Design of a New Flexible In-pipe Inspection Robot (새로운 구조의 유연한 배관탐사 로봇 설계)

  • Choi, Hyeung-Sik;Kim, Dong-Ho;Kim, Dong-Hyun;Lee, Jong-Hoon;Whang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.175-183
    • /
    • 2008
  • In this paper, a new in-pipe inspection robot was developed for inspecting a large number of circular pipe insides of the sea plant, ships, and buildings. A new pressure generation system was devised to inspect circular pipes with different diameters and to move up and down slant or perpendicular slopes inside of the pipe. Also, a design method was analyzed to decide the capacity of driving motor for the robot if the mass and maximum velocity of the robot are identified. According to the design specification, a robot was developed and was tested to verify the performance of the pressure generation system. For tests, a control system was developed.

NUMERICAL ANALYSIS OF NON-EQUILIBRIUM HYDRATE PELLET DECOMPOSITION (하이드레이트 펠릿의 비평형 분해과정 수치해석)

  • Kang, Jung-Ho;Nam, Jin-Hyun;Kim, Charn-Jung;Song, Myung-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.268-275
    • /
    • 2008
  • The prediction of hydrate pellet decomposition characteristics is required to design the regasification process of GTS (gas to solid) technology, which is considered as an economic alternative for LNG technology to transport natural gas produced from small and stranded gas wells. Mathematical model based on the conservation principles, the phase equilibrium relation, equation of gas state and phase change kinetics was set up and numerical solution procedure employing volume averaged fixed grid formulation and extended enthalpy method are implemented. Initially, porous methane hydrate pellet is at uniform temperature and pressure within hydrate stable region. The pressure starts to decrease with a fixed rate down to the final pressure and is kept constant afterwards while the bounding surface of pellet is heated by convection. The predicted convective heat and mass transfer accompanied by the decomposed gas flow through hydrate/ice solid matrix is reported focused on the comparison of spherical and cylindrical pellets having the same effective radius.

  • PDF

Aerodynamic Characteristics on Railway Acoustic Screen Using 1/61-scaled Mock-Up (모형시험장치를 이용한 철도 선로변 방음벽에 미치는 공력 특성시험)

  • Jang, Yong-Jun;Kim, Dong-Hyeon;Park, Won-Hee;Park, Seung-Yil
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.430-437
    • /
    • 2007
  • The experiments for aerodynamic characteristics on railway acoustic screen are performed using 1/61 scale-down mock-up facility. The train model for the experiment is high speed train (KTX) and the tested speed is about 300km/h. The tested train length is about 61cm which is corresponding to two units of train. The strength of pressure wave is measured using piezo typed pressure sensor. The measured pressure is compared with field test data and UIC 779-1 values.

  • PDF

The Effects of Pressure, Wind Velocity, and Diameter of Wet Element on the Measurement of Relative Humidity by a Psychrometer (압력, 풍속 및 습구온도계의 크기가 건습구습도계를 이용한 상대습도 측정에 미치는 영향)

  • Chi, D.S.;Kim, S.T.;Park, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.2
    • /
    • pp.137-141
    • /
    • 1990
  • When the relative humidity is measured with an aspirated psychrometer, three factors, which affect the measurement of relative humidity, are atmospheric pressure, the size of wet element and the wind velocity. This paper investigated the effects of the above three factors, and the computer code was developed in order to enhance the accuracy of the relative humidity measurement. As results, it is found that the relative humidity decreases by 6%RH with increasing atmospheric pressure from 650 mbar to 1100 mbar. It is found that the relative humidity drops down when the size of the wet element increases, though the effect of the size of the wet element is not significant. Finally, relative humidity increases with the increasing wind velocity. The difference between the psychrometic table in the present KS and the present results is about 2%RH maximum. As a conclusion, the three factors mentioned above should be considered in order to secure accurate measurement of relative humidity.

  • PDF

On the Characteristics of the SO$_2$ Concentration Variation in Pusan, Korea (부산 지역의 SO$_2$ 농도 변화 특성에 관한 고찰)

  • 전병일;김유근;이화운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.245-251
    • /
    • 1994
  • We considered that characteristics of SO$_2$, concentration level and relations of the meteorological parameters and high pollution concentration from the data measured 7 air quality continuous monitoring stations during 4 years, from 1990 to 1993 in Pusan. The SO$_2$ concentration level showed decreasing trend yearly, it was maximum in Winter, minimum in Summer. The time of SO$_2$ peak concentration lagged from seashore to land because of break-down of the nocturnal inversion layer and seabreeze. Ihe correlations of daily SO$_2$, value between various air quality continuous monitoring stations were highest between Beomcheondong and Meongryundong, lowest between Daeyeondong and Sinpyeongdong because of difference of air Pollution emission sources characteristic. The meteorological parameters affecting SO$_2$ concentration level were minimum temperature, relative humidity, wind speed and air pressure. The SO$_2$ high pollution($\geq$95ppb) occurred almost in Winter, particulaly in such day showing lower wind speed and higher air pressure. Elementary SO$_2$ high Pollution Predictor were high pressure system and stability of lower atmosphere.

