• Title/Summary/Keyword: Pressure Test

Search Result 7,883, Processing Time 0.035 seconds

Pressure Drop and Leakage Performances of Flat Seals with Inclined Grooves (경사 그루브를 갖는 평판 실의 압력 강하 및 누설 성능)

  • Jung, Jin Woo;Jeong, Gwon Jong;Hwang, Sung Ho;Kim, Tae Ho;Kim, Eojin
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.213-221
    • /
    • 2022
  • This paper presents performance measurements of pressure drop and leakage flow rate of test flat seals with asymmetric inclined grooves. This study aims to reveal the influence of groove shapes, often machined in radial film riding-face seals, in forming a hydrodynamic wedge on leakage performance. A test facility was developed, and test seals were manufactured to study the effects of the inlet pressure level, ratio of inlet to outlet pressure, seal groove length, and seal groove height on the steady-state pressure drop and leakage performance. A series of tests were conducted, and the test data were compared to the predictions from a simple and efficient mathematical model using a one-dimensional Reynolds equation. The test results revealed that an increase in the inlet pressure increased the pressure drop through the test seals. The leakage flow rate increased significantly as the inlet pressure and ratio of the inlet to outlet pressure increased. The groove shape also affects seal performance. An increase in the groove length and height resulted in an evident increase in the leakage flow rate. The simple model predictions underestimated the leakage flow rates but showed good agreement with the trend in the measurements for all test operating conditions and changes in the groove shape.

Manufacture of High-temperature High-pressure Vessel for Mixed Gas Performance Test via Optimized Design (최적화 설계를 통한 혼합가스 성능시험용 고온 고압 용기의 제작)

  • Ku, Hyoun-Kon;Ryu, Hyung-Min;Ahn, Jae-Woong;Bae, Young-Gwan;Kim, Jin-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.11
    • /
    • pp.83-88
    • /
    • 2019
  • In this study, the high-temperature high-pressure vessel was successfully manufactured, which can be used to store pressurized air and to increase the temperature for the mix performance test of high-temperature high-pressure air with coolant (e.g., water). In this research, static structure analysis and transient thermal analysis were performed using the commercial software Midas NFX 2015 R1. Based on the results, the optimized pressure vessel design was carried out. As a result of the optimized design, the minimum stress and minimum weight were found at 120 mm of the vessel thickness, and the optimized pressure vessel was verified. Finally, through manufacture and performance test (e.g., the non-destructive inspection and hydraulic pressure test), the reliability and safety were validated for the designed pressure vessel.

Identification of ambient pore pressure and rigidity index from piezocone dissipation test (피에조콘 소산시험을 이용한 평형간극수압과 강성지수의 역해석)

  • 김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.49-54
    • /
    • 2002
  • This paper describes a systematic way of simultaneously identifying the ambient pore pressure and the rigidity index (=G/s$\_$u/) of soil by applying an optimization technique to the piezocone dissipation test result. An ambient pore pressure and optimal rigidity index were determined by minimizing the differences between theoretical excess pore pressures developed by Randolph & Wroth(1979) and measured excess pore pressures from piezocone using optimization technique. The effectiveness of the proposed back-analysis method was examined against the well-documented performance of piezocone dissipation tests (Tanaka & Sakagami, 1989), from the viewpoints of proper determination of selected target parameters and saving of test duration. It is shown that the proposed back-analysis method can evaluate properly the ambient pore pressure and the rigidity index by using only the early phase of the dissipation test data. Also, it is shown that with the optimized rigidity index and ambient pore pressure the proposed back-analysis method permits the horizontal coefficient of consolidation to be identified rationally.

