• Title/Summary/Keyword: Premature contraction

Search Result 59, Processing Time 0.025 seconds

Detection of QRS Feature Based on Phase Transition Tracking for Premature Ventricular Contraction Classification (조기심실수축 분류를 위한 위상 변이 추적 기반의 QRS 특징점 검출)

  • Cho, Ik-sung;Yoon, Jeong-oh;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.427-436
    • /
    • 2016
  • In general, QRS duration represent a distance of Q start and S end point. However, since criteria of QRS duration are vague and Q, S point is not detected accurately, arrhythmia classification performance can be reduced. In this paper, we propose extraction of Q, S start and end point RS feature based on phase transition tracking method after we detected R wave that is large peak of electrocardiogram(ECG) signal. For this purpose, we detected R wave, from noise-free ECG signal through the preprocessing method. Also, we classified QRS pattern through differentiation value of ECG signal and extracted Q, S start and end point by tracking direction and count of phase based on R wave. The performance of R wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 99.60%. PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30 premature ventricular contraction(PVC). The achieved scores indicate the average detection rate of 94.12% in PVC.

An SPC-Based Forward-Backward Algorithm for Arrhythmic Beat Detection and Classification

  • Jiang, Bernard C.;Yang, Wen-Hung;Yang, Chi-Yu
    • Industrial Engineering and Management Systems
    • /
    • v.12 no.4
    • /
    • pp.380-388
    • /
    • 2013
  • Large variation in electrocardiogram (ECG) waveforms continues to present challenges in defining R-wave locations in ECG signals. This research presents a procedure to extract the R-wave locations by forward-backward (FB) algorithm and classify the arrhythmic beat conditions by using RR intervals. The FB algorithm shows forward and backward searching rules from QRS onset and eliminates lower-amplitude signals near the baseline using a statistical process control concept. The proposed algorithm was trained the optimal parameters by using MIT-BIH arrhythmia database (MITDB), and it was verified by actual Holter ECG signals from a local hospital. The signals are classified into normal (N) and three arrhythmia beat types including premature ventricular contraction (PVC), ventricular flutter/fibrillation (VF), and second-degree heart block (BII) beat. This work produces 98.54% accuracy in the detection of R-wave location; 98.68% for N beats; 91.17% for PVC beats; and 87.2% for VF beats in the collected Holter ECG signals, and the results are better than what are reported in literature.

A Study on Reperfusion Arrhythmia II. Relationship between Occlusive Arrhythmia and Reperfusion Arrhythmia (Reperfusion Arrhythmia에 관한 연구 II. 폐색성 부정맥과 Reperfusion Arrhythmia와의 관계)

  • Choi In-Hyuk
    • Journal of Veterinary Clinics
    • /
    • v.6 no.2
    • /
    • pp.281-290
    • /
    • 1989
  • To gain insight into the relationship between the occurrence of occlusive arrhythmia(OA) and the incidence of reperfusion arrhythmia(RA), this study used 25 open-chest dogs anesthetized with halothan, these were ligated between anterior ventricular branch and marginal branch of left circumflex artery for 30 minutes and occlusive arrhythmia were observed during the ligation. After releasing of the ligation, TA were observed during 5 minutes. The results were summerized as follow; 1. Such arrhythmias as ventricular fibrillation(VF), short run type VPC Premature contraction(VPC), Venticular tachycardia(VT), ventricularc and trigeminy VPC(TVPC) were observed during occlusion and reperfusion. 2. The cases occurred VT, SRVPC and TVPC during occlusion necessarily were Incidence of RA. 3. RA never occurred without appearence of occlusive arrhythmias. 4. The occurrence rate of OA showed 55.5% in the incidence group of RA and 24.6% in the non incidence group of RA. 5. The occurrence rate of VPC during occlusion showed 9.9+5.85(episode/min) in the incidence group of RA and 4.46+5.88(episode/min) in the non-incidence group of RA. These results may be estimated that the occurrence of VT, SRVPC and TVPC, and the high occurrence rate of VPC during occlusion can be predicted the incidence.

  • PDF

Optimal R Wave Detection and Advanced PVC Classification Method through Extracting Minimal Feature in IoT Environments (IoT 환경에서 최적 R파 검출 및 최소 특징점 추출을 통한 향상된 PVC 분류방법)

  • Cho, Iksung;Woo, Dongsik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.91-98
    • /
    • 2017
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting minimal feature point based on only R peak through optimal R wave. We propose an optimal R wave detection and PVC classification method through extracting minimal feature point in IoT environment. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 99.758% in R wave detection and the rate of 93.94% in PVC classification.

