• 제목/요약/키워드: Pressure control algorithm

검색결과 284건 처리시간 0.023초

이산화탄소에어컨의 효율적인 운용을 위한 실용알고리즘 (Practical Algorithms for the Effective Operation of a $CO_2$ Air-conditioner)

  • 한도영;박승호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.435-440
    • /
    • 2009
  • For the effective control of a $CO_2$ air-conditioning system, the system high-side pressure algorithm, the indoor temperature algorithm, and the outdoor fan algorithm were developed. The system high-side pressure algorithm was composed of the setpoint algorithm, the reset algorithm, and the electronic expansion valve control algorithm. The indoor temperature algorithm was composed of the compressor control algorithm and the indoor fan control algorithm. These algorithms were tested by using mathematical models developed from the previous study. Results from the setpoint step change test and the disturbance test showed good control performances. Therefore, algorithms developed in this study may practically used for the control of a $CO_2$ air-conditioning system.

  • PDF

전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증 (Verification of Control Algorithm for Removing Oil Contaminant Factor from Proportional Pressure Control Valve)

  • 천수환;박진감;장경제;심성보;장민호;이진웅
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권4호
    • /
    • pp.1-8
    • /
    • 2021
  • An electro proportional pressure control valve is mainly used to control the clutch of an agricultural tractor's automatic transmission. During transmission, the operating, hydraulic oil is mix with many kinds of contaminants. The contaminants can be trapped between the valve body and spool of the proportional pressure control valve leading to abnormal operating conditions and finally critical damage to the transmission hydraulic system. The present study aimed to verify the valve control algorithm as a basic study of developing control logic that removes contaminants between the spool and the body of the proportional pressure control valve. To develop the algorithm, MATLAB/SIMULINK was used. PWM method was used to control the applied solenoid coil current. The effectiveness of the algorithm was verified by comparing the actual pressure of the normal valve with the actual pressure of the abnormal valve. Based on the present study findings, when the algorithm was applied, the response of the valve pressure according to the current became stable and oil contaminated particles were removed. In the future study, the control algorithm will be optimized for the stability of the proportional pressure reducing valve, and it will be verified in consideration with the driving of the clutch.

GA를 이용한 전기유압식 가변펌프의 압력제어 (Pressure Control of Electro-Hydraulic Variable Displacement Pump Using Genetic Algorithms)

  • 안경관;현장환;조용래;오범승
    • 한국정밀공학회지
    • /
    • 제21권9호
    • /
    • pp.48-55
    • /
    • 2004
  • This study presents a genetic algorithm-based method fur optimizing control parameters in the pressure control of electro-hydraulic pump with variable displacement. Genetic algorithms are general-purpose optimization methods based on natural evolution and genetics and search the optimal control parameters maximizing a measure that evaluates the performance of a system. Four control gains of the PI-PD cascade controller for an electro-hydraulic pressure control system are optimized using a genetic algorithm in the experiment. Optimized gains are confirmed by inspecting the fitness distribution which represents system performance in gain spaces. It is shown that genetic algorithm is an efficient scheme in optimizing control parameters of the pressure control of electro-hydraulic pump with variable displacement.

개량된 PWM 알고리즘을 이용한 공압 레귤레이터의 압력제어에 관한 연구 (A Study on Pressure Control of Pneumatic Regulator using Modified PWM Algorithm)

  • 김형석;안경관;이병룡;윤소남
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.64-70
    • /
    • 2005
  • The development of an accurate and energy saving pneumatic regulator that may be applied to a variety of practical pressure control applications is described in this paper. A novel modified pulse width modulation(MPWM) valve pulsing algorithm allows the pneumatic regulator to become energy saying system. A comparison between the system response of conventional PWM algorithm and that of the modified PWM(MPWM) algorithm shows that control performance is almost the same, but energy saving is greatly improved by adopting this new MPWM algorithm. The effectiveness of the proposed control algorithm are demonstrated through experiments with various reference trajectories.

Fuzzy SOC를 이용한 하이드로 포밍 고정의 압력제어기 설계 (A fuzzy SOC based pressure tracking controller design for hydroforming process)

  • 김문종;박희재;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.350-355
    • /
    • 1990
  • A pressure tracking of hydroforming process is considered in this paper. To account for nonlinearities and uncertainty of the process. A fuzzy SOC based iterative learning control algorithm is proposed. A series of experimentals were performed for the pressure tracking control of the process. The experimental results show that regardless of inherent nonlinearties and uncertainties associated with hydraulic system. A good pressure tracking control performance is obtained using the proposed fuzzy learning control algorithm.

