• Title/Summary/Keyword: Pressure Difference

Search Result 3,930, Processing Time 0.035 seconds

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

Effects of foot pressure using the elastic band with rings during sit-to-stand in persons with stroke

  • Hwang, Young-In;Kim, Ki-Song
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.4
    • /
    • pp.159-163
    • /
    • 2017
  • Objective: Persons with stroke have a tendency to exhibit asymmetric weight-bearing during sit-to-stand because due to the attempt to support themselves with the non-paretic foot. However, there are few devices that can assist with sit-to-stand (STS) performance. This study was designed to investigate the use of the elastic band with rings (EBR) in improving weight-bearing effectively in persons with stroke during STS training. Design: Cross-sectional study. Methods: Thirteen stroke survivors participated in the study. An EBR was applied onto the patient during STS activity. The foot pressure was measured before and after wearing the EBR, with a 5-minute rest period between measurements. Subjects were asked to perform each test twice with and without the EBR. Bilateral feet pressures were measured with standing posture being divided into the forward and backward aspects. The foot contact pressure during STS activity was measured with the CONFORMat System. Results: With EBR, the forward pressure of the affected foot significantly increased while the less-affected forward foot pressure significantly decreased (p=0.015 and p=0.023, respectively). The backward foot pressure did not differ significantly in the two limbs, and there was no difference with and without the EBR in terms of the total pressure of the affected foot. There was a significant difference with and without the EBR in the total pressure of the less-affected foot (p<0.05). Conclusions: STS training with the EBR has been shown to improve weight-bearing of both feet while decreasing the total pressure of the less-affected foot in stroke survivors. Therefore, we suggest that the EBR is a useful tool for STS training for persons with stroke in the clinic.

Failure Probability Estimation of Flaw in CANDU Pressure Tube Considering the Dimensional Change (가동중 중수로 압력관의 외경과 두꼐 변화를 고려한 결함의 파손확률 예측)

  • Kwak, Sang-Log;Lee, Joon-Seong;Kim, Young-Jin;Park, Youn-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2305-2311
    • /
    • 2002
  • The pressure tube is a major component of the CANDU reactor, which supports nuclear fuel bundle and heavy water coolant. Pressure tubes are installed horizontally inside the reactor and only selected samples are periodically examined during in-service inspection. In this respect, a probabilistic safety assessment method is more appropriate fur the assessment of overall pressure tube safety. The failure behavior of CANDU pressure tubes, however, is governed by delayed hydride cracking which is the major difference from pipings and reactor pressure vessels. Since the delayed hydride cracking has more widely distributed governing parameters, it is impossible to apply a general PFM methodology directly. In this paper, a PFM methodology for the safety assessment of CANDU pressure tubes is introduced by applying Monte Carlo simulation in determining failure probability Initial hydrogen concentration, flaw shape and depth, axial and radial crack growth rate and fracture toughness were considered as probabilistic variables. Parametric study has been done under the base of pressure tube dimension and hydride precipitation temperature in calculating failure probability. Unstable fracture and plastic collapse are used for the failure assessment. The estimated failure probability showed about three-order difference with changing dimensions of pressure tube.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

Pressure Loss Analysis of the 75 kW MCFC Stack with Internal Manifold Separator (75 kW 용융탄산염 연료전지 (MCFC) 스택 내 압력 손실 해석)

  • Kim, Beom-Joo;Lee, Jung-Hyun;Kim, Do-Hyeong;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.367-376
    • /
    • 2008
  • To obtain the data of the pressure loss and differential pressure at the inside of the stack that was composed of 126 cells with 7,500 cm2 electrode area, 75kW molten carbonate fuel cell system has been operated. Computational fluid dynamics was applied to estimate reactions and thermal fluid behavior inside of the stack that was adopted with internal manifold type separator. The pressure loss coefficient K showed 72.29 to 84.01 in anode and 6.34 to 8.75 in cathode at low part of cells at the inside of 75 kW MCFC stack respectively. Meanwhile, the pressure loss coefficient of the higher part of cells at the interior of the stack showed 15.36 and 56.44 in anode and cathode respectively. These results mean that there is no big total pressure difference between anode and cathode at the inner part of 75 kW MCFC stack. This result will be reflected in 250kW MCFC system design.