  • PDF

A Study on a Quality Characteristics of Pressure Leak Test of Process Piping for Offshore Plant (해양플랜트 프로세스 배관 Pressure Leak Test의 품질 특성에 관한 연구)

  • Park, Chang-Soo;Kim, Hyungwoo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.429-437
    • /
    • 2018
  • The process gas piping of the offshore plant can cause a massive explosion if the gas leakage occurs during operation. For the purpose of precaution of gas leakage accident, an air pressure test is performed on the process equipment tests using a test pump as much as the power to the piping inner side, mix 99% nitrogen gas and 1% helium gas. The purpose of the air pressure test is to check the work conformity process by handling and regulation for initial piping process, assembly, installation of module, welding, center alignment of the pipes assembling flange gasket in an unrestrained free state. In this paper, the regulation of the problematic air pressure test was analyzed and the solution criteria were established. And leakage tests of existing equipment were performed applying these solution methods. As a result, it was confirmed that there was no problem.

An Experimental Study on the Consolidation Characteristics with Loading Rate (재하속도에 따른 압밀특성에 관한 실험적 고찰)

  • Chae, Jum-Sik;So, Chung-Sup;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1070-1077
    • /
    • 2005
  • The purpose of this study is to establish a proper criterion for the constant rate of loading consolidation(CRLC) test which is a kind of the continuous loading consolidation(CLC) and widely used as alternative methods to the incremental loading consolidation(ILC)test. With those results, the preconsolidation pressure estimated by the CRLC test turned out to be comparatively larger than that of the ILC test, and it is increased in proportion to the applied loading rates. However, the compression index in the CRLC test is less influenced on by the loading rates. The coefficient of consolidation and permeability in the CRLC test are dependent on excess pore pressure ratio mainly. In other words, if the pore pressure ratios are too low, the coefficient of consolidation and permeability become smaller than those of the ILC test. On the other hand, if the excess pore pressure ratios are too high, the coefficient of consolidation and permeability become so larger than those of the ILC test. Therefore, loading rates should be carefully determined to generate proper excess pore pressure ratio inside the soil specimen. From this study, good results are obtained from the CRLC test if the excess pore pressure ratios were in the range of 2.5 to 6.0 %, performed with loading rates between 0.0015 and 0.005 $kgf/cm^2/min$.

  • PDF

A Study on the Pore Pressure Dissipation Test of the Piezocone (피에오콘의 간극수압 소산시험에 관한 연구)

  • 황대진;김철웅
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.25-36
    • /
    • 1997
  • A degree of consolidation at any time can be evaluated by using cone penetration test after soil improvement. In this case, after stopping the penetration of a piezocone, pore pressure dissipation(PPD) best is carried out until the pore pressure remains constant. Since the hydraulic conductivity of soft ground is very small, it takes very long time to finish the PPD test. This research is performed to develop a method overcoming this problem of the PPD test and reducing the test time. The analyses are carried out in the following ways : an equilibrium pore pressure can be determined by using pore pressure measured in the middle of the test, which is predicted by hyperbolic, Asaoka and Hoshino methods. And this equilibrium pore pressure is compared with the one measured in a test of long duration. As a result of the study, it is found that Hoshino method is the best way to predict the equilibrium pore pressure in a teat of short duration. And it is proposed as a methodology to fond a minimal time in which we can get an equilibrium pore pressure.

  • PDF

Estimating of water pressure to avoid hydraulic fracturing in water pressure test

  • Amnieh, Hassan Bakhshandeh;Masoudi, Majid
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.171-177
    • /
    • 2017
  • Water pressure test operation is used before the grouting to determine the rate of penetrability, the necessity and estimations related to grouting, by the penetration of water into the borehole. One of the parameters which have the highest effect is pressure of water penetration since the application of excessive pressure causes the hydraulic fracture to occur in the rock mass, and on the other hand, it must not be so small that prevents from seeing mechanical weaknesses and the rate of permeability. Mathematical modeling is used for the first time in this study to determine the optimum pressure. Thus, the joints that exist in the rock mass are simulated using cylindrical shell model. The joint surroundings are also modeled through Pasternak environment. To obtain equations governing the joints and the surroundings, energy method is used accompanied by Hamilton principle and an analytical solution method is used to obtain the maximum pressure. In order to validate the modeling, the pressure values obtained by the model were used in the sites of Seymareh and Aghbolagh dams and the relative error rates were measured considering the differences between calculated and actual pressures. Modeling in the sections of Seymareh dam showed 4.75, 3.93, 4.8 percent error rates and in the sections of Aghbolagh dam it rendered the values of 22.43, 5.22, 2.6 percent. The results indicate that this modeling can be used to estimate the amount of pressure for hydraulic fracture in water pressure test, to predict it and to prevent it.

