• Title/Summary/Keyword: Pressure Point

Search Result 2,196, Processing Time 0.029 seconds

A Numerical Analysis on the System Impedance in a Fan Cooling System (Fan 냉각장치에서 System 저항에 관한 수치해석)

  • Kim, Dong-Il;Bok, Ki-So;Lee, Seung-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1424-1429
    • /
    • 2004
  • To seek the fan operating point on a cooling system with fans, it is very important to determine the system impedance and it has been usually examined with the fan tester(wind tunnel) based on ASHRAE standard and AMCA standard. This leads to a large investment in time and cost, because it could not be executed until the system is made actually. Therefore it is necessary to predict the system impedance curve through numerical analysis so that we could reduce the measurement effort. This paper presents how the system impedance curve (pressure drop curve) is computed by CFD in substitute for experiment. In reverse order to the experimental principle of the fan tester, pressure difference was adopted first as inlet and outlet boundary conditions of the system and then flow rate was calculated.

  • PDF

Assessment of traffic-induced low frequency sound radiated from a viaduct by field experiment

  • Kawatani, M.;Kim, C.W.;Nishitani, K.
    • Interaction and multiscale mechanics
    • /
    • v.3 no.4
    • /
    • pp.373-387
    • /
    • 2010
  • This study is intended to assess low frequency sound radiated from a viaduct under normal traffic. The bridge comprises steel box girders and wide cantilever decks on which vehicles pass. The low frequency sound and the acceleration response of the bridge under normal traffic are measured to investigate how bridge vibrations affect the low frequency sound observed near the bridge. Observations demonstrate that strong relationships exist between frequency characteristic of bridge's acceleration response and the sound pressure level of low frequency sound. A noteworthy point is that the dynamic feature of the sound pressure level is mostly affected by dynamic feature of the span locating near the observation point.

A Study on Development of Electronic Blood Pressure Depressor of Meridian Point Discrimination Type

  • Kim, Jung-Ho;Lee, Jin-Woo;Son, Joon-Ho;Kim, Soon-Taek;Lee, Kwon-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.57.6-57
    • /
    • 2002
  • Recently, the seriousness of the high blood pressure appearing in the whole world as well as Korea. Therefore, the methods to treat this disease proposing. For exam pie, there are the medicinal therapy and the dietetic treatment, etc. But these are uncertain and produce an adverse reaction. Thereupon, we studied effectively and financially to execute the treatment of the high blood pressure based on oriental medicine. Oriental medicine includes many treatments. We used Meridian Theory, the Meridian point, and Acupuncture that are a part of oriental medicine and treatments. And actualizing the above explained treatment into electronic technique, we produced the same effect without the help of...

  • PDF

Acoustic Response of Hydrogen/Liquid Oxygen Flame in Stagnation-Point Flow (정체점 유동장에서 수소-액체산소 화염의 음향파 응답 특성)

  • Park, Sung-Woo;Chung, Suk-Ho;Kim, Hong-Jip
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.440-446
    • /
    • 2003
  • Steady-state structure and acoustic pressure responses of GH$_2$-LOx diffusion flames in stagnation-point flow configuration have been studied numerically with a detailed chemistry to investigate the acoustic instabilities. The Rayleigh criterion is adopted to judge the instability of the GH$_2$-LOx flames from amplification and attenuation responses at various acoustic pressure oscillation conditions for near-equilibrium to near-extinction regimes. Steady state flame structure showed that the chain branching zone is embedded in surrounding two recombination zones. The acoustic responses of GH$_2$-LOx flame showed that the responses in near-extinction regime always have amplification effect regardless of realistic acoustic frequency. That is, GH$_2$-LOx flame near-extinction is much sensitive to pressure perturbation because of the strong effect of a finite-chemistry.

Modal Analysis on SPL of the Periodic Structure depend on Unsymmetrical Beam Space (비대칭형 보강재 간격에 따른 주기구조물의 SPL모드 해석)

  • 김택현;김종태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.52-60
    • /
    • 2002
  • The purpose of this research is to study the vibration and acoustic pressure radiation from a thin isotropic flat plate stiffened by a rectangular array of beams, and excited by a time harmonic point force. These constructions on aircraft and ship structures are often subjected to fiequency dependent pressure fluctuations and forces. Forces from the these excitations induce structural vibrations in a wide range of fiequencies, which may cause such things as acoustic fatigue and internal cabin noise in the aircraft. It is thus important that the response characteristics and vibration modes of such periodic structures be horn. From this theoretical model, the sound pressure levels(SPL) in a semi-infinite fluid(water) bounded by the plate with the variation in the locations of an external time harmonic point farce on the plate can be calculated efficiently using three numerical tools such as the Gauss-jordan method the LU decomposition method md the IMSL numerical package.

