• 제목/요약/키워드: Pressure Exchange

검색결과 386건 처리시간 0.026초

Effect of Columnar Structures on Exchange Anisotropy Field in Magnetoresistive NiO/NiFe Bilayers

  • Jai-Young Kim;Gyeong-Su Park;Jae-Chul Ro;Su-Jeong Suh
    • Journal of Magnetics
    • /
    • 제4권3호
    • /
    • pp.88-91
    • /
    • 1999
  • A series of NiO/NiFe bilayer films are deposited with the variation of Ar sputtering pressure for the NiO layers only. As the pressure for the NiO layers increases, the exchange anisotropy field (HEX) decreases gradually and becomes extinct at 2.5 mTorr, at which the maximum coercive force (HC) in the NiO/NiFe films is obtained. Randomly oriented columnar structures with HEX a few tens of Oe and oriented columnar structures with zero HEX are observed in the NiP layers by highvoltage hihg-resolution transmission electron microscopy. The vanishing of the HEX in the oriented structures is attributed to the lack of exchange anisotropy energy (EEX) between NiO and NiFe layers, which results in little contribution of interfacial unidirectional pinning anisotropy to the interface of NiO/NiFe bilayer.

  • PDF

고분자 전해질 연료전지의 전해질 막내의 함수율과 성능 예측 (Prediction of Fuel Cell Performance and Water Content in the Membrane of a Proton Exchange Membrane Fuel Cell)

  • 양장식;최경민;김덕줄
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.151-159
    • /
    • 2006
  • A one-dimensional numerical analysis is carried out to investigate the effects of inlet gas humidities, inlet gas pressures, and thicknesses of membrane on the performance of a proton exchange membrane fuel cell. It is found that the relative humidity of inlet gases at anode and cathode sides has a significant effect on the fuel cell performance. Especially, the desirable fuel cell performance occurs at low relative humidity of the cathode side and at high humidity of the anode side. In addition, an increase in the pressure ranging from 1 atm to 4 atm at the cathode side results in a significant improvement in the fuel cell performance due to the convection effect by a pressure gradient toward the anode side, and with decreasing the thickness of membrane, the fuel cell performance is enhanced reasonably.

압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교 (Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation)

  • 정성환;최원준;이정아;김진아;이문우;신형식;김미경;최강현
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.662-673
    • /
    • 1999
  • 연구배경 : Pressure-controlled ventilation(PCV)은 최근 호흡부전 환자에게서 자주 사용되는 환기방식이다. 이론적으로 PCV은 초기에 높은 기류를 제공하므로 volume-controlled ventilation(VCV)에 비해 최고흡기압이 낮고 가스교환에 이점이 있을 것으로 사료된다. 그러나 PCV에서 최고흡기압이 낮은 것에 대해서는 대부분의 보고가 일치하고 있으나 가스교환에 대해서는 상반된 결과를 보고하고 있다. 따라서 본 연구는 호흡부전 환자에서 PCV과 VCV간의 호흡역학과 가스교환의 비교 및 I : E ratio의 변동에 따른 차이가 있는지를 알아보고자 본 연구를 시행하였다. 방 법 : 호흡부전으로 기계호흡을 받고 있는 9명의 환자를 대상으로 하였다. 각 대상환자에서 흡기산소농도, 일회호흡용적, 호흡수 및 호기말양압은 변화시키지 않고, PCV와 VCV을 번갈아 적용하고 I : E ratio를 1 : 2, 1 : 1.3 및 1.7 : 1로 변화시키면서 기도압과 동맥혈 가스분석, 호기 이산화탄소 농도를 측정하여 PCV과 VCV 간의 호흡역학과 가스교환을 비교하였다. 결 과 : PCV과 VCV 모두에서 I : E ratio를 증가시킴에 따라 평균기도압이 증가하였고, $PaCO_2$와 생리적 사강이 감소하였다. 그러나 P(A-a)$O_2$는 변하지 않았다. 각각의 I : E ratio 모두에서 최고흡기압은 PCV시 더 낮았으며, 평균기도압은 PCV에서 더 높았다. 그러나 $PaCO_2$, 생리적 사강 및 P(A-a)$O_2$는 PCV과 VCV간의 차이를 보이지 않았다. 결 론 : 동일한 일회호흡용적, 호흡수 및 I : E ratio 상태에서는 두 환기 양식의 차이에 따른 가스교환의 차이가 없었다.

