• Title/Summary/Keyword: Predictive Control

Search Result 1,074, Processing Time 0.025 seconds

Refractive Error Induced by Combined Phacotrabeculectomy (섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Park, Ji Hae;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1173-1180
    • /
    • 2018
  • Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. -0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (-1.07 vs. -0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy.

Comparison of the National Early Warning Score+Lactate score with the pre-endoscopic Rockall, Glasgow-Blatchford, and AIMS65 scores in patients with upper gastrointestinal bleeding

  • Kim, Daejin;Jo, Sion;Lee, Jae Baek;Jin, Youngho;Jeong, Taeoh;Yoon, Jaechol;Park, Boyoung
    • Clinical and Experimental Emergency Medicine
    • /
    • v.5 no.4
    • /
    • pp.219-229
    • /
    • 2018
  • Objective We compared the predictive value of the National Early Warning Score+Lactate (NEWS+L) score with those of other parameters such as the pre-endoscopic Rockall score (PERS), Glasgow-Blatchford score (GBS), and albumin, international normalized ratio, altered mental status, systolic blood pressure, age older than 65 years score (AIMS65) among patients with upper gastrointestinal bleeding (UGIB). Methods We conducted a retrospective study of patients with UGIB during 2 consecutive years. The primary outcome was the composite of in-hospital death, intensive care unit admission, and the need for ${\geq}5$ packs of red blood cell transfusion within 24 hours. Results Among 530 included patients, the composite outcome occurred in 59 patients (19 inhospital deaths, 13 intensive care unit admissions, and 40 transfusions of ${\geq}5$ packs of red blood cells within 24 hours). The area under the receiver operating characteristic curve of the NEWS+L score for the composite outcome was 0.76 (95% confidence interval, 0.70 to 0.82), which demonstrated a significant difference compared to PERS (0.66, 0.59-0.73, P=0.004), but not to GBS (0.70, 0.64-0.77, P=0.141) and AIMS65 (0.76, 0.70-0.83, P=0.999). The sensitivities of NEWS+L scores of 3 (n=34, 6.4%), 4 (n=92, 17.4%), and 5 (n=171, 32.3%) were 100%, 98.3%, and 96.6%, respectively, while the sensitivity of an AIMS65 score of 0 (n=159, 30.0%) was 91.5%. Conclusion The NEWS+L score showed better discriminative performance than the PERS and comparable discriminative performance to the GBS and AIMS65. The NEWS+L score may be used to identify low-risk patients among patients with UGIB.

Validity of Self-reported Hypertension and Factors Related to Discordance Between Self-reported and Objectively Measured Hypertension: Evidence From a Cohort Study in Iran

  • Najafi, Farid;Pasdar, Yahya;Shakiba, Ebrahim;Hamzeh, Behrooz;Darbandi, Mitra;Moradinazar, Mehdi;Navabi, Jafar;Anvari, Bita;Saidi, Mohammad Reza;Bazargan-Hejazi, Shahrzad
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.2
    • /
    • pp.131-139
    • /
    • 2019
  • Objectives: Self-reporting can be used to determine the incidence and prevalence of hypertension (HTN). The present study was conducted to determine the validity of self-reported HTN and to identify factors affecting discordance between self-reported and objectively measured HTN in participants in the Ravansar Non-Communicable Diseases (RaNCD) cohort. Methods: The RaNCD cohort included permanent residents of Ravansar, Iran aged 35-65 years. Self-reported data were collected before clinical examinations were conducted by well-trained staff members. The gold standard for HTN was anti-hypertensive medication use and blood pressure measurements. The sensitivity, specificity, positive and negative predictive values, and overall accuracy of self-reporting were calculated. Univariate and multivariate logistic regression were used to examine the discordance between self-reported HTN and the gold standard. Results: Of the 10 065 participants in the RaNCD, 4755 (47.4%) were male. The prevalence of HTN was 16.8% based on self-reporting and 15.7% based on medical history and HTN measurements. Of the participants with HTN, 297 (18.8%) had no knowledge of their disease, and 313 (19.9%) had not properly controlled their HTN despite receiving treatment. The sensitivity, specificity, and kappa for self-reported HTN were 75.5%, 96.4%, and 73.4%, respectively. False positives became more likely with age, body mass index (BMI), low socioeconomic status, and female sex, whereas false negatives became more likely with age, BMI, high socioeconomic status, smoking, and urban residency. Conclusions: The sensitivity and specificity of self-reported HTN were acceptable, suggesting that this method can be used for public health initiatives in the absence of countrywide HTN control and detection programs.