Effects of Upset Pressure on Weldability in the Friction Welding of Cu to Cu-W Sintered Alloy (동-텅스텐 소결합금(Cu-W)과 동(Cu)의 마찰용접 특성에 미치는 업셋압력의 영향에 관한 연구)

  • 강성보;민택기
    • Journal of Welding and Joining
    • /
    • v.17 no.5
    • /
    • pp.69-76
    • /
    • 1999
  • A copper-tungsten sintered alloy(Cu-W) has been friction welded to a tough pitch copper in order to investigate the effect of upset pressure on friction weldability. Under the condition of friction time 0.8sec, upset pressure 150MPa, the tensile strength and Charpy impact value of the friction welded joint were 336MPa, $400KJ/m^2$ respectively. And highest temperature of the weld measured was below $800^{circ}K$ which is very lower than melting point of Cu($1356^{circ}K$). Under the same conditions, W grains picked up in Cu matrix from Cu-W profitably affected on these mechanical fracture, and were dispersed in Cu by plastic flow during brake time.

  • PDF

An Experimental Study on the Spray Behaviors of Swirl and Slit Injector to Direct Injection Spark Injection Engine (DISI 엔진용 스월인젝터와 슬릿인젝터의 분무 거동에 관한 연구)

  • Lee Changhee;Lee Kihyung;Choi Youngjong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.19-27
    • /
    • 2005
  • The spray characteristics of DISI injector has a great role in engine efficiency and emission. Thus, many researchers have been studied to investigate the spray characteristics of hollow cone type and slit type injector which are used in DISI engine. In this study, we tried to provide spray parameters which effect on the spray characteristics such as injection pressure, ambient pressure and ambient temperature. In addition, we calculated $t_b\;and\;t_c$ to investigate the break up mechanism of test injectors and also obtained $C_v$ to evaluate the spray characteristics. From this study, As the ambient pressure increases in case of slit injector, $C_v$ decreases.

Performance Assessment of Refrigerant Vapor-Pressure Equations with Two Adjustable Parameters (두 개의 가변 변수가 있는 냉매 증기압 상관식의 성능 평가)

  • Park, Kyoung-Kuhn
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-135
    • /
    • 2012
  • Performance of various temperature-dependent vapor-pressure equations with two adjustable parameters is assessed. These are Antoine, Miller, Zia-Thodos, Mejbri-Bellagi and other 10 equations. The equations are fitted to correlate the data from NIST Chemistry WebBook for 43 pure substance refrigerants from the critical point to the triple point. It was found that the Mejbri-Bellagi equation yields the lowest average absolute deviation of 0.37% compared with that of 0.58% of the Miller equation which is known to give better fit to experimental data than the Antoine equation(1.42%) does.

Relation between P-D value of Autopilot and Transfer Distance under Wind Pressure

  • Seong, Yu-Chang
    • Journal of Navigation and Port Research
    • /
    • v.32 no.4
    • /
    • pp.271-277
    • /
    • 2008
  • When performing steering by an autopilot (automatic steering gear), a sensitivity adjustment is mainly determined by P value and D value. These values differ in the optimal combination by model of ship and external forces. This research was carried out simulation case studies and examined movement of Pure Car Carrier, which easily received ship by wind pressure influence in low speed We investigated the relation of horizontal migration(transfer) of ship's body and P-D value. Based on it, four parameters of P-D at approaching berth could be suggested Hence there were suggestions of parameters; Distance to maximum lee point, Time to maximum lee point, Time to return to original course and Time to 300th second. The correlation of these parameters and P-D value were also considered. As a result, we think that this index, like formulated P-D, leads to an easy and safe navigation by utilizing these indices.

Analysis of the Rotational Behavior of Piles under Lateral Loading Installed in Multi Layered Soil (다층지반에 근입된 수평재하 말뚝의 회전거동 분석)

  • Kang, Beong-Joon;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.55-64
    • /
    • 2009
  • One of the important use of piles is to furnish lateral support and nowadays it is getting highlighted due to the increase of skyscrapers, transmission towers, wind turbines, and other lateral action dependent structures. After Broms (1964), many researchers have suggested methods for estimating lateral capacity of pile. But each method assumes different earth pressure distribution and lateral earth pressure coefficient causing confusion on the part of pile designers. Lateral earth pressure, essential in lateral capacity estimation, is influenced by pile's rotational behavior under lateral load. Prasad and Chari (1999) assumed the rotation point of pile and suggested an equation of ultimate lateral load capacity. In this study, we investigate the depth of rotation point in both homogeneous soil and multi layered soil, and compare with the estimation value by previous research. Test results show that measured rotation point and estimated value by Prasad and Chari's equation show good agreement and multi layered condition affects the location of rotation point to be changed.