• 제목/요약/키워드: Pressure Sensor

검색결과 1,580건 처리시간 0.033초

부방향 동압력을 이용한 압전형 압력센서의 교정기법 (A Dynamic Calibration Technique for Piezoelectric Sensors Using Negative Going Dynamic Pressure)

  • 김응수
    • 한국군사과학기술학회지
    • /
    • 제12권4호
    • /
    • pp.491-499
    • /
    • 2009
  • The determination of response characteristics for pressure sensors is routinely limited to static calibration against a deadweight pressure standard. The strength of this method is that the deadweight device is a primary standard used to generate precise pressure. Its weakness lies in the assumption that the static and dynamic responses of the sensor in question are equivalent. Differences in sensor response to static and dynamic events, however, can lead to serious measurement errors. Dynamic techniques are required to calibrate pressure sensors measuring dynamic events in milliseconds. In this paper, a dynamic calibration using negative going dynamic pressure is proposed to determine dynamic pressure response for piezoelectric sensors. Sensitivity and linearity of sensor by the dynamic calibration were compared with those by the static calibration. The uncertainty of calibration results and the goodness of fit test of linear regression analysis were presented. The results show that the dynamic calibration is applicable to determine dynamic pressure response for piezoelectric sensors.

과도상태의 압력데이터로부터 평형상태 압력 예측방법 연구 (A Study on the Method of Equilibrium-Pressure Prediction from Transient Data)

  • 이종국
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.19-28
    • /
    • 2004
  • 본 논문은 과도상태의 압력데이터로부터 평형상태의 압력을 예측하는 방법을 제시하고 있다. 압력을 측정하는 곳과 압력센서는 튜브로 연결되어져 있다. 측정하고자하는 압력 (측정압력)이 높은 경우에는 압력센서가 빠른 시간 내에 측정압력에 반응을 한다. 그러나 매우 낮은 압력을 측정하는 경우에는 압력센서가 실시간으로 측정압력에 반응을 하지 못하여 압력지연현상이 발생하게 된다. 이러한 압력지연현상을 파악하고자 여러 가지 실험이 수행되었다. 본 연구의 제시된 평형압력예측방법은 낮은 압력을 측정함에 있어서 측정시간을 단축시킬 수 있다.

고온 단결정 3C-SiC 압저항 압력센서 특성 (Characteristics of high-temperature single-crystalline 3C-SiC piezoresistive pressure sensors)

  • 판 투이 탁;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.274-274
    • /
    • 2008
  • This paper describes on the fabrication and characteristics of a 3C-SiC (Silicon Carbide) micro pressure sensor for harsh environment applications. The implemented micro pressure sensor used 3C-SiC thin-films heteroepitaxially grown on SOI (Si-on-insulator) structures. This sensor takes advantages of the good mechanical properties of Si as diaphragms fabricated by D-RIE technology and temperature properties of 3C-SiC piezoresistors. The fabricated pressure sensors were tasted at temperature up to $250^{\circ}C$ and indicated a sensitivity of 0.46 mV/V*bar at room temperature and 0.28 mV/V*bar at $250^{\circ}C$. The fabricated 3C-SiC/SOI pressure sensor presents a high-sensitivity and excellent temperature stability.

  • PDF

무연솔더를 이용한 실리콘 압력센서의 플립칩 패키지 (Flip-Chip Package of Silicon Pressure Sensor Using Lead-Free Solder)

  • 조찬섭
    • 한국산업융합학회 논문집
    • /
    • 제12권4호
    • /
    • pp.215-219
    • /
    • 2009
  • A packaging technology based on flip-chip bonding and Pb-free solder for silicon pressure sensors on printed circuit board (PCB) is presented. First, the bump formation process was conducted by Pb-free solder. Ag-Sn-Cu solder and the pressed-screen printing method were used to fabricate solder bumps. The fabricated solder bumps had $189-223{\mu}m$ width, $120-160{\mu}m$ thickness, and 5.4-6.9 standard deviation. Also, shear tests was conducted to measure the bump shear strength by a Dage 2400 PC shear tester; the average shear strength was 74 g at 0.125 mm/s of test speed and $5{\mu}m$ shear height. Then, silicon pressure sensor packaging was implemented using the Pb-free solder and bump formation process. The characteristics of the pressure sensor were analogous to the results obtained when the pressure sensor dice are assembled and packaged using the standard wire-bonding technique.

  • PDF

다이어프램형 압력센서에서 주변 온도에 의한 오차 보상 (Error Compensation due to Environmental Temperature for Diaphragm-Type Pressure Sensor)

  • 윤대중;안중환;이길승;김화영
    • 센서학회지
    • /
    • 제28권3호
    • /
    • pp.177-181
    • /
    • 2019
  • Pressure sensors are used in various industries such as automobiles, airplanes, medical equipment, and coolers. Even if the ambient temperature changes, the measurement is reliable and stable. In this study a diaphragm-type pressure sensor was used to derive a temperature-compensated pressure estimation equation for accurate pressure measurement at $100^{\circ}C$ and $-40^{\circ}C$. To understand the characteristics of the pressure sensor diaphragm with respect to temperature and pressure, experiments were conducted in temperature-variable chamber using FEM analysis to confirm that the influence of temperature effect was nonlinear. Based on the experimental results, a nonlinear method for calculating the pressure by compensating for the error due to temperature was derived. The calculated pressure value is lower than 0.5 % at low and high temperatures, and lower than 0.4 % at $22^{\circ}C$, thereby eliminating the effect of temperature.

