• 제목/요약/키워드: Pressure drops

검색결과 300건 처리시간 0.031초

오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 압력강하에 관한 실험적 연구 (Study on Evaporation Pressure Drop of R- l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger)

  • 박재홍;김영수
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.855-862
    • /
    • 2004
  • This study reports pressure drops during evaporation for R-l34a, R-407C (a mixture of 23 wt% R-32, 25 wt% R-125, and 52 wt% R-l34A) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) in the oblong shell and Plate heat exchanger. The effects of the mass fluxes, heat fluxes, refrigerant saturation temperatures and vapor quality of refrigerants on the measured data were explored in detail. The present data showed that pressure drops of all refrigerants increase with the vapor quality. At a higher mass flux, pressure drops are higher for the entire range of the vapor quality A rise in the heat flux doesn't show significant effects on the pressure drops. Finally, at a higher saturation temperature the pressure drops are found to be lower. The pressure drops for R-407C were approximately 20% lower than those of R-l34a. R-410A had 33% lower pressure drops than R-l34a. Correlation is also provided for the measured pressure drops in terms of the friction factor.

Effect of Bundle Junction Face and Misalignment on the Pressure Drops Across a Randomly Loaded and Aligned 12 Bundles in Candu Fuel Channel

  • H. C. Suk;K. S. Sim;C. H. Chung;Lee, Y. O.
    • Nuclear Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.280-289
    • /
    • 1996
  • The pressure drop of twelve fuel bundle string in the CANDU-6 fuel channel is equal to the sum of the eleven junction pressure losses, the bundle string entrance and exit pressure losses, the skin friction pressure loss, and other appendage pressure losses, where the junction loss is dependent on the bundle end faces and angular alignments of the junctions. The results of the single junction pressure drop tests in a short rig show that the most probable pressure drop of the eleven junctions was analytically equal to the eleven times of average pressure drop of all the possible single junction pressure drops, and also that the largest and smallest junction pressure drops across the eleven junctions probably occurred only with BA and BB type junctions, respectively, where A and B denote the bundle end sides with an end-plates on which a company monogram is stamped and unstamped, respectively.

  • PDF

테이프와 거칠기가 설치된 사각 채널의 압력강하 특성 (Characteristics of Pressure Drops in Square Channels with Twisted Tape Inserts plus Axial Interrupted Ribs)

  • 안수환;배성택;강호근
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.38-42
    • /
    • 2006
  • Pressure drops and friction factors in square channels with twisted tape inserts plus axial interrupted ribs are investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, $e/D_h$, is kept at 0.057 and test section length-to-hydraulic diameter, $L/D_h$ is 30. The pressure drops and friction factor values are enhanced with axial interrupted ribs and twisted tape inserts. Square channels with twisted tape inserts plus axial interrupted ribs show the greatest pressure loss penalty in the present work. Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

시판되고 있는 유사마스크 제품의 여과효율성능 비교평가 (Evaluation of Filtration Performance Efficiency of Commercial Cloth Masks)

  • 장지영;김승원
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.203-215
    • /
    • 2015
  • Objectives: This study was designed to evaluate the filtration efficiencies and pressure drops of five commercial cloth masks (4 plate type, 1 cup type) in comparison to the performance of a class 1 disposable respirator (reference respirator). A further objective was to evaluate the effects of the number of layers and wash treatment independently on filtration efficiencies and pressure drops. Methods: Polydisperse NaCl aerosols were generated in an aerosol chamber and their concentrations were measured by an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$ (five channels). Results: The filtration efficiencies of the five cloth masks and the reference respirator were D: 9.5%, C: 18.5%, E: 23.6%, A: 28.5%, B: 29.7% and R: 91.1%, respectively, and the pressure drops through them were C, D: 0.8 Pa, E: 1.7 Pa, B: 6.4 Pa, A: 42.7 Pa and R: 19.3 Pa, respectively. The filtration efficiencies of the cloth masks and reference respirator were below the class 1 respirator criterion (${\geq}94.0%$) of the Ministry of Employment and Labor (MOEL) and Ministry of Food and Drug Safety (MFDS). The pressure drops satisfied the class 1 respirator criterion (${\leq}70Pa$) of MOEL and MFDS. When the cloth masks were folded into two and four layers, the filtration efficiencies of cloth masks A, B, C, D (plate type) increased 1.7-4.6 times, and 2.3-6.8 times, respectively, compared to the efficiencies of the same products in a single layer. Pressure drops increased as the number of layers was increased. The filtration efficiency of cloth mask E with a liner was 1.3 times higher than that of the same mask without a liner, and the pressure drop was lower in the no-liner configuration. After a single washing, the filtration efficiencies of all the cloth mask products decreased 1.04-4.0 times compared to those of the same products intact. For the cloth masks C and E, their filtration efficiencies were significantly decreased after washing (p<0.05). The pressure drops of all cloth masks were 1.2-2.0 times lower after washing. Conclusions: The filtration efficiencies of the five cloth masks were below 30% and did not improve greatly by increasing the number of layers. After a single washing, their performances decreased. Considering the above and other issues identified with cloth masks, such as poor fit and stretched fibers through use, people should not expect protection against particulate matters from the cloth masks on the market.