  • PDF

다입력변수를 사용한 멀티형 공조시스템 압축기와 전자팽창밸브의 퍼지 제어 알고리즘 (Fuzzy Control Algorithms for the Compressor and the Electronic Expansion Valve of a Multi-type Air-conditioning System using Multiple Input Variables)

  • 한도영;박관준
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.163-171
    • /
    • 2006
  • In order to control multi-zone temperatures, a multi-type air-conditioning system may be used. In this study, control algorithms for the compressor and the electronic expansion valve of a multi-type air-conditioning system were developed by using fuzzy logics. The compressor control algorithm was composed of a compressor pressure setpoint algorithm, a compressor pressure setpoint reset algorithm, and a compressor frequency setpoint algorithm. The electronic expansion valve control algorithm was composed of an indoor temperature control algorithm, and a superheat control algorithm. These algorithms were applied to a multi-type air-conditioning system. Test showed good results for the control of a multi-type air-conditioning system.

$CO_2$ 에어컨 시스템을 위한 고압재설정알고리즘의 성능분석 (Performance Analysis of the High-side Pressure Reset Algorithm for a $CO_2$ Air-conditioning System)

  • 한도영;노희전
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.393-398
    • /
    • 2008
  • In order to protect the environment from the refrigerant pollution, the $CO_2$ may be regarded as one of the most attractive alternative refrigerants for an automotive air-conditioning system. Control methods for a $CO_2$ system should be different because of the unique property of a $CO_2$ as a refrigerant. Especially, the high-side pressure of a $CO_2$ system should be controlled for the efficient operation. The high-side pressure algorithm being composed of the pressure setpoint algorithm and the pressure setpoint reset algorithm was developed. The pressure setpoint algorithm, by using a least square method, was developed. The pressure setpoint reset algorithm, by using a fuzzy logic and by using a proportional logic, was also developed and compared. Simulation results showed that a proportional logic was more practical than a fuzzy logic for the pressure setpoint reset algorithm.

  • PDF

적응 제어 방식을 이용한 혈압자동 조절기에 관한 연구 (A Study on the Automatic Pressure Controller Using Adaptive Control Algorithma)

  • 이상훈;김영철;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.648-651
    • /
    • 1986
  • Sometimes, there are conditions when rapid control of the hypertension needed such as malignant hypertension, and the preoperative pereparation of the hypertensive patient requiring emergency operation, etc. Using the adaptive control algorithm, the mean arterial pressure reduction is achived rapidly and safely in hypertensive rabbit. Among the adaptive control algorithms the pole assignment self tuning control algorithm is superial to the one step ahead minium variance control algorithm. The convergence time is less than 600 sec, and the standard deviation of experimental data are less than 4 mmHg.

  • PDF

QFT를 이용한 디젤엔진의 커먼레일 압력 제어알고리즘 설계 연구 (Common Rail Pressure Control Algorithm for Passenger Car Diesel Engines Using Quantitative Feedback Theory)

  • 신재욱;홍승우;박인석;선우명호
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.107-114
    • /
    • 2014
  • 이 연구에서는 Quantitative Feedback Theory(QFT) 기법을 이용한 승용디젤엔진의 커먼레일 압력제어 알고리즘을 제안하였다. 커먼레일 압력모델의 입력과 출력은 각각 Pressure Control Valve(PCV) 구동전류와 커먼레일 압력으로 정의하였고, Metering Unit(MeUn)이 커먼레일 압력에 미치는 영향은 모델 파라미터 불확실성으로 정의하였다. QFT 기법은 이러한 모델의 불확실성에 대하여 강건하면서도 정량적 요구사항을 만족할 수 있는 제어알고리즘 설계방법을 제시한다. 제안된 커먼레일 압력제어기는 목표 레일압력 추종성능과 안정성능이 확보되었으며, 인젝터에 의한 연료분사가 커먼레일 압력에 미치는 영향을 줄이기 위하여 외란제거성능(Disturbance Rejection)이 고려되었다. 설계된 제어 알고리즘은 엔진 동력계 실험을 통하여 검증하였으며, MeUn 구동전류와 연료분사량의 급격한 변화에 따른 제어알고리즘의 강건성과 외란제거성능을 검증하였다.

음향 인텐시티를 이용한 관 외부 방사 소음의 능동 제어 (Active Control of External Noise Radiated From Duct Using Sound Intensity)

  • 강성우;김양한
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.427-437
    • /
    • 1997
  • Mean active intensity based active control for the cancellation of radiated noise out of the duct exit is studied. The active intensity control strategy is drerived based on the relation of the exterior sound field out of the duct termination and interior sound field of the duct. One of the characteristics of this control strategy is that the control performance can be maintained regardless of the sensor loction, compared with the conventional local pressure control methods at either interior downstream or exterior field positions. It is also suggested that the digital filtering for the active intensity control can be achieved by time-domain filtered-x LMP (Lest-Mean-Product) adaptive algorithm. Experiments for an open-ended duct are performed to compare the active intensity control performance with conventional pressure control one. Active control experiment of local sound pressure is conducted by widely used filtered-x LMS adaptive Algorithm and active intensity control implementaion uses the derived filter d-x LMP algorithm. It is shown that the exterior sound fileds was much better observable by sensing of the active intensity than by just sound pressure. It is also demonstrated that the global control performance of external field by acoustic intensity is superior to the conventional sound pressure control performance.

  • PDF