• Title/Summary/Keyword: Pressure measurement systems

Search Result 280, Processing Time 0.027 seconds

An Efficient Water Pressure Measurement System of the Water Pipes using IoT (IoT를 이용한 상수도관의 효율적인 수압 측정 시스템)

  • Lee, Jae-soo;Choi, In-ho;Hong, Kwon-eui;Choi, Hak-yun;Roh, Hee-jung;Ahn, Jeong-keun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.1
    • /
    • pp.114-122
    • /
    • 2018
  • In this paper, we propose new water pressure measurement system to measure the water pressure of water pipe laid underground beneath the manhole efficiently. For this purpose, we installed water pressure sensor(IoT) which has built-in bluetooth module at valve of water pipe. The proposed system can be managed through collected data which measured at sensor and then transmitted to smart phone through bluetooth connectivity and re-transmitted to server on this system. By checking out water pressure data stored in server from remote location, the persons in charge can confirm the leakage of water pipe or propriety of water pressure in management area. By this procedure, they can detect the existence of condition of water pipe and manage water pressure of water pipe efficiently.

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

Analysis of Blood pressure influence factor Correction for Photoplethysmography Fusion Algorithm Calibration (광전용적맥파 융합 알고리즘 보정을 위한 혈압 영향인자 상관관계 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • The blood pressure measurement is calculated as a value corresponding to the pressure of the blood vessel using the pressure from the outside for a long time. Due to the recent miniaturization of measurement equipment and the ICT combination of personal healthcare systems, a system that enables continuous and real-time measurement of blood pressure with a sensor is required. In this study, blood pressure was measured using pulse transit time using Photoplethysmography. In this study, blood pressure was estimated by using systolic blood pressure. And it is possible to make measurement only with PPG itself, which can contribute to making a micro blood pressure measuring device. As a result, systolic blood pressure and PPG's S1-P and P-S2 were used to analyze the possibility of blood pressure estimation.

Recognizing Sleeping Posture on Bed by using the Measurement of Body Pressure Distribution (체압분포 측정을 이용한 수면자세 인식)

  • 권규식;김진선;박세진
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.211-219
    • /
    • 1999
  • Sleeping is important activity in bedroom and it takes one third of our lifetime. The body pressure distribution on bed has been considered as one of the most important factors affecting sleeping comfort. The measurement contact pressure has been applied to design seat, mattress, shoes, etc., for prevention of pressure sores and improvement of products. This paper discusses the recognizing rule of sleeping posture using contact pressure. Subjects' ages are ranged from twenties to fifties. They include 29 males and 35 females. Body pressure distribution is measured in the state of stable bed when subject lies on his/her back, on his/her side and on his/her face. We made recognizing rules of sleeping posture through statistical analysis; ANOVA and regression analysis, qualitative analysis.

  • PDF

Telemetry Silicon Pressure Sensor Using LC Resonance (LC 공진을 이용한 원격측정용 실리콘 압력센서)

  • Kim, Soon-Young;Pak, Jean-Sung;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2254-2256
    • /
    • 2000
  • This paper presents an implantable telemetry LC resonance-type pressure sensor for the measurement of the ventricle pressure. This sensor consists of a capacitor and an inductor. This resonant circuit is magnetically coupled with an external antenna coil. The resonance frequency of the circuit decreases as the sensor capacitance is increased by the applied pressure. The inductance and the capacitance are 428nH and 0.98${\mu}F$, respectively. The resonance frequency is 245.7MHz when the differential pressure is zero. The sensitivity of the sensor is 9.477kHz/Pa.

  • PDF

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

Estimation of Ultrasonic Energy and Sonochemical Effects in Double-Bath-Type Systems and Heterogeneous Systems (이중 반응기 조건 및 비균일계 조건에서의 초음파 에너지 및 화학적 효과 평가)

  • Lee, Hyeon Jae;Son, Younggyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.5
    • /
    • pp.40-47
    • /
    • 2017
  • The effects of ultrasound in heterogeneous system were investigated in three kinds of ultrasonic systems including a bath-type system (System #1), a double-bath-type system (System #2), and a double-bath-type system partly filled with glass beads (System #3). The ultrasound energy and its attenuation were quantified using calorimetry and the sound pressure measurement method. The sonochemical effects mainly involved in radical oxidation reactions were quantified using KI dosimetry. It was found that ultrasound energy was significantly attenuated in System #2 and #3 due to the presence of solid materials such as a submerged stainless steel reactor and glass beads. However, in spite of low ultrasound energy status, sonochemical oxidation reactions occurred more violently due to the presence of glass beads in System #3. In addition, calorimetry was more adequate to estimate the total energy status of ultrasound in sonoreactors compared to the sound pressure measurement method.

Tool Wear and Fracture Monitoring through the Sound Pressure in Turning Process (음압을 이용한 선삭작업에서의 마모, 파손 감시)

  • 이성일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.82-87
    • /
    • 1997
  • In order to make unmanned machining systems with satisfactory performances, it is necessary to incorporate appropriate condition monitoring systems in the machining workstation to provide the required intelligence of the expert. This paper deals with condition monitoring for tool wear and fracture during turning operation. Developing economic sensing and identification methods for turning processes, sound pressure measurement and digital signal processing technique are proposed. The validity of the proposed system is confirmed through the large number of cutting tests.

  • PDF

Unsteady Flow Rate Measurement Based on Distributed Parameter Pipeline Model (분포정수계 관로모델을 이용한 비정상 유량계측)

  • Kim, Do-Tae;Hong, Sung-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2008
  • The paper proposes a model-based measurement of unsteady flow rate by using distributed parameter pipeline model and the measured pressure values at two distant points along the pipeline. The distributed parameter model of hydraulic pipeline is applied with consideration of frequency dependent viscosity friction and unsteady velocity distribution at a cross section of a pipeline. By using the self-diagnostics functions of the measurement method, the validity is investigated by comparison with the measured and estimated pressure and flow rate wave forms at the halfway section on the pipeline. The results show good agreement between the estimated flow rate wave forms and theoretical those under unsteady laminar flow conditions. The method proposed here is useful in estimating unsteady flow rate through an arbitrary cross section in hydraulic pipeline and components without installing an instantaneous flowmeter.

Flow Measurement and Control by Time-Based Method

  • Chang, Young-Chul;Kim, No-Hyu;Kim, Yong-Cheol
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.115-116
    • /
    • 2002
  • This study aimed to investigate flow measurement by using a 'bucket and stop-watch' method of flow measurement. Most flow measurement systems measure pressure or other fluid properties to infer flow rate, though time is a variable which can be easily and very accurately measured. The main principle behind the method was to fill up a reservoir until a set pressure had been reached. This reservoir would then be emptied and the cycle would repeat itself. The prototype was designed to control flow rate using the method. It made use of computer control with an analogue digital converter and fast acting solenoid valves which controlled the flow into a reservoir. Reservoirs were available with internal diameter of 1mm up to 5.5mm to cope with a range of flow rate.

  • PDF