• 제목/요약/키워드: Pressure generator

검색결과 676건 처리시간 0.022초

System Analysis of a Gas Generator Cycle Rocket Engine

  • Cho, Won Kook;Kim, Chun IL
    • International Journal of Aerospace System Engineering
    • /
    • 제6권2호
    • /
    • pp.11-16
    • /
    • 2019
  • A system analysis program has been developed for a gas generator cycle liquid rocket engine of 30 ton class. Numerical models have been proposed for a combustor, a turbopump, a gas generator and pressure drop through a regenerative cooling system. Numerical algorithm has been validated by comparing with the published data of MC-1. The major source of error is not the numerical algorithm but the imperfect performance models of subsystems. So the precision of the program can be improved by revising the performance models using experimental data. The sea level specific impulse and vacuum specific impulse have been demonstrated for a 30 ton class gas generator engine. The optimal condition of combustor pressure and mixture ratio for specific impulse which is a typical characteristic of a gas generator cycle engine has been illustrated.

대형 저압 증발식 조수기 개발 (A Development Study on the Evaporation Type Large Fresh Water Generator)

  • 김병덕;송치성;김경근;김종헌;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권4호
    • /
    • pp.1-12
    • /
    • 1994
  • Most merchant ships are supplied with the only essential fresh water from a port for economical cargo transportation and the reduction of a nevigation expense. And the deficient fresh water for a voyage is produced by fresh water generator with the various exhaust energy generated in the engine room on a voyage. At present, an evaporation type fresh water generator are extensively used on ship because the operating cost of it is lower than that of a reverse osmosis pressure type. This study introduce a development results on the large evaporation type fresh water generator enable to be used for large merchant ships. It is accomplished the performance test using the developed large fresh water generator.

  • PDF

경사형 마멸 손상부를 가진 증기발생기 전열관의 파열압력 해석 (The Burst Pressure Analysis of Steam Generator Tubes with Inclined Type of Wear Damage)

  • 신규인;박재학;정명조;최영환
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.11-15
    • /
    • 2004
  • The fretting-fatigue by leaking is one of the significant degradation in steam generator tubes. In this study, the burst pressure of inclined damaged steam generator tubes were obtained from three criterions by using the finite element method. The analysis results were also compared with the experiment data from published references and they showed a good agreement with the experiment data.

A Study on Insulation Properties of Global VPI Type Generator through Replacement of Stator Windings

  • Kong, Taesik;Kim, Heedong;Lee, Sooho;Park, Jaehyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.113-117
    • /
    • 2017
  • As the competition in the manufacturing market for small and medium sized generators is intensifying, there is increasing pressure to reduce production cost. Manufacturing the generator stator windings with global vacuum pressure impregnation (GVPI) is a very effective way to reduce costs. However, the stator winding has a fatal disadvantage in that the insulation wears due to vibration in the slot. KEPRI (KEPCO Research Institute) conducted insulation diagnosis for three generators in KOMIPO (Korea Midland Power Co., Ltd.) which were manufactured by GVPI and operated for about 17 years. Insulation diagnosis showed that deterioration of insulation has progressed significantly. Therefore, KEPRI recommended replacing the stator windings of all three generators. In this paper, the insulation properties of the generator stator winding with global GVPI are described by comparing and analyzing the insulation diagnosis results and visual inspection for stator windings.

증기발생기 파울링과 전기출력의 상관성 고찰 (A Study on the Relationship between Steam Generator Fouling and the Electric Power)

  • 조남철;신동만;김용식
    • 한국압력기기공학회 논문집
    • /
    • 제13권2호
    • /
    • pp.31-37
    • /
    • 2017
  • The heat transfer function or thermal performance is the most important function of the steam generator component in nuclear power plants. The declining of thermal performance, fouling does not affect the electric power of the nuclear power plant within a certain fouling level, but it affects the output when goes beyond the governor valve wide open of the turbine. The VWO steam pressure can be predicted through the thermal performance evaluation of steam generators in the nuclear power plant. In consideration of the fouling characteristics of the steam generator, methods of the thermal performance evaluation and fouling cases are reviewed, and also the critical VWO value is estimated through the actual thermal performance evaluation. It is necessary to apply the VWO theory based on the thermal performance of the steam generators.