오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 응축성능에 관한 실험적 연구 (Study on R-l34a, R-407C, and R-410A Condensation Performance in the Oblong Shell and Plate Heat Exchanger)

  • 박재홍;김영수
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1535-1548
    • /
    • 2004
  • Condensation heat transfer experiments were conducted with the oblong shell and plate heat exchanger without oil in a refrigerant loop using R-l34a, R-407C and R-410A. An experimental refrigerant loop has been developed to measure the condensation heat transfer coefficient h$_{r}$ and frictional pressure drop $\Delta$p$_{f}$ of the various refrigerants in a vertical oblong shell and plate heat exchanger. The effects of the refrigerant mass flux(40∼80kg/$m^2$s), average heat flux(4∼8kW/$m^2$), refrigerant saturation temperature(30∼4$0^{\circ}C$) and vapor quality of refrigerants on the measured data were explored in detail. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. A comparison of the performance of the various refrigerants revealed that R-410A had the highest heat transfer performance followed by R-l34a, and R-407C had the lowest performance of the refrigerants tested. The pressure drops were also reported in this paper. The pressure drops for R-410A were approximately 45% lower than those of R-l34a. R-407C had 30% lower pressure drops than R-l34a. Experimental results were compared with several correlations which predicted condensation heat transfer coefficients and frictional pressure drops. Comparison with the experimental data showed that the previously proposed correlations gave unsatisfactory results. Based on the present data, empirical correlations of the condensation heat transfer coefficient and the friction factor were proposed.tor were proposed.sed.

An experimental study on two-phase flow resistances and interfacial drag in packed porous beds

  • Li, Liangxing;Wang, Kailin;Zhang, Shuangbao;Lei, Xianliang
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.842-848
    • /
    • 2018
  • Motivated by reducing the uncertainties in quantification of debris bed coolability, this paper reports an experimental study on two-phase flow resistances and interfacial drag in packed porous beds. The experiments are performed on the DEBECO-LT (DEbris BEd COolability-Low Temperature) test facility which is constructed to investigate the adiabatic single and two phase flow in porous beds. The pressure drops are measured when air-water two phase flow passes through the porous beds packed with different size particles, and the effects of interfacial drag are studied especially. The results show that, for two phase flow through the beds packed with small size particles such as 1.5 mm and 2 mm spheres, the contribution of interfacial drag to the pressure drops is weak and ignorable, while the significant effects are conducted on the pressure drops of the beds with bigger size particles like 3 mm and 6 mm spheres, where the interfacial drag in beds with larger particles will result in a descent-ascent tendency in the pressure drop curves along with the fluid velocity, and the effect of interfacial drag should be considered in the debris coolability analysis models for beds with bigger size particles.

배수관망내 수압부족시 절점수요량의 변화에 대한 기초적 고찰 (A Basic Study for the Variation of Nodal Demands According to the Low Pressure in Water Distribution Systems)

  • 현인환;이상목;김영환;안용호
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.726-732
    • /
    • 2002
  • Pressure drop could happen in the water distribution systems due to pipe breaks or maintenance. The pressure drop causes the water service shutdown and nodal water demands should be reduced in some areas. The conventional analysis method of water distribution systems can not consider the change of nodal water demands caused by these pressure drops. This study is to investigate the variation of nodal water demands according to the nodal water pressure and its effect on the analysis of water distribution systems. For these purpose, one real water service district was selected as a study area. As a result, nodal water demand patterns according to the water pressure could be suggested. Also, we could confirm that the suggested new analysis method for the water distribution systems which considering water pressure drops could be more reliable than the conventional method.

