• 제목/요약/키워드: Pressure down

검색결과 790건 처리시간 0.027초

체위변화에 수반되는 심맥관계반응에 관한연구 (A Study of Circulatory Responses to Postural Changes)

  • 서석완;채의업
    • The Korean Journal of Physiology
    • /
    • 제5권2호
    • /
    • pp.71-78
    • /
    • 1971
  • Anesthetized dogs were tilted from horizontal to the upright and head down position. Tilting to the upright position was followed by an increase in heart rate. In the head down position a decreased heart rate was obtained. The arterial blood pressure was decreased in the upright position and was decreased markedly in the head down position. The central venous pressure was decreased in the upright position and was markedly decreased down to the negative pressure in the head down position. The respiratory rate was slightly increased in the upright position comparing to that in the horizontal position. No remarkable changes were noted in the head down position. From the above results the following factors were discussed The decreased arterial blood pressure during the upright position was supposed to be the secondary effect from the diminished venous return that was suggested by the decreased central venous pressure. The decreased arterial blood pressure in the head down position was also supposed as the above reason as the diminished central venous pressure during the tilt. In addition the cardioinhibitory effects originated from the baroreceptors might have been operated during head down tilting. In the heart rate there was slight tachycardia in the upright position this was assumed as the abolished cardioinhibitory impulses from the baroreceptor in the upright position. On the contrary, despite of the decrease of arterial blood pressure in the head down position as well as in the upright, the bradycardia have been appeared. This was suggestive of cardioinhibitory impulses from the baroreceptors which was stretched during head down tilting. From the above findings there is a possibility of continous cardioinhibitory responses during head down tilting for this kind of the short period of 10 minutes which was chosed in this study.

  • PDF

토압 영향을 받는 Down-Up 지하공사 공법의 오픈 구간 균열 저감 방안 연구 (A Study on Crack Reduction Method in open Section of Down-Up Underground Construction Method Affected by Earth Pressure)

  • 심학보;전현수;석원균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.196-197
    • /
    • 2021
  • The underground method can be divided into Top-Down, Semi-Top-Down, Up-Up and Down-Up methods according to the construction order of the upper and lower structures. Among them, the Down-Up method proceeds with the construction of the first floor and its lower floors, and when the foundation is completed, the vertical members of the basement are sequentially completed from the foundation and the above-ground floor is constructed. In this paper, the crack reduction method around the open section of the Down-Up method affected by earth pressure was analyzed and divided into design and construction parts.

  • PDF

지하 유류비축기지 수벽공의 효율에 관한 현장계측 및 수치 해석 연구 (Field Measurements and Numerical Analysis on the Efficiency of Water Curtain Boreholes in Underground Oil Storages)

  • 이경주;이희근
    • 터널과지하공간
    • /
    • 제8권2호
    • /
    • pp.79-86
    • /
    • 1998
  • This study was performed to suggest to suggest suitable design conditions of water curtain system through analysis on pressure down in boreholes by hydraulic tests carried out I construction fields for underground oil storages. The influence by hydraulic conductivities of rock mass around boreholes on pressure down in boreholes was analysed. The relationship between array of boreholes and their pressure down was also analysed. Groundwater flow analysis on crude oil and LPG storages was carried out to evaluate results of field tests and to investigate distribution of hydraulic gradient in rock mass around cavern using finite difference method. As the results, hydraulic tests showed that pressure down in boreholes was inverse proportional to the hydraulic conductivity of surrounding rock mass. The rate of pressure down of boreholes was not influenced by water curtain system more than 20m over cavern and was proportional to installation interval of boreholes. The hydraulic gradient in rock mass around cavern was proportional to distance and interval of boreholes and its value was not satisfactory to oil tightness condition in case of no water curtain system.

