• 제목/요약/키워드: Pressure drainage

검색결과 307건 처리시간 0.025초

Gravel Pile에 의한 연약지반 개량 시험시공 사례연구 (A Case Study on the Application of Gravel Pile in Soft Ground)

  • 천병식;고용일;여유현;김백영;최현석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.223-230
    • /
    • 2000
  • Sand drain as a vertical drainage is widely used in soft ground improvement. Recently, sand, the principal source of sand drain, is running out. The in-situ tests were carried out to utilize gravel as a substitute for sand. In-situ tests area was divided into two areas by material used. One is Sand Drain(SD) and Sand Compaction Pile(SCP) area, the other is Gravel Drain(GD) and Gravel Compaction Pile(GCP) area. Both areas were monitored to obtain the information on settlement, pore water pressure and bearing capacity by measuring instruments for stage loading caused by embankment. The results of measurements were analyzed, The clogging effect was checked at various depth in gravel column after the test. According to the test results, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. It is assumed that gravel is relatively acceptable as a drainage material. Gravel is considered to be a better material than sand for bearing capacity, and it is found that bearing capacity is larger when gravel is used as a gravel compaction pile than as a gravel drain.

  • PDF

Slowly Recovering Isolated Bilateral Abducens Nerve Palsy after Embolization of Ruptured Anterior Communicating Artery Aneurysm

  • Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Chung, Young Seob
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권2호
    • /
    • pp.112-114
    • /
    • 2013
  • Bilateral abducens nerve palsy related to ruptured aneurysm of the anterior communicating artery (ACoA) has only been reported in four patients. Three cases were treated by surgical clipping. No report has described the clinical course of the isolated bilateral abducens nerve palsy following ruptured ACoA aneurysm obliterated with coil. A 32-year-old man was transferred to our institution after three days of diplopia, dizziness and headache after the onset of a 5-minute generalized tonic-clonic seizure. Computed tomographic angiography revealed an aneurysm of the ACoA. Magnetic resonance imaging showed focal intraventricular hemorrhage without brain stem abnormalities including infarction or space-occupying lesion. Endovascular coil embolization was conducted to obliterate an aneurysmal sac followed by lumbar cerebrospinal fluid (CSF) drainage. Bilateral paresis of abducens nerve completely recovered 9 weeks after ictus. In conclusion, isolated bilateral abducens nerve palsy associated with ruptured ACoA aneurysm may be resolved successfully by coil embolization and lumbar CSF drainage without directly relieving cerebrospinal fluid pressure by opening Lillequist's membrane and prepontine cistern.

HYSTERETIC MODELING ON THE CONVECTIVE TRANSPORT OF ORGANIC SOLVENT IN AN UNSATURATED SOIL ZONE

  • Lee, Kun-Sang
    • Environmental Engineering Research
    • /
    • 제11권5호
    • /
    • pp.241-249
    • /
    • 2006
  • A mathematical model is described for the prediction of convective upward transport of an organic solvent driven by evaporation at the surface, which is known as the major transport mechanism in the in-situ photolysis of a soil contaminated with 2,3,7,8-tetrachlorodibenzo-p-dioxin(TCDD). A finite-element model was proposed to incorporate the effects of multiphase flow on the distribution of each fluid, gravity as a driving force, and the use of hysteretic models for more accurate description of k-S-p relations. Extensive numerical calculations were performed to study fluid flow through three types of soils under different water table conditions. Predictions of relative permeability-saturation-pressure (k-S-p) relations and fluids distribution for an illustrative soil indicate that hysteresis effects may be quite substantial. This result emphasizes the need to use hysteretic models in performing flow simulations including reversals of flow paths. Results of additional calculations accounting for hysteresis on the one-dimensional unsaturated soil columns show that gravity affects significantly on the flow of each fluid during gravity drainage, solvent injection, and evaporation, especially for highly permeable soils. The rate and duration of solvent injection also have a profound influence on the fluid saturation profile and the amount of evaporated solvent. Key factors influencing water drainage and solvent evaporation in soils also include hydraulic conductivity and water table configuration.

현장 강우재현시험을 통한 방조제 사면필터층의 필터성능분석 (Evaluation of Filter Capacity for Sea Dyke Slope Filter Layer by In-situ Rainfall Test)

  • 오영인;김서룡;유전용;김현태
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.828-837
    • /
    • 2006
  • Geotextiles consist of three major types of geosynthetic material (woven, non-woven and composite) and the functions of geotextiles are separation, reinforcement, filtration, drainage and as a moisture barrier. Although the many research scholar and engineer developed and established the design criteria and construction methodology, sustainable research still needed for optimum design methodology to the complicate field conditions. In this study, in-situ rainfall test performed to develop suitable filter system for sea dyke upper slope filter layer. In-situ rainfall test conducted for seven different filter system and measured the infiltration flux and pore pressure at various filter layer. Based on the test results, the double layered geotextile filter and sand transition system is most suitable for sea dyke upper filter layer because which system is effective for drainage of infiltration flow and minimize the deformation of sea dyke cover stone.

  • PDF

Usefulness of an Additional Mattress Suture for the Extracranial Drainage Catheter

  • Eom, Dong Woong;Kim, Jung Soo;Jeon, Kyoung Dong;Kim, Hoon;Choi, Byeong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권5호
    • /
    • pp.444-447
    • /
    • 2013
  • In most intracranial surgery cases, a drain catheter is inserted to prevent the collection of the wound hematoma or seroma. A drain catheter is also inserted to drain the hematoma or the cerebrospinal fluid. The drain catheter itself does not cause complications; but many complications occur during its removal, such as hematoma, seroma, air collection and pseudomeningocele formation. To prevent these complications, neurosurgeons perform a suture on the catheter to remove the site. In this study, an additional horizontal mattress suture and an anchoring suture to the drainage catheter are proposed. This method maintains negative pressure in the catheter insertion site during the catheter removal, compresses the catheter tunnel site and attaches the external wounds strongly. The technique is easy and safe to perform, and does not require an additional suture to remove the catheter.