Effects of Antenatal Depression and Antenatal Characteristics of Pregnant Women on Birth Outcomes: A Prospective Cohort Study (산전우울과 임부의 산전특성이 출산 결과에 미치는 영향: 전향적 코호트 연구)

  • Kim, Hae-Won;Jung, Yeon-Yi
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.4
    • /
    • pp.477-485
    • /
    • 2012
  • Purpose: This study was done to evaluate the effects of antenatal depression on birth outcomes. Methods: The participants were 255 pregnant women who were followed in a prospective study. Of these, 197 cases were examined included birth weight, Apgar scores at 5 minute, premature contraction, complication of labor, delivery types and laboratory data. Descriptive statistics, ANOVA, Chi square test of linear by linear association, Kruskal Wallis test, Relative Risk, univariate and adjusted multiple logistic regression were used for data analysis with SPSS/Win. Results: Level of antenatal depression was associated with low birth weight ($x^2$=7.69, p=.010). High risk pregnancy was a predictor of low birth weight (OR=6.98 [1.21-40.30]) and baby's weight (OR=2.12, [1.05-4.28]). Prepregnancy body mass index (BMI) was a predictor of complications in labor (OR=3.59, [1.03-12.48]). But there were no significant effects of antenatal depression on other birth outcomes. Conclusion: The results of this study indicate that women with antenatal depression, high risk pregnancy, prepregnancy $BMI{\geq}23kg/M^2$ should be monitored and managed to ensure favorable birth outcomes.

Complications amd Mortality After Coronary Artery Bypass Graft Surgery; Collective Review of 61 Cases (관상동맥우회수술후 합병증과 사망율에 대한 임상적 고찰;61례 보고)

  • 조건현
    • Journal of Chest Surgery
    • /
    • v.26 no.7
    • /
    • pp.526-531
    • /
    • 1993
  • Sixty-one consecutive patients with coronary artery bypass graft for myocardial revascularization were retrospectively reviewed to analyze various pattern of postoperative complication and death during hospital stay from Nov. 1988 to Oct. 1992. Fortytwo of the patients were male and nineteen female. The mean age was 56 and 51 years in male and female. Preoperative diagnosises were unstable angina in 14 of patients, stable angina in 28, postmyocardial infarction state in 15, and state of failed percutaneous transluminal coronary angioplasty in 4. 141 stenosed coronary arteries were bypassed with use of 20 pedicled internal mammary artery and 124 reversed saphenous vein grafts. Postoperative complications and perioperative death were as follows: 1. Of 61 patients undergoing operation, peri and postoperative over all complication occured in 15 patients [ 25% ]; newly developed myocardial infarction in 4, intractable cardiac arrhythmia including atrial fibrillation and frequent ventricular premature contraction in 3, bleeding from gastrointestinal tract in 2, persistent vegetative state as a sequele of brain hypoxia in 1, wound necrosis in 1, left hemidiaphragmatic palsy in 3 and poor blood flow through graft in 2. 2. Operative mortality was 8%[5 patients]. 3 out of these died in operating room; 1 patient by bleeding from rupture of calcified aortic wall, 1 by air embolism through left atrial vent catheter, 1 by low cardiac output syndrome. 2 patients died during hospital stay; 1 by acute respiratory distress syndrome with multiuple organ failure, 1 by brain death after delayed diagnosis of pericardial tamponade.

  • PDF

A Improved Case Report of Postmenopausal Syndrome with Palpitation Treated by Korean Medicine Treatment including Jagamcho-tang-gami (자감초탕 가미방을 포함한 한의 복합 치료로 호전된 부정맥을 동반한 폐경기 증후군 1례 : 증례 보고)

  • Hee-Yoon, Lee;Young-Jin, Yoon;Jang-Kyung, Park
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.36 no.1
    • /
    • pp.90-102
    • /
    • 2023
  • Objectives: The purpose of this study is to report the clinical effectiveness of Korean medicine treatment on postmenopausal syndrome. Methods: The patient with postmenopausal syndrome with palpitation was treated with Korean medicine treatment during 14 days of hospitalization. The patient received Korean medicine treatment including herbal medicine, acupuncture and moxibustion. The effect of treatment on postmenopausal syndrome was evaluated through the Numeric Rating Scale (NRS) and questionnaire. Palpitation and arrhythmia was evaluated by Electrocardiogram (ECG) and manual pulse diagnosis three times a day. Result: After the treatment, the clinical postmenopausal symptoms of palpitation and hot flush were improved. Also, ECG's result was improved ventricular premature contraction to normal ECG. Conclusions: This case report proved that the Korean medicine treatment may be effective for improving postmenopausal syndrome with palpitation and hot flush. However, further clinical study is needed in the future to prove the effectiveness of Korean medicine treatment for postmenopausal syndrome with palpitation and hot flush.