Development of Turbopump Cavitation Performance Test Facility and the Test of Inducer Performance (터보펌프 Cavitation 성능시험기 개발 및 성능시험에 관한 연구)

  • Sohn, Dong-Kee;Kim, Chun-Tak;Yoon, Min-Soo;Cha, Bong-Jun;Kim, Jin-Han;Yang, Soo-Seok
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.619-624
    • /
    • 2001
  • A performance test facility for turbopump inducer cavitation was developed and the inducer cavitation performance tests were performed. Major components of the performance test facility are driving unit, test section, piping, water tank, and data acquisition and control system. The maximum of testing capability of this facility are as follows: flow rate - 30kg/s; pressure - 13 bar; rotational speed 10,000rpm. This cavitation test facility is characterized by the booster pump installed at the outlet of the pump that extends the flow rate range, and by the pressure control system that makes the line pressure down to vapor pressure. The vacuum pump is used for removing the dissolved air in the water as well as the line pressure. Performance tests were carried out and preliminary data of test model inducer were obtained. The cavitation performance test and cavitation bubble flow visualization were also made. This facility is originally designed for turbopump inducer performance test and cavitation test. However it can be applied to the pump impeller performance test in the future with little modification.

  • PDF

Case Study of Flexural Strength Evaluation of Epoxy Injected Concrete Using Low Pressure Mixed with Mechanical High Pressure (기계식 고압과 저압을 혼용한 에폭시 주입 콘크리트의 휨강도 검토 사례 연구)

  • Hong, Ki-Nam;Yu, Yeon-Jong;Lee, Kang-Moon;Ryu, Chang-Yeol;Yoon, Hong-Su
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.49-54
    • /
    • 2012
  • The objective of this study is to investigate the capacity of epoxy injection method using low pressure mixed with high pressure. Injection depth test and flexural strength test were respectively performed on $40{\times}45{\times}35$ cm and $100{\times}10{\times}40$ cm specimens. Considered as the test variables were injection type(low pressure, low and high pressure), crack width(0.25 mm, 0.50 mm), injection direction(upper, lower, side), and epoxy viscosity(low, medium, high). Test results showed that low viscosity epoxy injection depth of injector using low pressure mixed with high pressure for upper direction were 23 cm and tension strength of crack face repaired by injector using low pressure mixed with high pressure was larger than that of concrete.

Analysis of Blood Pressure Pulse in Female High School Students with Menstrual Disorders (월경장애를 가진 여고생의 맥진분석)

  • Kim, Soo-Hyun;Cho, Hye-Sook;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.1
    • /
    • pp.82-91
    • /
    • 2013
  • Objectives: The purpose of this study is to find out the patterns of teenage girls who is easy to suffer from Menstrual Disorders. Methods: The data from the 1681 participants were collected using a structured menstrual history questionnaire. Based on the survey responses, we had 97 adolescents with menstrual disorder as the test group and 97 adolescents without menstrual disorder as the control group. The clinical trials subjects were asked to respond to another questionnaire for identifying Blood Pressure Pulse Analyzer tests. We identified significant variables for dysmenorrhea from comparison between the test and control group; a binary response variable from the test group's responses for ever experiencing dysmenorrhea and explanatory variables from Blood Pressure Pulse Analyzer. Results: The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in dysmenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower, and T4_R were higher in hypomenorrhea group than the control group. The reselts of Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in Irregular Menstruation group than the control group. Conclusions: Blood Pressure Pulse Analyzer test showed that the score of Energ_R, EIX_R were lower in the test group than the control group.