  • PDF

Impact of CO2 Emissions, Exchange Rate Regimes, and Political Stability on Currency Crises: Evidence from South Asian Countries

  • ULLLAH, Zia;FEN, Tan Xiao;TUNIO, Fayaz Hussain;ULLAH, Imran
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권2호
    • /
    • pp.29-36
    • /
    • 2022
  • This study uses the panel probit model to investigate and evaluate the relationship between exchange rate regimes, political stability, and carbon dioxide during currency crises. To understand currency crisis times, we study a panel dataset of seven South Asian nations that contain annual observations from 1996 to 2020. Furthermore, we created the EMPI exchange market pressure indicator to detect crises. Our results strongly suggested that fixed exchange rate is negatively associated with currency crises, with good regulatory quality and better effective governments. Simultaneously, the floating exchange rate is positively related to the currency crises in those countries where the rule of law has less adequately flowed. However, CO2, exports, and interest rates are buoyantly associated with crises. The floating exchange rate, the rule of law, exports, and interest rate are associated positively and contribute more prone to the crisis episodes. Negatively associated variables contributed less amid crises episodes: fixed exchange rate regime, government effectiveness, and regulatory quality. Meanwhile, CO2 has a positive relationship with a currency crisis and contributes more likelihood to the probability of a currency crisis. Countries that adopted the fixed exchange rates with effective governments and regulatory quality faced more minor currency crises.

2종류의 양말착의행동이 인체생리반응에 미치는 효과 (Effects of Two Kifferent Kinds of Socks on Physiologrical Responses)

  • 김희은;권오경
    • 한국의류학회지
    • /
    • 제23권2호
    • /
    • pp.242-249
    • /
    • 1999
  • The purpose of this study was to investigate two different kinds of socks on physiological responses at an ambient temperature of 35$\pm$1$^{\circ}C$ and relative humidity of 50$\pm$5% Five healthy women wearing normal socks or toes socks participated as the subjects. Rectal temperature skin temperatures sweat rate blood pressure pulse rate and questionnaire wee measured. Rectal temperature skin temperature sweat rate blood pressure pulse rate and questionnaire were measured. Rectal temperature and mean skin temperature were lower after exercise at wearing toes socks . Sweat rate was higher at wearing normal socks and blood pressure and pulse rate were tend to higher at wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks. Thermal comfort temperature sensation and humidity sensation were better wearing toes socks than wearing normal socks but wearing comfort was better at wearing normal socks. These results will be discussed form the viewpoint of thermoregulation AVA(Arterio venous Anastomosis) and count current heat exchange.

  • PDF

자본유출입 급변동과 외환 및 유통시장 안정성에 관한 연구 (A Study on the Sudden Stop in Capital Flows and Foreign Exchange and Distribution Market Stability)

  • 김윤철;이명훈
    • 유통과학연구
    • /
    • 제14권12호
    • /
    • pp.79-87
    • /
    • 2016
  • Purpose - Since 1990, the sudden stop in capital flows has caused the economic crisis. The purpose of this research is to suggest the policy measures to mitigate the risk of the sudden stop in capital flows. To this end, we examine the theoretical framework and analyze the case study for countries which are faced with the sudden stop. Also we examine the structural problems of the foreign exchange market in Korea and derive the policy implications to prevent the sudden stop. Research design, data, and methodology - The criteria of whether the sudden stop in capital flows occurs are based upon Calvo et al. (2008). In case the proxy variable for the balance of capital account decreases from the average by over twice standard deviation, we determine that the sudden stop occurs for that country. The sample period is from January 1990 to December 2008, as in Calvo (2014). The sample countries are 17 developed countries and 19 emerging market countries, which are different from those of the previous papers as Agosin and Huaita (2012), and Calvo (2014). When the exchange market pressure index(EMPI) is deviated from the average by over three times standard deviation, we determine that the foreign exchange market is unstable for that country. Results - We find that the characteristics of the sudden stop in capital flows are the bunching or contagion among countries, the rapid drop in real effective exchange rate, and the huge decrease in foreign exchange reserves. Many countries tried to increase foreign exchange reserves and regulate capital flows. Also the foreign exchange market in Korea are found to be the volatile exchange rate, the vulnerable external debt and careless management of the foreign exchange derivatives transaction risk. Conclusions - To lessen the risk in the sudden stop of capital flows, this research suggests the some useful policy measures. To enhance the foreign exchange and distribution market stability, we should improve the price mechanism of exchange rate, hold the appropriate level of foreign exchange reserves, prevent excessive inflows of foreign exchange and promote sound transactions of foreign exchange derivatives.

Exports of SMEs against Risk? Theory and Evidence from Foreign Exchange Risk Insurance Schemes in Korea