The Influence of Gender on Clinical Outcomes in Elderly Patients Underwent Coronary Artery Bypass Grafting Surgery

  • Moon, Seong-Min
    • Biomedical Science Letters
    • /
    • v.17 no.4
    • /
    • pp.329-336
    • /
    • 2011
  • The female has previously been shown to be an independent risk factor for mortality and morbidity after coronary artery bypass grafting surgery (CABG). The aim of this retrospective study is to evaluate gender differences of the perioperative outcomes in elderly patients underwent CABG. Data for seventy elderly patients (>70 years) that underwent CABG (between January 2005 and July 2011) were divided into two groups: male patients (n=33, male group) and female patients group (n=37, female group). Heights, body weights, body surface area and coronary artery obstruction rate (right coronary artery territory) in the female group were lower than those of the male group ($P$ <0.05). History of hypertension, hyperlipidemia, congestive heart failure and percutaneous coronary artery intervention in the female group was higher than that of the male group ($P$ <0.05). Total cholesterol and brain natriuretic peptide levels in the female group were higher than those of the male group ($P$ <0.05). Platelet count in the female group was higher than the male group at preoperative (Pre-OP) period ($P$ <0.05). Erythrocyte count, hematocrit and hemoglobin levels in the female group were lower than those of the male group at Pre-OP period ($P$ <0.05). But, erythrocyte count, hematocrit and hemoglobin levels in the female group were higher than those of the Male group at postoperative (Post-OP) period ($P$ <0.05). Left ventricular ejection fraction in the female group was higher than the male group at Post-OP period ($P$ <0.05). Hospital stay length in the female group was higher than the male group ($P$ <0.05). Post-OP bleeding volume and incidence of ventricular premature contraction in the female group were lower than those of the male group ($P$ <0.05). These results suggest that despite female gender have a greater risk factors and require a longer hospitalization than male, there was no significant difference incidence of mortality and complication.

Antiarrhythmic Effects of KR-32570, a Novel Na+-H+ Exchanger Inhibitor, on Ischemia/Reperfusion-Induced Arrhythmias

  • Hwang, Geum-Shil;Seo, Ho-Won;Lee, Kyu-Yang;Lee, Sun-Kyung;Yoo, Sung-Eun;Lee, Byung-Ho
    • Biomolecules & Therapeutics
    • /
    • v.13 no.1
    • /
    • pp.20-25
    • /
    • 2005
  • The present study was performed to evaluate antiarrhythmic effects of KR-32570, a novel inhibitor of sodium hydrogen exchanger subtype-1 (NHE-1), in rat arrhythmia induced by focal ischemia and reperfusion. During ischemia, KR-32570 significantly decreased the number of premature ventricular contraction (PVC) from 152.0 times to 75.5, 52.4 and 20.0 times for 0.1, 0.3 and 1.0 mg/kg, respectively (p<0.05) and the duration of ventricular tachycardia (VT) from 88.1 s to 35.8, 7.7 and 1.3 s, respectively(p<0.05) in anesthetized rats subjected to 10-min coronary occlusion of coronary artery. Similarlt to ischemia-induced arrhythmia, KR-32570 significantly decreased reperfusion-induced arrhythmia including PVC (41.3, 21.5, 11.3 and 6.6 times at vehicle, 0.1, 0.3 and 1.0 mg/kg, respectively, p<0.05) and VT (100.5, 64.2, 25.8 and 25.2 s, respectively, p<0.05), and VF (86.9, 27.5, 6.9 and 0 s, respectively, p<0.05). Moreover, KR-32570 dose-dependently decreased the incidence of mortality occurring after reperfusion (41, 27, 18 and 0% at vehicle, 0.1, 0.3, 1.0 mg/kg, respectively). These results suggest that KR-32570 has a potent antiarrhythmic effect in rat arrhythmia induced by ischemia and reperfusion.

Classification of the PVC Using The Fuzzy-ART Network Based on Wavelet Coefficient (웨이브렛 계수에 근거한 Fuzzy-ART 네트워크를 이용한 PVC 분류)

  • Park, K. L;Lee, K. J.;lee, Y. S.;Yoon, H. R.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.435-442
    • /
    • 1999
  • A fuzzy-ART(adaptive resonance theory) network for the PVC(premature ventricular contraction) classification using wavelet coefficient is designed. This network consists of the feature extraction and learning of the fuzzy-ART network. In the first step, we have detected the QRS from the ECG signal in order to set the threshold range for feature extraction and the detected QRS was divided into several frequency bands by wavelet transformation using Haar wavelet. Among the low-frequency bands, only the 6th coefficient(D6) are selected as the input feature. After that, the fuzzy-ART network for classification of the PVC is learned by using input feature which comprises of binary data converted by applying threshold to D6. The MIT/BIH database including the PVC is used for the evaluation. The designed fuzzy-ART network showed the PVC classification ratio of 96.52%.

  • PDF