• Title/Summary/Keyword: Pressure Control

Search Result 6,066, Processing Time 0.033 seconds

A Study on the Pressure Control of a Pneumatic Pressure Vessel Considering Dynamic Characteristics of Pneumatic Transmission Line (관로부의 동특성을 고려한 공기압 압력용기의 압력제어)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.90-96
    • /
    • 2001
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel considering dynamic characteristics of pneumatic transmission line is proposed. Dynamic characteristics of transmission line using compressible fluid is changed by the flowing states of the fluid. So, if the fixed gain controller is designed based on a fixed model, the performance of the control system could be destabilized or degraded. The controller designed in this study is composed of two parts. The one is to reject modelling error based on the disturbance observer, the other is to obtain the control performance. The control results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of the pressure control system using compressible fluid such as air and gas

  • PDF

Design of Back Pressure Control Valve for Automotive Scroll Compressor (차량용 전동식 스크롤 압축기의 배압제어밸브 설계)

  • Nam, Bo-Young;Koo, In-Hwe;Han, Young-Chang;Lee, Geon-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.410-415
    • /
    • 2007
  • The optimization of back pressure chamber is one of the most important factors in designing scroll compressors, because it has a great influence on the efficiencies and other design parameters. The design process can be divided into 2 parts. One is obtaining the optimum pressure of the chamber and keeping it in constant value. And the other is finding out the minimum inflow rate of medium with which back pressure chamber is filled. In this study we are focused on the first step. At first we added a simple structure that could change back pressure without reassembling compressor. It makes the optimum back pressure be obtained. And then we devised an equipment that the back pressure control valve assembly could be independently tested with. A spring was redesigned to decrease stiffness variation. And sealing mechanism of back pressure control valve was improved to more effective way. As a result it was verified in a real mode test that back pressure variation could be stabilized within 2.3% when discharge pressure and operating frequency varied. And the integrated structure of back pressure control valve is expected to contribute to an effective manufacturing process.

  • PDF

A Study on the Pressure Control Characteristics of ON/OFF 3-way Solenoid Valve Driven by PWM Signal (개폐식 3방향 전자밸브의 펄스폭 변조 구동에 의한 압력제어 특성에 관한 연구)

  • Jeong, Heon-Sul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.485-501
    • /
    • 1997
  • Pressure control is possible driving a simple ON/OFF 3-way valve of hydraulic servo system by pulse width modulation signal. But the pressure varies according to the duty ratio and carrier frequency and repeated on-off action induces pressure fluctuation. So equations for mean pressure and ripple amplitude are theoretically derived as a function of on/off time, the system parameters which decide the pressure characteristics are arranged and they are verified by experimental study. As the result selection criteria for the major design parameters are established and the basic strategy to suppress the unnecessary fluctuation can be provided for a hydraulic pressure control system using these type of valves.

Experimental Study on the PWM Pressure Control Characteristics of 2 Way Solenoid Valve (2방향 전자밸브 PWM압력제어특성의 실험적 비교연구)

  • 정헌술;박성진;김창완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.107-111
    • /
    • 1997
  • Pressure control is possible by pulse width modulation signal driving a simple ON/OFF 2-way valve of hydraulic servo system. But it indices pressure fluctuation due to repeated on-off action and the pressure varies according to the duty ratio and carrier frequency. So mean pressure and ripple amplitude are arranged by experimental study as the driving signal change which decides the pressure characteristics. As the result selection criteria of the major design parameters may be established and the basic strategy to suppress the unnecessary flucturion may be provided for a hydraulic pressure control system.

  • PDF

Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal (2방향 전자밸브의 PWM 신호에 의한 압력제어 특성)

  • Jeong, Heon-Sul;Kim, Hyoung-Eui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

Nonlinear adaptive control for multivariable system

  • Song, Sukheung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.60.4-60
    • /
    • 2002
  • Nonlinear adaptive control for the laboratory pressure-flow model. Control valves are installed on both sides. The pressure and the outlet flow rate are measured. The pressure and outlet flow rate are controlled variables and the control valve stem positions on both sides are the manipulated variables. The variation in both inputs will influence both controlled variables. The control performance is good, in spite of varying valve coefficients of inlet and outlet.

  • PDF

Pressure Control of SR Driven Hydraulic Oil-Pump Using Data based PID Controller

  • Lee, Dong-Hee;Kim, Tae-Hyoung;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.800-808
    • /
    • 2009
  • This paper presents a practical method of pressure control for a hydraulic oil-pump system using an SR (Switched Reluctance) drive. For a 6Mpa grade hydraulic oil-pump, a 2.6kW SR drive is developed. In order to get high performance pressure dynamics in actual applications, a data based PID control scheme is proposed. The look-up table from a pre-measured data base produces an approximate current reference based on motor speed and oil-pressure. A PID controller can compensate for the pressure error. With the combination of the two references, the proposed control scheme can achieve fast dynamics and stable operation. Furthermore, a suitable current controller considering the nonlinear characteristics of an SRM (Switched Reluctance Motor) and practical test methods for data measuring are presented. The proposed control scheme is verified by experimental tests.