  • Lee, Seo-Young
    • Journal of Korea Trade
    • /
    • 제23권5호
    • /
    • pp.87-101
    • /
    • 2019
  • Purpose - This paper examines the effectiveness of the foreign exchange risk insurance system in the promotion of SME exports in Korea. The purpose of this study is to analyze the short-term and long-term responses of SME exports to foreign exchange risk insurance support policies. Based on these empirical studies, we would like to present some operational improvements to the operation of the foreign exchange risk insurance system. Design/methodology - In order to analyze the effect of exchange risk insurance on the exports of SMEs, a VAR model consisting of foreign exchange risk insurance underwriting values, export relative price, and domestic demand pressure, including export volume, was established. The study began with tests of the stationarity of time series data. The unit root tests showed that all concerned variables were non-stationary. Accordingly, the results of the cointegration test showed that the tested variables are not cointegrated. Finally, an impulse response function and variance decomposition analysis were conducted to analyze the impulse of foreign exchange risk insurance on exports of SMEs. Findings - As a result of estimating the VAR (1) model, foreign exchange risk insurance was found to be significant at a 1% significance level for SME' export promotion. In the impulse response analysis, SMEs' export response to the impulse of foreign exchange risk insurance showed that exports gradually increased until the third quarter, and then slowed down. However, the impulse did not disappear, and appeared continuously. Originality/value - This study analyzed the effect of foreign exchange insurance on exports of SMEs by applying the VAR model. In particular, this study is the first to analyze the short-term and long-term effects of foreign exchange risk insurance on exports of SMEs. The empirical evidence in the current study have a policy implication for the policy authority to support and promote the foreign exchange risk insurance in the effect of exchange rate volatility on Korea' export SMEs.

Structure and Magnetic Properties of Cr2O3/CrO2 Nanoparticles Prepared by Reactive Laser Ablation and Oxidation under High Pressure of Oxygen

  • Si, P.Z.;Wang, X.L.;Xiao, X.F.;Chen, H.J.;Liu, X.Y.;Jiang, L.;Liu, J.J.;Jiao, Z.W.;Ge, H.L.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.211-214
    • /
    • 2015
  • $Cr_2O_3$ nanoparticles were prepared via one-step reactive laser ablation of Cr in oxygen. The metastable $CrO_2$ phase was obtained through the subsequent oxidation of $Cr_2O_3$ nanoparticles under $O_2$ with gas pressures of up to 40 MPa. The as-prepared $Cr_2O_3$ nanoparticles are spherical or rectangular in shape with sizes ranging from 20 nm to 50 nm. High oxygen pressure annealing is effective in producing meta-stable $CrO_2$ from as-dried $Cr_2O_3$ nanoparticles, and the $Cr_2O_3$ nanoparticles exhibit a weak ferromagnetic behavior with an exchange bias of up to 11 mT that can be ascribed to the interfacial exchange coupling between uncompensated surface spins and the antiferromagnetic core. The $Cr_2O_3/CrO_2$ nanoparticles exhibit an enhanced saturation magnetization and a reduced exchange bias with an increasing faction of $CrO_2$ due to the elimination of uncompensated surface spins over the $Cr_2O_3$ nanoparticles when exposed to a high pressure of $O_2$ and/or possible phase segregation that results in a smaller grain size for both $Cr_2O_3$ and $CrO_2$.

Membrane fouling control in low pressure membranes: A review on pretreatment techniques for fouling abatement

  • Arhin, Samuel Gyebi;Banadda, Noble;Komakech, Allan John;Kabenge, Isa;Wanyama, Joshua
    • Environmental Engineering Research
    • /
    • 제21권2호
    • /
    • pp.109-120
    • /
    • 2016
  • Conventional treatment techniques cannot meet the stringent modern water quality regulations emanating from the need to provide high quality drinking water. Therefore, a number of studies have suggested low pressure membrane filtration as a worthwhile alternative. However, a major constraint to the extensive use of this technology in low and middle income countries is the high operating and maintenance costs caused by the inherent predisposition to membrane fouling. Notwithstanding, pretreatment of feed water using techniques such as coagulation, adsorption, oxidation and bio-filtration is believed to control fouling. In this review paper, the existing scientific knowledge on membrane fouling and pretreatment techniques for controlling fouling in low pressure membranes is analyzed with the aim of providing new and valuable insights into such techniques, as well as unveiling crucial issues noteworthy for further studies. Among the techniques reviewed, coagulation was observed to be the most cost-effective and will remain the most dominant in the coming years. Although oxidants and magnetic ion exchange resins can also control fouling, the propensity of oxidants to form health treating precursors and the high economic implications of magnetic ion exchange resins will hinder their adoption in developing countries.

동일 전열면적을 갖는 용접식 판형열교환기와 관류형 열교환기의 성능 비교 (Performance Comparison of a Welded Plate Heat Exchanger and Shell and Tube Heat Exchanger with Same Heat Transfer Area)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.46-54
    • /
    • 2019
  • In this study, the performance of a shell and tube heat exchanger (STHE) and welded plate heat exchanger (WPHE) was measured experimentally. The pass numbers of the STHE was changed by 1, 2 and 4. As a result, the WPHE showed 2.1 times higher heat exchange capacity than that of the STHE. In case of pressure drop, the STHE with 1 and 2 pass number has a lower pressure drop than the WPHE, while the STHE with 4 pass presented higher pressure drop than the WPHE. The performance index considering the heat exchange capacity and pump consumption power, showed in oder of STHEPass1 > STHEPass2 > W PHE > STHEPass4 under the same flow rate. Therefore, when the WPHE was designed optimally under same operating condition with STHE, the maintenance fee and space can be reduced effectively by using the WPHE.