마멸에 의해 손상된 증기발생기 전열관의 파열압력 해석 (Analysis of Burst Pressure for Wear-Damaged Steam Generator Tubes)

  • 신규인;박재학
    • 한국안전학회지
    • /
    • 제18권4호
    • /
    • pp.16-22
    • /
    • 2003
  • Generally the rupture of steam generator tubes proceeds from significant plastic deformation before failure. In this study, the burst pressures of damaged steam generator tubes were calculated from the plastic instability analysis with the finite element method. Two wear types, flat and circumferential types were considered. An equation for the burst pressure was proposed by using the strength reduction factor and the Svensson equation. The analysis results were compared with the experiment data from published references and they showed a good agreement with the experiment data.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.

축소형 가스발생기 연소안정성 특성 (Combustion Stability Characteristics in Sub-scale Gas Generator)

  • 안규복;강동혁;김문기;임병직;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.69-72
    • /
    • 2011
  • 추력 75톤급 액체로켓엔진용 가스발생기의 초기 검증을 위한 세 번째 축소형 모델에서 연소시험이 수행되었다. 본 논문에서는 세 번째 축소형 가스발생기 모델의 연소시험 중 발생한 저주파 연소불안정에 대한 분석 결과를 기술하였다. 이러한 저주파 압력섭동은 연소실 압력, 산화제/연료 분사기의 차압과 연관된 것으로 판단된다.

  • PDF

간극효과를 고려한 증기발생기 전열관의 3차원 유한요소해석 (3-D Finite Element Analyses of Steam Generator Tubes Considering the Gap Effects)

  • 조영기;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2011
  • Steam generator is one of the main equipments that affect safety and long term operation in nuclear power plants. Fluid flows inside and outside of the steam generator tubes and induces vibration. To prevent the vibration the tubes are supported by AVB (anti vibration bar). When the steam generator tube contact to AVB, it is damaged by the accumulation of wear and corrosion. Therefore studies are required to determine the effects of the gap between the steam generator tube and AVB. In order to obtain the stress and the displacement distributions of the steam generator tube, three dimensional finite element analyses were performed by using the commercial program ANSYS. Using the calculated the stress and the displacement distributions, the static residual strength of the steam generator tube can be evaluated. The results show that the stress and displacement of the steam generator tube increase significantly compared with the results from a zero-gap model.

수압이 자흡식 마이크로버블 발생장치의 산소 용해율에 미치는 영향 (Effect of Hydraulic Pressure on Bubble Dissolution Rate of Ejector Type Microbubble Generator)

  • 김현식;임지영;박수영;김진한
    • 유기물자원화
    • /
    • 제25권2호
    • /
    • pp.27-31
    • /
    • 2017
  • 본 연구에서는 자흡식 마이크로버블 발생장치를 운전함에 있어서 수심 변화에 의한 수압이 산소 용해율에 미치는 영향에 대하여 평가하였다. 연구결과, 흡입 공기량의 경우 수압이 증가할수록 노즐 토출부에 작용하는 힘의 증가로 감소하는 경향을 나타내었다. 산소전달계수는 수심이 증가할수록 수압 증가에 의한 흡입 공기량 감소와 반응조 용적의 증가로 감소하는 경향을 나타내었으나 수심이 증가할수록 자흡식 마이크로버블 발생장치에서 발생되는 마이크로버블의 체류시간이 증가하여 산소 용해율은 증가하는 경향을 나타내었다. 그러나 자흡식 마이크로버블 발생장치 용량에 대비하여 수심이 과도하게 깊을 경우 낮은 흡입 공기량 및 산소전달계수로 인하여 산소 용해율은 감소할 것으로 판단된다. 따라서 자흡식 마이크로버블 발생장치 운전 시 수압이 중요한 고려사항이 됨을 확인할 수 있었다.