• Title/Summary/Keyword: Presence Sensor

검색결과 301건 처리시간 0.031초

$SnO_2$ 소결체 반도체 Gas Sensor에 관한 연구 (On the $SnO_2$ Semiconductor Gas Sensor)

  • 박순자;이재열
    • 한국세라믹학회지
    • /
    • 제20권2호
    • /
    • pp.93-98
    • /
    • 1983
  • The sensitivity characteristics of $SnO_2$-based gas sensor prepared by sintering method have been studied at the presence of CO and Propane gas. Samples mixed with 1wt% $La_2O_3$ and 1wt% $PdCl_2$ showed highest sensitivity to CO and propane gas at 250$^{\circ}$C but the addition of $CeO_2$ did not enhance the sensitivity. For slectivity for gas a $SnO_2-La_2O_3$ (1wt%) sample without $PdCl_2$ showed better results. A sample sintered sintered at 115$0^{\circ}C$ has shown the optimum condition in sensitivity and electroding

  • PDF

SDINS에서 의사 자이로 바이어스 보상 기법 (Compensation of Pseudo Gyro Bias in SDINS)

  • 박정민
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제13권2호
    • /
    • pp.179-187
    • /
    • 2024
  • The performance of a Strapdown Inertial Navigation System (SDINS) relies heavily on the accuracy of sensor error calibration. Systematic calibration is usually employed when only a 2-axis turntable is available. For systematic calibration, the body frame is commonly defined with respect to sensor axes for ease of computation. The drawback of this approach is that sensor axes may undergo time-varying deflection under temperature change, causing pseudo gyro bias. The effect of pseudo gyro bias on navigation performance is negligible for low grade navigation systems. However, for higher grade systems undergoing rapid temperature change, the error is no longer negligible. This paper describes in detail conditions leading to the presence of pseudo gyro bias, and proposes two techniques for mitigating the error. Experimental results show that applying these techniques improves navigation performance for precision SDINS, especially under rapid temperature change.

다양한 센서 신호를 이용한 복합적층판의 고속충격 손상 특성 연구 (Study on the Damage Characteristics Under the High-Velocity Impact of Composite Laminates Using Various Sensor Signals)

  • 조상규;김인걸;이석제;유원영
    • Composites Research
    • /
    • 제24권6호
    • /
    • pp.49-55
    • /
    • 2011
  • 복합재는 금속보다 높은 비강성과 비강도를 갖는 장점 때문에 군용기와 민항기의 주요 구조물로 사용이 증대되고 있다. 하지만 복합재의 기계적인 특성은 충격에 의해 심각하게 저하된다. 특히, 우박, 고속 택싱에 의한 파편과의 고속 충격은 작은 질량임에도 불구하고 구조물과 서브시스템에 심각한 손상을 줄 수 있다. 그러나 한 가지 센서 또는 기존의 기법을 사용하여 복합재의 손상을 탐지하기는 쉽지 않다. 본 논문에서는 복합적층판의 고속충격에 의한 손상 개시와 전파를 모니터링하기 위해 PVDF 센서와 AE 센서를 사용하였다. 센서 신호를 분석하기 위해 웨이블릿 변환을 사용하였다. 충격에너지가 증가할수록 고주파 신호가 증가하였고 PVDF 센서와 AE 센서 신호에서 유사한 경향을 알 수 있었다. 결과적으로 복합적층판의 고속충격손상을 감지하고 특성화하는 다양한 센싱 기법을 제시하였다.

에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구 (A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator)

  • 최철광;이전선;김정태;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

유비쿼터스 센서네트워크를 위한 퍼지시스템 기반 적응형 센싱 (Adaptive Sensing based on Fuzzy System for Ubiquitous Sensor Networks)

  • 마테오로미오;이재완
    • 인터넷정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.51-58
    • /
    • 2008
  • 무선 센서네트워크는 효율적인 자료처리 및 유비쿼터스 시스템 구현을 위해 여러 응용에서 사용되고 있다. 그러나 무선센서네트워크에 기반 한 최근 주차관리시스템 연구에서는 적응형 센싱이나 효율적인 자료처리 기법은 거의 고려되지 않고 있다. 주차관리응용에서의 성능은 이러한 분산된 컴퓨팅장비들의 효율적인 구현에 영향을 받는다. 이 논문은 주차관리 유비쿼터스 네트워크 시스템을 위해 퍼지 무선센서를 이용한 적응형 센싱기법을 제시한다. 효율적인 주차탐색을 위해 퍼지추론시스템이 센서에 탑재된다. 또한 자동차 주차공간의 환경변화에 적응을 위해 새로운 갈을 각 센서에 무선으로 전송하는 규칙기반 적응형 모듈을 제시한다. 실험결과 제안한 퍼지기반 무선센서가 일반적인 무선센서에 의해 수집하는 방법에 비해 우수한 처리율과 적은 지연시간을 보였다.