Numerical Studies on the Effects of the Channel-Inlet-Pressure Difference in the Pressure-Retarded Osmosis (PRO) Power System (압력지연삼투(PRO) 발전 시스템에서 채널 입구 압력차의 영향에 대한 수치해석적 연구)

  • Hong, Sung Soo;Ryoo, Won;Chun, Myung-Suk;Chung, Gui Yung
    • Korean Chemical Engineering Research
    • /
    • v.52 no.1
    • /
    • pp.68-74
    • /
    • 2014
  • In the spiral wound module of the pressure-retarded osmosis (PRO) system for the salinity gradient power generation, effects of the inlet pressure differences between feed-channel and draw-channel were studied. Fluxes of water and solute through membrane and power were estimated. The water flux through membrane decreased along the x-direction and increased along the y-direction with the increase of inlet pressure differences between two channels. On the other hand, the solute flux through membrane showed the opposite trend. The concentration of flow in the feed-channel increased a lot along the y-direction and that in the draw-channel decreased along the x-direction. In our system, for the inlet pressure differences of 1~11 atm, the flow rate in the feed-channel decreased about 8~13% and that in the draw-channel increased by the same amount. The power density increased and then decreased with the increasing inlet pressure difference.

The Effect of the Wedge Insole Angle of Supinated Group on Foot Contact Time, Foot Contact Area and Foot Pressure (회외족의 Wedge Insole 각에 따른 보행 시 접지 시간, 접지면적 및 족저압력의 비교)

  • Lee, Hyo-Taek;Kim, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.22 no.4
    • /
    • pp.508-515
    • /
    • 2010
  • This study was conducted on male college students with supinated foot to measure the foot pressure by having them wear three kinds of wedge insoles ($0^{\circ}$, $3.5^{\circ}$, $7^{\circ}$). Foot contact time, foot contact area, peak pressure and mean pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding foot contact time, there was no statistically significant difference by showing $0.69{\pm}0.004$ seconds at $3.5^{\circ}$ and $0.68{\pm}0.006$ seconds at $0^{\circ}$ and $7^{\circ}$. Regarding the foot contact area, it appeared broad in the inside area of the foot according to wedge insole, and there was statistically significant difference in the area 1 of the rear foot(p< .01) and the area 3 of the middle foot(p< .05). The peak pressure by foot area decreased in the outside of the foot according to wedge insole, while increasing in the inside of the foot. Among the areas, there was statistically significant in the area 2 of the rear foot (p< .01) and the area 3 of the middle foot (p< .05). Regarding the mean pressure by foot area, the pressure roughly increased in the inside area of the foot according to wedge insole, while decreasing in the outside of the foot.

Comparative Evaluation of Jacket for Middle-aged Women according to Clothing Pressure Analysis (의복압 분석에 따른 중년 여성의 재킷비교평가 연구)

  • 이영숙;박은주;서추연
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.485-495
    • /
    • 2003
  • This study was to compare and analyze the clothing pressure according to arms movements of 4 brands jacket for middle-aged women group by measuring clothing pressure of each brand. The results were as follows: 1. According to the analysis of jackets of 4 brands, in general, jacket C had the largest ease amount. while jacket A had a large ease amount in waist, hip areas compared with bust area. Also jacket B had a small ease amount in bust, waist areas and jacket D had a small ease amount in hip areas. Therefore the ease amount is different between each brand, each size even though jacket designs are similar. 2. It was found that clothing pressure was affected by arm movements than jackets. Since this study was limited to the arm movement for motion variation, it was recognized that a significant difference among each jacket and each movement at shoulder, waist parts existed with relation to this motion. 3. Parts showing a significant difference among each size were bust point, abdomen point, center back point of abdomen level, angulus superior scapulae point and center back point of waist level. Also clothing pressure of size B91 was bigger than size B88 except Center back point of waist level. 4. Clothing pressure in shoulder point, front armpit point, back armpit point, upper arm point areas increased as the angle of the arms movement increased. Also, individual variation of clothing pressure in front armpit point, back armpit point, armpit point and upper arm point was large, and clothing pressure in abdomen point was high in M5(sitting posture).

Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms (긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가)

  • Shin, Hee Won;Kim, Dong Wook;Kim, Ji Min;Jung, Hyo Beom;Kang, Dong Hwa
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.

A Study on the Pressure of the Korean Skirt Band (한복 치마허리의 압력에 관한 연구)

  • Rhyu Hee-Sook;Rhie Jeon-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.2 s.30
    • /
    • pp.103-108
    • /
    • 1989
  • The purpose of this study was to confirm the difference of garment pressure and comfort depend on age group wearing the Korean skirt-band. A loadcell was used for measuring garment pressure, and 25 female subjects were chosen for each of young, middle, and old age groups. Garment pressure was measured in front, side, and back parts of the body. The results were as follows: 1. The younger the subjects, the greater the garment pressure. This suggests that the young age group wear the Korean skirt-band more tightly than needed. 2. The measurements of the pressure in 3 parts of the body were different. In young and middle age groups, pressure decreased from side to back, while in the old age group the order was side, back, and (rent. 3. The young age group felt high restriction of pressure. And the pressure in side part of body is the greatest among the three measurement.

  • PDF