디지탈 출력 압력 센서 (Digitized Pressure Sensor)

  • 김현철;전국진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.419-421
    • /
    • 1996
  • We propose the digitized pressure sensor and the interface circuit to read directly the pressure signal in the digital form. The interface circuit has the control clock, comparator, and bit value decision circuit. The digitized sensor and interface circuit are integrated on the one chip using the post processing after IC fabrication. The dimension of the fabricated digitized pressure sensor is $3{\times}6{\times}1mm^3$.

  • PDF

하퇴 의지 사용자의 족저압 분포 특성에 관한 연구 (A Study of Characteristics of Foot Pressure Distribution in Trans-tibial Amputee Subjects)

  • 김장환;신헌석
    • 한국전문물리치료학회지
    • /
    • 제8권3호
    • /
    • pp.1-10
    • /
    • 2001
  • The purpose of this study was to compare the static pressure, dynamic pressure, dynamic pressure-time integral, relative impulse, and contact time between the sound lower limb and amputated lower limb in trans-tibial amputee subjects using Parotec system. Seventeen trans-tibial amputee subjects wearing endoskeletal trans-tibial prosthesis voluntarily participated in this study. The results were as follows: 1) In static standing condition, there were significantly higher static pressure in sound lower limb insole sensor of 10, 14, 15, 18, 19, 23, and 24 and in amputated lower limb insole sensor of 9, 12, and 16 (p<.05). 2) In dynamic gait condition, there were significantly higher dynamic pressure in sound lower limb insole sensor of 2, 18, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, 14, 15, and 16 (p<.05). 3) In dynamic gait condition, there were significantly higher pressure-time integral in sound lower limb insole sensor of 2, 4, 18, 19, 20, 21, 23, and 24 and in amputated lower limb insole sensor of 5, 11, 12, and 15 (p<.05). 4) In dynamic gait condition, there were significantly higher relative impulse in sound lower limb insole sensor of 18, 19, 20, 22, 23, and 24 and in amputated lower limb insole sensor of 5, 9, 10, 11, 12, and 15 (p<.05). 5) In dynamic gait condition, there was significantly higher percentage of contact time in push off phase of sound lower limb and in support phase of amputated lower limb (p<.05). These results suggest that trans-tibial amputee subjects had characteristics of shortened push off phase due to unutilized forefoot and of lengthened support phase with higher pressure in the midfoot.

  • PDF

Sheath-core 구조 전도사 섬유센서의 Home-Textile 적용을 위한 전기·물리학적 특성연구 (Electrical and Physical Properties of Sheath-core Type Conductive Textile Sensor with Home-Textile)

  • 조광년;정현미
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.145-152
    • /
    • 2014
  • The usage of textile-based sensors has increased due to their many advantages (compared to IT sensors) when applied to body assessment and comfort. Textile-based sensors have different detecting factors such as pressure, voltage, current and capacitance to investigate the characteristics. In this study, textile-based sensor fabrics with sheath-core type conductive yarns were produced and the relationship between capacitance changes and applied load was investigated. The physical and electric properties of textile-based sensor fabrics were also investigated under various laminating conditions. A textile based pressure sensor that uses a sheath-core conductive yarn to ensure the stability of the pressure sensor in the textile-based sensor (the physical structure of the reaction characteristic of the capacitance) is important for the stability of the initial value of the initial capacitance value outside the characteristic of the textile structural environment. In addition, a textile based sensor is displaced relative to the initial value of the capacitance change according to pressure changes in the capacitance value of the sensor due to the fineness of the high risk of noise generation. Changing the physical structure of the fabric through the sensor characteristic of the pressure sensor via the noise generating element of laminating (temperature, humidity, and static electricity) to cut off the voltage output element to improve the data reliability could be secured.

스테인레스 봉입형 반도체 압력센서의 제작 및 그 특성 (Construction and Characterization of the Stainless Steel Isolated Type Semiconductor Pressure Sensor)

  • 김우정;조용수;황정훈;최시영
    • 센서학회지
    • /
    • 제11권3호
    • /
    • pp.138-144
    • /
    • 2002
  • 스테인레스 봉입형 압력센서를 제작하기 위하여 먼저 반도체 제조 및 식각 공정을 통하여 반도체 압력센서를 제작하였다 그리고 이를 glass molding된 스테인레스 housing에 올려놓고 $50\;{\mu}m$ 두께의 스테인레스 박판을 용접한 후 실리콘 오일을 채워 넣고 봉입하여 압력 범위 10 bar 센서를 완성하였다. 이와 같이 제작한 센서와 XTR105 발신기 전용 회로를 결합하여 $4{\sim}20\;mA$ 출력의 압력 발신기를 제작하고 그 특성을 조사하였다. 온도 보상 전 정확도는 ${\pm}5%$ FS이었으나 보상 후 정확도 ${\pm}1%$ FS로 개선되었다.

공기청정기 시험기의 센서신호 오차가 공기청정기 성능 평가에 미치는 영향 (Effects of Sensor Errors in Air Cleaner Testing on the Cleaner Performance Estimation)

  • 이천환;김민영;이수민
    • 한국수소및신에너지학회논문집
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2023
  • The fuel cell in fuel cell electric vehicle utilizes oxygen in the atmosphere, which requires the use of an air cleaner system to minimize the intake of harmful pollutants. To estimate the performance of the air cleaner system, the pressure drop between the filter inlet and outlet is used under the rated air flow condition. In this study, the effect of sensor error in this air cleaner testing is experimentally carried out. It is found that the errors of the temperature sensor does not significantly affect the estimation of pressure drop. However, in the case of the pressure sensor, 5% sensor error results in the error of pressure drop estimation by 3%. Therefore, it is recommended that the measurement accuracy of the pressure sensor mounted in test system should be maintained at less than 5%.