Extensive Tension Pneumocephalus Caused by Spinal Tapping in a Patient with Basal Skull Fracture and Pneumothorax

  • Lee, Seung-Hwan;Koh, Jun-Seok;Bang, Jae-Seung;Kim, Myung-Chun
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권5호
    • /
    • pp.318-321
    • /
    • 2009
  • Tension pneumocephalus may follow a cerebrospinal fluid(CSF) leak communicating with extensive extradural air. However, it rarely occurs after diagnostic lumbar puncture, and its treatment and pathophysiology are uncertain. Tension pneumocephalus can develop even after diagnostic lumbar puncture in a special condition. This extremely rare condition and underlying pathophysiology will be presented and discussed. The authors report the case of a 44-year-old man with a basal skull fracture accompanied by pneumothorax necessitating chest tube suction drainage, who underwent an uneventful lumbar tapping that was complicated by postprocedural tension pneumocephalus resulting in an altered mental status. The patient was managed by burr hole trephination and saline infusion following chest tube disengagement. He recovered well with no neurologic deficits after the operation, and a follow-up computed tomography (CT) scan demonstrated that the pneumocephalus had completely resolved. Tension pneumocephalus is a rare but serious complication of lumbar puncture in patients with basal skull fractures accompanied by pneumothorax, which requires continuous chest tube drainage. Thus, when there is a need for lumbar tapping in these patients, it should be performed after the negative pressure is disengaged.

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

Suction 연직배수 공법과 PDB 공법의 변위거동 차이에 대한 유한 요소 해석 (Finite element analysis for the difference of displacement behavior developed from suction drain method and vertical drain method)

  • 김기년;안동욱;한상재;정승용;김수삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1165-1172
    • /
    • 2006
  • In this study, an aspect of settlement, developed from different ground improvement method like suction drain method using vacuum pressure and vertical drain method using overburden pressure, was compared each other. In order to analyze settlement tendency of each method exactly, the finite element analysis program was used. The analyses of vertical settlement and lateral displacement for suction drain method and vertical drain method were conducted independently during the solving stage. The initial condition of drainage zone was fixed with 25m depth and 21m width. After the program analyses, the settlement condition had a different tendency with the ground improvement method. Especially, in the results of vertical drain method, the disparity of settlement between the middle of improved zone and unimproved zone. In the case of suction drain method, however, the difference of settlement was smaller than that of vertical drain method.

  • PDF

NATM 터널의 응력-간극수압 연계 유한요소모델링 (Stress-Pore Pressure Coupled Finite Element Modeling of NATM Tunneling)

  • 유충식;김선빈
    • 한국지반공학회논문집
    • /
    • 제22권10호
    • /
    • pp.5-20
    • /
    • 2006
  • 본 논문에서는 지하수위 하에서 터널이 시공되는 조건을 대상으로 응력-간극수압 연계 유한요소해석 수행시 모델링 측면에서 중요하게 다뤄져야 하는 내용을 고찰하였다. 먼저 연계해석 수행시 요구되는 지하수위 저하와 지반거동과의 관계에 대한 배경 이론을 알아보았으며, 이를 토대로 모델링 측면에서 해석결과에 영향을 미칠 수 있는 다양한 인자들을 선정하고, 선정된 영향인자에 대한 매개변수 연구를 수행하였다. 지하수위 저하가 동반되는 터널 시공조건에서의 유한요소석 모델링 결과는 지반의 불포화특성 고려여부가 가장 큰 영향을 미치는 것으로 나타났으며 본 고에서는 결과를 종합하여 연계해석 모델링시 중요하게 검토되어야 고려사항을 제시하였다.

Free-strain solutions for two-dimensional consolidation with sand blankets under multi-ramp loading

  • Zan Li;Songyu Liu;Cuiwei Fu
    • Geomechanics and Engineering
    • /
    • 제35권4호
    • /
    • pp.385-393
    • /
    • 2023
  • To analyze the consolidation with horizontal sand drains, the plane strain consolidation model under multi-ramp loading is established, and its corresponding analytical solution is derived by using the separation of variables method. The proposed solution is verified by the field measurement data and finite element results. Then, the effects of the loading mode and stress distribution on consolidation and dissipation of pore pressure are investigated. At the same time, the influence of hydraulic conductivity and thickness of sand blankets on soil consolidation are also analyzed. The results show that the loading mode has a significant effect on both the soil consolidation rate and generation-dissipation process of pore water pressure. In contrast, the influence of stress distribution on pore pressure dissipation is obvious, while its influence on soil consolidation rate is negligible. To guarantee the fully drained condition of the sand blanket, the ratio of hydraulic conductivity of the sand blanket to that of clay layer kd/kv should range from 1.0×104 to 1.0×106 with soil width varying from 100 m to 1000 m. A larger soil width correspondingly needs a greater value of kd/kv to make sure that the pore water can flow through the sand blanket smoothly with little resistance. When the soil width is relatively small (e.g., less than 100 m), the effect of thickness of the sand blanket on soil consolidation is insignificant. And its influence appears obvious gradually with the increase of the soil width.