• 제목/요약/키워드: Pressure Monitoring

검색결과 1,095건 처리시간 0.026초

실제 상수관망에 대한 모니터링 지점선정방법의 적용 (Application of the Determination Method of Monitoring Location in Real Water Distribution System)

  • 박용균;정성균;권혁재
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.617-623
    • /
    • 2015
  • In this study, determination methods of monitoring location in water distribution system were suggested and applied to real test bed. Small block of Gwangtan water distribution system is consisted of 582 pipes, 564 junctions, 1 reservoir, and 1 pump station. Small block of Ho Chi Minh water distribution system is consisted of 162 pipes, 148 junctions, and 1 reservoir. Two small block water distribution systems were analyzed by pressure contribution analysis method to determine the optimum monitoring locations. The pressure change was estimated at each junctions by the additional demand at a junction. From the results, the optimum monitoring location can be determined by rank of pressure contribution index at each junctions due to demand change at a junction.

자동차 센서 모니터링 시스템 개발 (Developmemt of automobile sensor monitoring system)

  • 최낙권;이상훈
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.150-155
    • /
    • 2005
  • We propose a newly developed automobile sensor monitoring system incorporated with a tire pressure monitoring sensor(TPMS). The RF-transmitter based on a tire pressure sensor, sends a frame data about measured tire-pressure to RF receiver. And the various sensing signals based on sensors such as fuel-level sensor, engine oil level sensor and temperature sensors, are converted into 10-bit digital data. The microprocessor displays converting data such as tire pressure, trip distance, fuel quantity, coolant temperature and car-room temperature, on LCD panel. The proposed system can be successfully adapted to monitoring of the tire pressure and various automobile sensors.

타이어 공기압 모니터링 시스템의 판단 로직 설계에 관한 연구 (A Study on the Design of decision logic for n Tire Pressure Monitoring System)

  • 김병우
    • 한국산학기술학회논문지
    • /
    • 제7권3호
    • /
    • pp.285-290
    • /
    • 2006
  • 자동차에 있어서 안전은 가장 중요한 설계 인자이다. 자동차 타이어 압력은 자동차 안전에 중요한 요소로 알려져 있다. 능동적 안전 측면에서, 타이어공기압검지장치(TPMS)는 아주 중요한 요소라 할 수 있다. RF 통신 기능을 갖고 타이어 내부에서 타이어 압력을 모니터링하는 장치는 광범위한 운전영역에서 정회한 압력을 검지하는 효과적 방법이다. 본 논문에서는 타이어 압력 및 온도보상 특성 관계를 조사하였다. 본 연구를 통하여, 차량 조건과 주행 변수를 고려한 TPMS 제어 로직의 가이드 라인을 설정할 수 있었다.

  • PDF

욕창 방지를 위한 체압 모니터링 시스템 개발 (Development of The Physical Pressure Monitoring System to Prevent Pressure Ulcers)

  • 이아라;장경배
    • 대한임베디드공학회논문지
    • /
    • 제6권4호
    • /
    • pp.209-214
    • /
    • 2011
  • This study suggests a Healthcare System for elderly and disabled who have mobility impairment and use a wheelchair for long time. Seating long time in a wheelchair without reducing pressure causes high risk of developing pressure sores. Pressure sores come with great deal of pain and often lead to develop complication. Not only it takes time and effort to treat pressure sores but also increases medical expenses. Therefore, we will develop a device to help to prevent pressure sores by measuring pressure distribution while seating in a wheelchair and wirelessly send information to user device to check pressure distribution in real time. The equipment to measure body pressure is composed of FSR sitting mat which is a sensor measuring part and an user terminal which is a monitoring part. The designed mat is matrix formed FSR sensor to measure pressure. The sensor send measured data to the controller which is connected to the end of the mat, and then the collected data are sent to an user terminal through a bluetooth. Developing a pressure monitoring system will help to prevent those who have mobility impairment to manage pressure sores and furthermore relieve their burden of medical expenses.

사출성형기 실린더와 금형 캐비티의 실시간 모니터링을 이용한 사출성형공정 비교 분석 (Comparative Analysis of Injection Molding Process by On-line Monitoring in Cylinder of Injection Molding Machine and in Cavity of Mold)

  • 박형필;차백순;태준성;최재혁;이병옥
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1513-1519
    • /
    • 2010
  • 최근 고품질 제품 생산을 위한 방법으로 센서를 이용한 사출공정모니터링 시스템이 적용되고 있다. 그러나 마이크로 금형, 광학용 금형 및 구조가 복잡한 금형에는 센서 설치가 어렵기 때문에, 공정 모니터링 시스템이 적용되기 어려운 단점이 있다. 본 연구에서는 금형과 사출성형기 노즐의 압력 을 측정하여 공정 모니터링 데이터의 정량적 지수를 정의하고, 성형품 중량에 대한 상관분석을 수행하여 노즐에 설치된 압력센서의 공정모니터링 적용성을 알아보았다. 또한 공정모니터링 데이터를 분석하여 다단사출속도, 보압 및 제한 사출 압력의 영향에 따른 사출성형기의 공정 제어 특성도 알아보았다.