  • PDF

Development of an In-Pipe Inspection and Cleaning Robot (배관 검사 및 청소 로봇의 개발)

  • Choi, Hyeung-Sik;Na, Won-Hyun;Kang, Dong-Wan;Kang, Hyung-Suk;Jeon, Ji-Gwang;Kim, Hyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.662-671
    • /
    • 2009
  • In this paper, a robot was developed for in-pipe cleaning and inspecting a large number of circular in-pipes of sea plants, ships, and buildings. A pressure generation mechanism was devised to inspect circular in-pipes with different diameters and to move up and down slant or perpendicular slopes in-pipes. For inspection of the dark inner side of the pipe, a light system using LED which dissipats small electricity was developed. Also, a design method was analyzed to decide the capacity of driving motor for the robot when the mass and maximum velocity of the robot are identified. The robot developed based on the design specification, was tested to verify the performance of the pressure generation mechanism. In addition, a control system was developed for the test.

Characteristics of Cooling Down in the Enclosed Vacuum Tank by Water Driving Ejector (수 이젝터를 이용한 밀폐형 진공탱크내의 온도저감 특성)

  • Kim, Se-Hyun;Shin, You-Sik;Bae, Kang-Youl;Lee, Youn-Whan;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.700-705
    • /
    • 2003
  • The general cooling tower is a device for making a cooling water in refrigerant condensers or industrial process heat exchangers. The present cooling tower have defects with noises, complicated structure and environmental problems. In this paper, we constituted a new water cooling system by using a evaporating latent heat in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driving ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows in the ejector. Based on the vacuum pressure by water driving ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF

Surgical Treatment of Renovascular Hypertension Due to Primary Arteritis (원발성 동맥염에 의한 신혈관성 고혈압의 외과적 치료 :1례 보고)

  • 김주이
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.175-178
    • /
    • 1981
  • Since the first report by Freeman of renal artery repair for renovascular hypertension in 1954, there has been a gradual improvement in the results of renovascular reconstruction. This is case report of renovascular hypertension due to diffuse primary arteritis, which was performed aorto-bllateral renal bypass graft with using of Y -woven dacron graft. This 33 y-o male has complained intermittent headache, facial edema & malignent hypertension symptoms for 1.5 years. He had the history of Rt. B-K amputation due to unhealed wound after trauma of the Rt. great toe about 7 years ago. The abdominal aortography revealed nearly not visualized the Rt. renal artery & severe narrowing of the Lt. renal arterly. During postop. course, Blood pressure was well controlled. At postop. 3rd week, systolic pressure was down to 130-140mmHg But, diastolic pressure was remained to 100-110mmHg. At postop. 30th day, exploration was done due to intestinal obstruction signs. But severe ischemic enteritis was occured due to fibrotic obstruction of the superior mesenteric artery. The next day, he was dead. in spite of Rt. common iliac artery-sup. mesenteric artery bypass graft.

  • PDF

A Study on the Relief of Shell Wall Thinning around the Extraction Nozzle of Low Pressure Feedwater Heater (저압 급수가열기 추기노즐 주변 동체의 감육 완화에 관한 연구)

  • Seo, Hyuk-Ki;Park, Sang-Hun;Kim, Hyung-Jun;Kim, Kyung-Hoon;Hwang, Kyeong-Mo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2631-2636
    • /
    • 2008
  • The most components and piping of the secondary side of domestic nuclear power plants were manufactured carbon-steel and low-alloy steel. Flow accelerated corrosion leads to wall thinning (metal loss) of carbon steel components and piping exposed to the flowing water or wet steam of high temperature, pressure, and velocity. The feedwater heaters of many nuclear power plants have recently experienced sever wall thinning damage, which increases as operating time progress. Several nuclear power plants in Korea have also experienced wall thinning damage in the shell wall around the impingement baffle. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the experimental results based on down-scaled experimental facility. The experiments were performed based on several types of impingement baffle plates which are installed in low pressure feedwater heater.

  • PDF

Pulsed DB/AB T-Burner Test for Measurement of Combustion Response Function of Solid Propellants

  • Lim, Jih-Wan;Yoon, Woong-Sup;Yoo, Ji-Chang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.431-436
    • /
    • 2008
  • T-burner tests of an Al/HTPB propellant in conjunction with a Pulsed DB/AB Method were conducted to find an acoustic amplification factor. Aluminum-free and aluminum-heavy propellants were examined. Instant surface ignition was successfully made by the use of a supplementary propellant of fractionally higher reaction rate. With the presence of higher aluminum concentration in the propellants, the pressure perturbations were promptly damped down and the pressure fluctuations were no longer dispersive. Addition of aluminum particles into the propellant was advantageous for stabilizing pressure-coupled unstable waves.