 2-week mortality (p=0.021). Conclusion : ICP monitoring in conjunction with postoperative treatment, after early DC, is associated with a significantly reduced risk of death.

원심모형시험을 이용한 필댐 취약부 모니터링 (Monitoring of Fill Dams for Internal Defect via Centrifuge Model Tests)

  • 추연욱;조성은;신동훈
    • 대한토목학회논문집
    • /
    • 제32권2C호
    • /
    • pp.37-47
    • /
    • 2012
  • 본 연구에서는 필댐을 위한 모니터링 기술에 적용할 수 있는 물리량으로 간극수압, 온도와 전기저항을 선정하였고, 이를 원심모형시험 상에서 계측할 수 있는 시스템을 구축하였다. 또한, 코아형 필댐 모형 단면을 설계하고, 코아죤에 취약부가 없는 정상적인 경우, 코아죤 하부에 부분적인 취약부가 발생한 경우, 코아죤 하부에 취약부가 커져서 상하류 사력죤이 연결되는 경우를 포함하여, 총 세 가지 모형을 제작하고, 원심모형시험을 수행하였다. 원심력장이 작용하는 조건에서, 담수시에 나타나는 침투 흐름의 변화에 따라 간극수압, 온도 및 전기저항의 변화를 모니터링하였다. 원심모형시험을 통하여, 간극수압, 온도 및 전기저항의 변화가 취약부 존재에 따라 다르게 나타나는 것을 확인할 수 있었고, 간극수압, 온도와 전기 저항이 필댐의 내부 취약부를 탐지하기 위한 모니터링 기술 개발에 적용될 수 있음을 확인하였다.

월성1호기 계속운전 관련 결함연료위치탐지계통 배관의 열화관리평가 (Assessment on Aging Management of Delayed Neutron Monitoring System Tubing for Continued Operation of Wolsong Unit 1)

  • 송명호;김홍기;이영호
    • 한국압력기기공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.14-20
    • /
    • 2011
  • The end of design lifetime for Wolsong unit 1 will be reached on 20th November in 2012. So the license renewal documents for the continuous operation of Wolsong unit 1 is under reviewing now. Major components of primary system such as pressure tubes, feeder pipes including delayed neutron monitoring system tubing are being replaced and many components of secondary system are also being repaired. In this paper, the assessment on the wear degradation of delayed neutron monitoring system tubing(on the other hand, DN tube was called) was performed for the ageing management of the same component. The wear defects of this component was one of causes that resulted in heavy water leakage accidents. Therefore design specifications of Wolsong uint 1 and heavy water leakage accidents of pressurized heavy water reactors were reviewed and causes of wear defect for DN tubes were analyzed. Wear propagation equations based on the heavy water leakage history were made and the proper repairing time was possible to be expected if the continued operation was considered. Finally design change items of DN tubes that were conducted for the long term operation of Wolsong unit 1 are introduced.

Effectiveness of e-health systems in improving hypertension management and awareness: a systematic review

  • Alotaibi, Mohamed;Ammad uddin, Mohammad
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제16권1호
    • /
    • pp.173-187
    • /
    • 2022
  • Recent studies have focused on self-management of hypertension using smart devices (cellular phones, tablets, watches). It has proven to be an effective tool for early detection and control of high Blood Pressure (BP) without affecting patients' daily routines. This systematic review surveys the existing self-monitoring systems, evaluate their effectiveness and compares the different approaches. We investigated the current systems in terms of various attributes, including methods used, sample size, type of investigation, inputs/ outputs, rate of success in controlling BP, group of users with higher response rate and beneficiaries, acceptability, and adherence to the system. We identified some limitations, shortcomings, and gaps in the research conducted recently studying the impact of mobile technology on managing hypertension. These shortcomings can generate future research opportunities and enable it to become more realistic and adaptive. We recommended including more observable factors and human behaviors that affect BP. Furthermore, we suggested that vital monitoring/logging and medication tuning are insufficient to improve hypertension control. There is also a need to observe and alter patient behavior and lifestyles.

해양 응급상황 알림을 위한 TPMS 디바이스와 모바일 앱 시스템 개발 (Development of TPMS Device and Mobile App System for Marine Emergency Notification)

  • 공동환
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권3호
    • /
    • pp.49-53
    • /
    • 2024
  • 해양 안전은 바다에서의 사고로부터 인명을 보호하고, 보다 안전한 해양 환경을 조성하는 데 중요한 요소다. 본 연구에서는 해양 안전을 향상시키기 위한 TPMS 디바이스를 개발하고, 이를 통해 바다에서의 사고 상황을 감지하고 신속한 대응을 가능케 하는 기술적 솔루션을 제시한다. 이를 위해 개발한 튜브 압력 측정 시스템(TPMS)을 활용하여 튜브의 팽창을 감지하고, 실시간으로 데이터를 수집하여 주변 기기와 통신함으로써 빠른 대응이 가능하도록 설계되었다. 실험 결과를 통해 TPMS(Tube Pressure Monitoring System)가 효과적으로 압력을 감지하고, Main IoT 디바이스와 통신하며 안정적인 데이터 송수신이 가능함을 확인하였다. 또한 비상 상황에 빠르게 대응할 수 있도록 비상 상황 알림 메시지를 수신하고 정보를 조회할 수 있는 모바일 앱을 개발하였다. 개발한 디바이스와 모바일 앱은 해양 안전 분야뿐만 아니라 다양한 응용 분야에서도 활용 가능한 기술을 포함하고 있으며, 향후에는 실제 현장에서의 적용 가능성을 확대할 것이다. 이러한 결과는 해양 환경의 안전성을 높이는 데 기여할 것으로 기대된다.

가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구 (A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent)

  • 고아라;임동오;손봉세
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.103-110
    • /
    • 2016
  • 가스계소화설비의 수요는 매해 증가하고 있으나, 늘어나는 수요에 대비한 시스템의 안전성 및 신뢰성등 소화성능에 필요한 안전대책이 미흡하여 사회적인 문제가 되고 있는 실정이다. 본 연구에서는 이러한 문제점을 해결하기 위하여 가스 소화시스템의 사고발생 원인 중에서 가장 심각한 문제인 소화약제 저장용기에서 발생하는 압력누기는 화재진압의 성패를 좌우하는 중요한 요소로 시급한 대책이 요구되는 문제점로 판단하여 연구를 하였다. 새로 개발한 압력누기감시장치는 화재진압에 중요한 요소인 소화농도와 관련이 있는 저장용기의 약제확보상태와 압력 및 누기, 방출상태 등을 감시하는 장치로 $CO_2$와 HFC-23 시스템에 적용할 수 있도록 개발하였다. 즉, 압력누기감시장치를 가스소화설비에 적용하였을 때 발생할 수 있는 구조적 안전성 분석을 위하여 유체-구조연계해석을 통하여 안전성능을 검증하였다. 해석에 사용한 프로그램으로 전산유체해석은 Mentor Graphics사의 FloEFD 프로그램을 사용하였고, 구조해석 프로그램은 Dassault systems사의 ABAQUS를 사용하였다. 수치해석결과 $CO_2$용의 구조에서는 소성변형이 발생하지 않아 안전성을 확인하였으나 HFC-23용 감시장치에는 소성변형 및 이탈문제가 발생하여 설계수정과 3차례의 수치해석 조건을 수정하여 얻은 데이터를 기본으로 압력누기감시장치의 구조적인 안전성을 확인하였다.