유동속도에 따른 T-접합관의 유동소음에 관한 실험적 연구 (Experimental Study on Flow Noise in a T-Junction Pipe at Different Flow Velocity)

  • 후졘빈;류후린;왕카이;딩쾅신;진위보;류허밍;김형범
    • 한국가시화정보학회지
    • /
    • 제22권2호
    • /
    • pp.55-62
    • /
    • 2024
  • Using an internal flow noise test bench, this study investigates the variation in internal flow noise at the inlet and outlet monitoring points of a DN100 T-junction pipe under different flow velocities. Results indicate that with increasing flow velocity, both the sound pressure level and total sound pressure level at the inlet and outlet monitoring points increase. The highest total sound pressure level is observed at the vertical outlet monitoring point B, followed by the horizontal inlet monitoring point A, with the lowest at the horizontal outlet monitoring point C. At a constant flow velocity, the sound pressure level at the inlet and outlet points initially increases and then decreases as frequency increases.

Dual Monitoring with Stump Pressure and Electroencephalography During Carotid Endarterectomy

  • Chang, Jee Won;Kim, Su Wan;Lee, Seogjae;Lee, Jonggeun;Ku, Min Jung
    • Journal of Chest Surgery
    • /
    • 제50권2호
    • /
    • pp.94-98
    • /
    • 2017
  • Background: Intraoperative monitoring during carotid endarterectomy is crucial for cerebral protection. We investigated the results of carotid endarterectomy under dual monitoring with stump pressure and electroencephalography. Methods: We retrospectively reviewed the medical records of 50 patients who underwent carotid endarterectomy between March 2010 and February 2016. We inserted a temporary shunt if the stump pressure was lower than 35 mm Hg or if any intraoperative change was observed on electroencephalography. Results: Seventeen (34%) patients used a temporary shunt, and the mean stump pressure was 26.8 mm Hg in the shunt group and 46.5 mm Hg in the non-shunt group. No postoperative mortality or bleeding occurred. Postoperatively, there were 3 cases (6%) of minor stroke, all of which took place in the shunt group. A comparison of the preoperative and the intraoperative characteristics of the shunt group with those of the non-shunt group revealed no statistically significant difference between the 2 groups (p<0.01). Conclusion: Dual monitoring with stump pressure and electroencephalography was found to be a safe and reliable monitoring method with results comparable to those obtained using single monitoring. Further study should be performed to investigate the precise role of each monitoring method.

경수로 사용후핵연료 건식저장시스템의 격납감시 기술현황 분석 (Status Analysis for the Confinement Monitoring Technology of PWR Spent Nuclear Fuel Dry Storage System)

  • 백창열;조천형
    • 방사성폐기물학회지
    • /
    • 제14권1호
    • /
    • pp.35-44
    • /
    • 2016
  • Leading national R&D project to design a PWR spent nuclear fuel interim dry storage system that has been under development since mid-2009, which consists of a dual purpose metal cask and concrete storage cask. To ensure the safe operation of dry storage systems in foreign countries, major confinement monitoring techniques currently consist of pressure and temperature measurement. In the case of a dual purpose metal cask, a pressure sensor is installed in the interspace of bolted double lid(primary and secondary lid) in order to measure pressure. A concrete storage cask is a canister based system made of double/redundant welded lid to ensure confinement integrity. For this reason, confinement monitoring method is real time temperature measurement by thermocouple placed in the air flow(air intake and exit) of the concrete structure(over pack and module). The use of various monitoring technologies and operating experiences for the interim dry storage system over the last decades in foreign countries were analyzed. On the basis of the analysis above, development of the confinement monitoring technology that can be used optimally in our system will be available in the near future.

실시간 운전자 호흡 모니터링 (Real Time Driver's Respiration Monitoring)

  • 박재희;김재우;이재천
    • 센서학회지
    • /
    • 제23권2호
    • /
    • pp.142-147
    • /
    • 2014
  • Real time driver's respiration monitoring method for detecting driver's drowsiness is investigated. The sensor to obtain driver's respiration signal was a piezoelectric pressure sensor attached at the abdominal region of the seat belt. The resistance of the pressure sensor was changed according to the pressure applied to the seat belt due to the driver's respiration. Monitoring driver's respiration was carried out by driving on the virtual road in a driving simulator from Cheonan to Seoul and monitoring results were compared to the PELCLOS. Experiment results show that the driver's respiration signal can be used for detecting driver's drowsiness.

Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy

  • Kang, Seonghee;Choi, Chang Heon;Park, Jong Min;Chung, Jin-Beom;Eom, Keun-Yong;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.153-158
    • /
    • 2021
  • Purpose: This study evaluated the features of a pressure mapping system for patient motion monitoring in radiation therapy. Methods: The pressure mapping system includes an MS 9802 force sensing resistor (FSR) sensor with 2,304 force sensing nodes using 48 columns and 48 rows, controller, and control PC (personal computer). Radiation beam attenuation caused by pressure mapping sensor and signal perturbation by 6 and 10 mega voltage (MV) photon beam was evaluated. The maximum relative pressure value (mRPV), average relative pressure value (aRPV), the center of pressure (COP), and area of pressure distribution were obtained with/without radiation using the upper body of an anthropomorphic phantom for 30 minutes with 15 MV. Results: It was confirmed that the differences in attenuation induced by the FSR sensor for 6 and 10 MV photon beams were small. The differences in mRPV, aRPV, area of pressure distribution with/without radiation are about 0.6%, 1.2%, and 0.5%, respectively. The COP values with/without radiation were also similar. Conclusions: The characteristics of a pressure mapping system during radiation treatment were evaluated on the basis of attenuation and signal perturbation using radiation. The pressure distribution measured using the FSR sensor with little attenuation and signal perturbation by the MV photon beam would be helpful for patient motion monitoring.