Parametric study of porous media as substitutes for flow-diverter stent

  • Ohta, Makoto;Anzai, Hitomi;Miura, Yukihisa;Nakayama, Toshio
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제2권2호
    • /
    • pp.111-125
    • /
    • 2015
  • For engineers, generating a mesh in porous media (PMs) sometimes represents a smaller computational load than generating realistic stent geometries with computer fluid dynamics (CFD). For this reason, PMs have recently become attractive to mimic flow-diverter stents (FDs), which are used to treat intracranial aneurysms. PMs function by introducing a hydraulic resistance using Darcy's law; therefore, the pressure drop may be computed by test sections parallel and perpendicular to the main flow direction. However, in previous studies, the pressure drop parallel to the flow may have depended on the width of the gap between the stent and the wall of the test section. Furthermore, the influence of parameters such as the test section geometry and the distance over which the pressure drops was not clear. Given these problems, computing the pressure drop parallel to the flow becomes extremely difficult. The aim of the present study is to resolve this lack of information for stent modeling using PM and to compute the pressure drop using several methods to estimate the influence of the relevant parameters. To determine the pressure drop as a function of distance, an FD was placed parallel and perpendicular to the flow in test sections with rectangular geometries. The inclined angle method was employed to extrapolate the flow patterns in the parallel direction. A similar approach was applied with a cylindrical geometry to estimate loss due to pipe friction. Additionally, the pressure drops were computed by using CFD. To determine if the balance of pressure drops (parallel vs perpendicular) affects flow patterns, we calculated the flow patterns for an ideal aneurysm using PMs with various ratios of parallel pressure drop to perpendicular pressure drop. The results show that pressure drop in the parallel direction depends on test section. The PM thickness and the ratio of parallel permeability to perpendicular permeability affect the flow pattern in an ideal aneurysm. Based on the permeability ratio and the flow patterns, the pressure drop in the parallel direction can be determined.

다공성소결윅구조에 따른 루프 히트파이프에서 압력손실의 이론적 분석 (Theoretical Analysis of the Pressure Drop in Loop Heat Pipe by Sintered Porous Wick Structure)

  • 이기우;이욱현;박기호;이계중;전원표;인현만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1225-1230
    • /
    • 2004
  • In this paper, the pressure drops were investigated according to the sintered porous wick structure in loop heat pipe(LHP) by theoretical analysis. LHP has the wick only in evaporator for the circulation of working fluid, so utilizes porous wick structure which pore diameter is very small for large capillary force. This paper investigates the effects of different parameters on the pressure drops of the LHP such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity. Working fluid is water and the material of sintered porous wick is copper. According to the these different parameters, capillary pressure, pressure drop in wick were analized by theoretical design method of LHP.

  • PDF

안쪽축이 회전하는 환형관내 헬리컬 유동장의 실험적 연구 (Experimental Study on the Helical Flow Field in a Concentric Annulus with Rotating Inner Cylinders)

  • 황영규;김영주
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.822-833
    • /
    • 2000
  • This experimental study concerns the characteristics of a transitional flow in a concentric annulus with a diameter ratio of 0.52, whose outer cylinder is stationary and inner one rotating. The pressure drops and skin-friction coefficients have been measured for the fully developed flow of water and that of glycerine-water solution (44%) at a inner cylinder rotational speed of $0{\sim}600$ rpm, respectively. The transitional flow has been examined by the measurement of pressure drops and the visualization of flow field, to reveal the relation of the Reynolds and Rossby numbers with the skin-friction coefficients and to understand the flow instability mechanism. The present results show that the skin-friction coefficients have the significant relation with the Rossby numbers, only for laminar regime. The occurrence of transition has been checked by the gradient changes of pressure drops and skin-friction coefficients with respect to the Reynolds numbers. The increasing rate of skin-friction coefficient due to the rotation is uniform for laminar flow regime, whereas it is suddenly reduced for transitional flow regime and, then, it is gradually declined for turbulent flow regime. Consequently, the critical (axial-flow) Reynolds number decreases as the rotational speed increases. Thus, the rotation of inner cylinder promotes the early occurrence of transition due to the excitation of taylor vortices.