  • PDF

압력조절밸브와 배관 특성을 포함한 유도무기용 기체 블로우다운 시스템의 공압부 모델링에 관한 연구 (A Study on Modeling of the Pneumatic Part in a Gas Blow-Down System Including Pressure Regulator and Pipe-Line Characteristics)

  • 박영우
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권3호
    • /
    • pp.32-39
    • /
    • 2017
  • In this study, a mathematical model of the pneumatic part in a gas blow-down system is proposed. The mathematical model consists of four major parts: pressure vessel, reservoir, pressure regulator and pipe-line. To ensure accuracy in long-time simulations, heat transfer between gas and pressure vessel is considered. The model is validated by comparing simulation results with experimental data. Experiments are conducted on the ground, where free convection can be assumed. Simulation results indicate the proposed model can accurately describe behavior of a gas blow-down system. Therefore, it may be used for design and analysis of similar systems with a slight modification.

Probabilistic Fracture Mechanics Analysis of Boling Water Reactor Vessel for Cool-Down and Low Temperature Over-Pressurization Transients

  • Park, Jeong Soon;Choi, Young Hwan;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.545-553
    • /
    • 2016
  • The failure probabilities of the reactor pressure vessel (RPV) for low temperature over-pressurization (LTOP) and cool-down transients are calculated in this study. For the cool-down transient, a pressure-temperature limit curve is generated in accordance with Section XI, Appendix G of the American Society of Mechanical Engineers (ASME) code, from which safety margin factors are deliberately removed for the probabilistic fracture mechanics analysis. Then, sensitivity analyses are conducted to understand the effects of some input parameters. For the LTOP transient, the failure of the RPV mostly occurs during the period of the abrupt pressure rise. For the cool-down transient, the decrease of the fracture toughness with temperature and time plays a main role in RPV failure at the end of the cool-down process. As expected, the failure probability increases with increasing fluence, Cu and Ni contents, and initial reference temperature-nil ductility transition ($RT_{NDT}$). The effect of warm prestressing on the vessel failure probability for LTOP is not significant because most of the failures happen before the stress intensity factor reaches the peak value while its effect reduces the failure probability by more than one order of magnitude for the cool-down transient.

Top-Down 공법이 적용된 흙막이벽의 역해석을 이용한 거동분석 (The Behavior of Earth Retaining Walls Applied to Top-Down Construction Method Using Back Analysis)

  • 홍원표;강철중;윤중만
    • 지질공학
    • /
    • 제22권1호
    • /
    • pp.39-48
    • /
    • 2012
  • 본 연구에서는 흙막이벽 설계시 널리 사용되고 있는 SUNEX 프로그램을 이용하여 Top-Down 공법이 적용된 지중연속벽, 주열식 흙막이벽(CIP벽, SCW벽)의 변형거동을 분석하였다. 해석프로그램에 Rankine의 토압(1857), Terzaghi and Peck의 토압(1967), Tschebotarioff의 토압(1973), 홍원표 윤중만의 토압(1995a)을 적용하여 흙막이벽의 수평변위를 예측하였다. 프로그램 해석결과, 흙막이벽의 수평변위량은 토압의 종류에 따라 큰 차이를 나타내고 있다. 홍원표 윤중만의 토압(1995a)을 적용하여 얻은 흙막이벽의 예측수평변위량이 실측수평변위량과 가장 유사하게 나타났다. 따라서 프로그램 해석시 홍원표 윤중만의 경험토압(1995a)을 적용하면, Top-Down 공법이 적용된 흙막이벽의 변형거동을 비교적 정확히 예측할 수 있다.

Top-Down 공법이 적용된 지중연속벽의 설계시 측방토압의 적합성 평가 (Suitability Evaluation of Lateral Earth Pressure for Design Diaphragm Walls applied to the Top-Down Construction Method)