Control Methods of the VAV Air Handling Unit for the Required Outdoor Air Demand (변풍량 공조시스템의 요구외기량 확보를 위한 제어방식)

  • Han, Do-Young;Joo, Young-Duk;Kim, Jin;Lee, Jun-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.203-209
    • /
    • 2003
  • Control algorithms of an air handling unit by using the mixing box plenum pressures were developed and verified by experiments. Control algorithms developed for this study were the setpoint algorithms for the outdoor damper position, the outdoor/fixed plenum pressure, and the return/exhaust plenum pressure. The outdoor/fixed plenum pressure setpoint was used to control the bypass damper position, and the return/exhaust plenum pressure setpoint was used to control the return fan speed. Experimental results showed the good control of the required outdoor air demand. Therefore, setpoint algorithms developed for this study may effectively be applied for the control of the VAV air handling unit.

A Study on the Prevalence Rate of Hypertension and the Actual Conditions of Control (일 지역 성인의 고혈압 유병률 및 관리 실태)

  • Kim, Hyeon-Ok
    • Research in Community and Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.154-172
    • /
    • 1999
  • In order to analyse the prevalence rate of hypertension and the actual conditions of control, we selected five districts out of eleven eups and myuns in Chinan Country. We administered structured questionaries to 309 adults above the age of 40, computerized the data using SPSS - PC+. More than 40.1% of adults over 40 in Chinan County have health disorders ranging from high blood pressure to hypertension including alert high blood pressure at 36.2%, relatively high. Among general characteristics, differences in the rate of hypertension were influenced by age, occupation and places of residence. Over 71 who are engaged in agriculture, who don't have jobs, who reside in Sungsu, Jungchun, Chinan-eup all have higher hypertension rates than other groups. Accordingly, the control of hypertension should be focused on these people. As a result of the control of blood pressure, the survey showed 93.0% of the subjects were checked mainly at hospitals clinics, health centers subhealth centers and community health posts more than once a year, relatively high level of blood pressure management. However, the difference between their blood pressure measurements at ordinary times and the level of blood pressure at the time of research was quite considerable. Only 47.3% of the subjects diagnosed with high blood pressure and 70.3% of the subjects with normal blood pressure recognized their blood pressure accurately 52.7% of the subjects diagnosed with high blood pressure showed errors in understanding their blood pressure at normal times. Because these errors can cause problems in the control of blood pressure, proper management should be executed through a systematic examination. As a result of the high blood pressure control condition, the average period of hypertension was 74.5( ${\pm}92.8$) months, 92.3% of the subjects were diagnosed with high blood pressure at hospitals clinics, health centers subhealth centers community health posts, but only 29.5% were examined after a general check up on high blood pressure was completed. 70.5% were diagnosed with high blood pressure only after measuring their blood pressure. 14.1% of the subjects were hospitalized because of falls influenced by high blood pressure. 33.3% attended hospitals and health centers regularily for medical treatment and this shows how low the rate of the control of blood pressure. Most people did not undergo medical treatment, because they had no painful symptoms (46.7%), they didn't need to take the medicine(28.9%), or they forget to take the medicine(20.0%). These problems in the control of hypertension were discovered in the process of diagnosing high blood pressure at health medical institutions. Many people did not recognize the need for consistent control of blood pressure. That is, although the diagnosis for high blood pressures performed at hospitals clinics, health centers subhealth centers and community health posts, was 92.3%, more than 70.5% of the subjects were not examined completely with regard to blood pressure. Accordingly, heath medical institutions must diagnose high blood pressure not only by only measuring blood pressure but also by using systematic process of examination. As for the people diagnosed with high blood pressure, one should perform consistent medical approaches and help them to recognize the importance of the continuous control of blood pressure through subject-oriented education. Problems the subjects experienced were the following numbness in the limbs easily paralyzed stitches in their shoulders which felt painful, stiff necks, occiputs felt heavy, headaches when they got up in the morning, felt dizzy when standing and moving their heads and poor eyesight. The rate of knowledge related to high blood pressure was 78.7 points, comparatively low. Whether they had normal blood pressure or hypertension made no difference. These results are not desirable. Adult-oriented education forgot the prevention and management of high blood pressure should be implemented. Hypertensive-oriented education should be especially reinforced. Because there was a difference in the level of knowledge according to age, academic career, occupation or place of residence, education related to hypertension should be intensified and focused on those over the age of 71 those who did not attend school, those who do not have jobs and are engaged in agriculture and residents living in Bugui, Jungchun regions. The degree of healthy life practice in hypertensives is poor, particularly weight control, as opposed to people who have normal blood pressure. It makes no difference in smoking, the amount of daily smoking, drinking, the control of salt because each result means that they are not practicing healthy life or modifying their life-style. The development and programs to improve a healthy life should be executed.

  • PDF

Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses (저압 에어포그 시스템을 설치한 온실의 냉방효율)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo;Ko, Gi-Hyuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.