  • PDF

산성 용액의 pH를 감지할 수 있는 형광 센서막 (A Fluorescent Sensor Film for Detecting pH of Acidic Solutions)

  • 민재영;김형진
    • 대한화학회지
    • /
    • 제64권2호
    • /
    • pp.74-78
    • /
    • 2020
  • 산성 영역에서 작동하는 고감도 형광 pH 센서막을 제조하기 위하여 실란화된 유리 표면 상에 push-pull 공액 염료(DCMP)를 공유결합에 의해 고정화하였다. DCMP 유도체(DCMA), 2-hydroxyethyl methacrylate (HEMA)및 triethylene glycol dimethacrylate의 혼합물을 광개시 공중합하여 pH 감응성 형광센서막을 제조하였다. 분광학적 측정 결과, pH 2.0-5.0 사이에서 pH가 증가함에 따라 센서막의 흡광도가 증가하였으며, 같은 pH 범위에서 pH 증가에 따라 센서막의 형광 세기도 약 50배 정도 증가하였다. 산성 조건에서 pH 변화에 대한 센서막의 감응은 가역적이고 재현성이 우수하였다. 또한 센서막은 20-50초 사이의 비교적 짧은 감응 시간과 여러 금속이온 존재에서 수소 이온에 대해 높은 선택성을 나타내었다.

A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

  • Abbas, Mohammad Nooredeen;Amer, Hend Samy
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1153-1159
    • /
    • 2013
  • A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from $3{\times}10^{-7}$ to $1{\times}10^{-2}$ M and a lower detection limit (LDL) of $1{\times}10^{-7}$ M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.

SIP 프레즌스 모델 기반 센서 태그의 상태이력 추적 (Tracking and Tracing the Status Changes of Sensor Tags based on the SIP Presence Model)

  • 김동욱;홍진표
    • 한국정보과학회논문지:정보통신
    • /
    • 제36권3호
    • /
    • pp.231-242
    • /
    • 2009
  • RFID객체 이력추적기술은 EPCglobal에서 제안하는 Discovery Service를 중심으로 다수의 연구가 진행 중이다. 하지만 객체의 상태변화를 모니터링 하는 기능을 제공하지 않으며, 객체의 이력정보를 특정 서버에서 취합하여 관리해야 한다는 단점이 있다. 이 문제를 해결하기 위해서는 객체에 대한 상태정보를 제공하기 위한 모델이 필요하며 RFID 객체의 URL을 나타낼 수 있는 식별자 역시 필요하다. 이러한 문제점을 보완하고자 SIP 이벤트 통지 및 프레즌스 모델을 활용하여 RFID 객체의 상태정보를 Track & Trace하기 위한 새로운 방법을 제안한다. 본 논문에서는 객체의 URL을 얻기 위해서 기존 ONS를 그대로 활용하되 성능저하가 없도록 하여 backward-Compatibility를 충족하도록 하였다. 또한 이렇게 얻어진 URL을 이용하여 RFID 객체 혹은 객체의 상태정보를 관리하고 있는 요소에 접근하기 위해 SIP 프로토콜을 사용하도록 하여 객체관리를 위해 개방형 인터페이스를 사용하였다. SIP 메시지 조합을 통해 객체의 이력정보를 얻을 때 DS와 같은 추가적 요소 없이도 객체의 Track을 Trace가 가능하게 하였다. 이 방식을 활용하여 지금까지와는 달리 분산취합구조를 이용하여 객체에 대한 상세이력정보 및 모니터링을 제공할 수 있도록 하였다.

고 선량율 감마선 조사에 따른 렌즈의 열화 (A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation)

  • 조재완;이준구;허섭;구인수;홍석붕
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

A Chemiluminescence Method for the Determination of Ascorbic Acid based upon Its Reaction with Cerium(IV) in the Presence of $Ru(bipy)_3^{2+}$

  • Lee, Sang-Hak;Bae, Hyun-Sook;karim, Mohammad-Mainul;Kim, Chang-Jin;Kim, Young-Sun;Lee, Hyun-Sook;Hong, Sang-Beom
    • Journal of Photoscience
    • /
    • 제12권3호
    • /
    • pp.149-153
    • /
    • 2005
  • A chemiluminescence (CL) method for the determination of ascorbic acid was proposed, which is based on the enhancement of the CL intensity of $Ru(bipy)_3^{2+}$ - Ce (IV) system with the addition of ascorbic acid. The CL intensity is proportional to the concentration of ascorbic acid in the range of $1{\times}10^{-10}\;to\;1{\times}10^{-5}M$ with a correlation coefficient of 0.9985. The detection limit is $3{\times}10^{-11}M$. The relative standard deviation (R.S.D.) of 10 determinations of 0.1 mM ascorbic acid was 1.75%. The proposed method has been successfully applied to the determination of ascorbic acid in the commercia] drinks. The possible mechanism of the CL reaction was studied.

  • PDF