  • 홍원표;강철중;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제11권1호
    • /
    • pp.11-21
    • /
    • 2012
  • 본 연구에서는 지중연속벽 설계시 사용되는 범용 해석프로그램에 Rankin(1857)의 이론토압과 홍원표와 윤중만(1995a)의 경험토압을 각각 적용하여 Top-Down 공법에 적용된 지중연속벽의 수평변위를 분석하였다. 그리고 이들 해석 프로그램에서 산정된 예측변위량과 지중경사계로 측정된 실측변위량을 비교 검토하였다. 현재 지중연속벽 설계에 적용되는 해석프로그램에는 Rankine의 토압이 주로 적용되고 있다. 검토결과, 지중연속벽의 예측수평변위는 적용되는 토압에 따라 상당히 큰 차이를 나타내고 있다. Rankine의 토압을 적용하여 산정된 예측수평변위 형상은 실측결과와 큰 차이를 보이고 있으며 벽체의 하부에서 예측치가 실측치보다 과다하게 산정되었다. 반면, 홍원표 윤중만의 토압을 적용하여 얻은 예측수평변위 형상과 최대수평변위량은 실측결과와 유사하게 나타났다. 따라서 Top-Down 공법이 적용된 지중연속벽의 설계시 Rankine의 토압보다는 홍원표 윤중만의 경험토압을 적용하는 것이 적합함을 알 수 있다.

An Empirical Study for the Safe and Effective Operations in Membrane LNG Ships focused on the Tank Cool Down

  • Gim, S.G.;Kim, S.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.566-572
    • /
    • 2005
  • The most crucial factor in membrane LNG ships to ensure sage operations, is how to effectively control tank pressure at the time of excessive generation of boil off gas (BOG). When the ships carry out tank cool down with her retaining heel prior to arrival at loading port, the vessel encounters the critical situation of excessive BOG and high tank pressure that can lead to high degree of risk. This is to provide one of the best ways to secure safe and effective LNG ship operations focusing on the detailed methods of tank cool down to achieve ATR(Arrival Temperature requirement) without building up high tank pressure and excessive BOG and calculating the appropriate heel quantity to be unutilized for tank cool down and fuel during ballast voyage.

  • PDF

초기충전압력이 쥴톰슨냉동기의 강온에 미치는 영향 (Effects of the initial charging pressure of gas on the cool-down characteristics of the Joule-Thomson cryocooler)

  • 홍용주;박성제;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2160-2164
    • /
    • 2008
  • Miniature Joule-Thomson cryocoolers have been widely used for rapid cooling of infrared detectors, probes of cryosurgery, thermal cameras, missile homing head and guidance system, due to their special features of simple configuration, compact structure and rapid cool-down characteristics. The cool-down time, the temperature at the cold end, the running time and the gas consumption are the important indicators of the performance of the J-T cryocooler. In this study, the initial cool-down stages of the J-T cryocooler were investigated by numerical simulations. The results show the effects of the initial charging pressures of gas on the cool-down time and the temperature at the cold end and the gas consumptions.

  • PDF

맥진 가압 프로파일 측정 시스템 개발 (Development of Pulse Diagnosis Hold-down Pressure Measurement System)

  • 이전;이유정;전영주;유현희;우영재;김종열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1997-1998
    • /
    • 2008
  • Pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors. Although the pulse diagnosis position, Gwan is apart from Chon or Cheok by 10$\sim$20mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Chon, Gwan and Cheok. One the other hand, the education on pulse diagnosis behavior includes tantalizing problem caused by no tool for communication between trainer and trainee. On account of this situation, we tried to develop a system which can measure the hold-down pressure during a pulse diagnosis and compare the hold-down pressure profile of trainer and that of trainee. This system can be divided into three parts - pulse pressure sensing part, signal acquisition part and data storing part. A correction curve was generated by the relation between output voltages and standard weights. Using this system, 3 channel hold-down pressure profile of a oriental medical doctor were recorded three times. In the profile, three period were observed and all period included two process for searching the depth of pulsation and for classifying the pulse feeling into one or more of 28 pulse types. The maximum value of pulse profile was 1.3$kg{\cdot}f$ which was more than reported by previous chinese groups and the mean values of three channel ranged from 240$g{\cdot}f$ to 430$g{\cdot}f$. In frequency domain, each channel has some dominant frequency components - about 10Hz, 35Hz and 75Hz. In further study, we want to collect more profiles from lage number of oriental medicine doctors and hope to develop a measuring system which can measure the hold-down pressure on subject's skin directly.

  • PDF