The Effects of Metacognitive Training in Math Problem Solving Using Smart Learning System (스마트 러닝 시스템을 활용한 수학 문제 풀이 맥락에서 메타인지 훈련의 효과)

  • Kim, Sungtae;Kang, Hyunmin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.441-452
    • /
    • 2022
  • Training using metacognition in a learning environment is one of the topics that have been continuously studied since the 1990s. Metacognition can be broadly divided into declarative metacognitive knowledge and procedural metacognitive knowledge (metacognitive skills). Accordingly, metacognitive training has also been studied focusing on one of the two metacognitive knowledge. The purpose of this study was to examine the role of metacognitive skills training in the context of mathematical problem solving. Specifically, the learner performed the prediction of problem difficulty, estimation of problem solving time, and prediction of accuracy in the context of a test in which problems of various difficulty levels were mixed within a set, and this was repeated 5 times over a total of 5 weeks. As a result of the analysis, we found that there was a significant difference in all three predictive indicators after training than before training, and we revealed that training can help learners in problem-solving strategies. In addition, we analyzed whether there was a difference between the experiment group and control group in the degree of test anxiety and math achievement. As a result, we found that learners in the experiment group showed less emotional and relationship anxiety at 5 weeks. This effect through metacognitive skill training is expected to help learners improve learning strategies needed for test situations.

Effect of Loess Bedding with Loess Nanoparticles on Sleep Disorder (황토나노입자를 부착한 황토이불 사용이 수면장애에 미치는 효과)

  • Lee, Ku Yeon;Hahm, Suk Chan
    • Journal of Naturopathy
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Background: No studies have reported on the effects of loess beddings on insomnia patients. Purpose: It studied the change in quality of life and quality of sleep after having 15 insomnia subjects use the bedding that emits far-infrared rays. Methods: After using loess bedding for the test group and general yellow bedding for the control group, the study was conducted in the form of a questionnaire on the WHO quality of life of the subjects. Results: In the overall quality of life evaluation, the pre-and post-changes significantly improved in the test group. Using loess bedding was greatly enhanced the physical change, the actual sleep time, and the quality of sleep of the test group. The period of sleep was significantly longer post-treating, and the habitual sleep efficiency was considerably higher, and sleep disturbance was significantly lower than before in the test group. Sleep drug use and daytime dysfunction after treating in the test group significantly improved the sleep effect. Changes in the Sociality Scale, Environmental Change Scale, and Quality of Life Scale significantly improved in the test group. The quality of life for 14 items in the test group was significantly correlated. Daytime drowsiness, depression, and anxiety scale changes were significantly improved in the test group. According to the predictive survey, the subjects felt warmth in their body and comfort in mind during and after using loess bedding and evaluated that sleep quality was good. Conclusions: The overall quality of life in the test group increased using loess bedding.

The Role of Tolerance to Promote the Improving the Quality of Training the Specialists in the Information Society

  • Oleksandr, Makarenko;Inna, Levenok;Valentyna, Shakhrai;Liudmyla, Koval;Tetiana, Tyulpa;Andrii, Shevchuk;Olena, Bida
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.12
    • /
    • pp.63-70
    • /
    • 2022
  • The essence of the definition of "tolerance" is analyzed. Motivational, knowledge and behavioral criteria for tolerance of future teachers are highlighted. Indicators of the motivational criterion are the formation of value orientations, motivational orientation, and the development of empathy. Originality and productivity of thoughts and judgments, tact of dialogue, pedagogical ethics and tact are confirmed as indicators of the knowledge criterion. The behavioral criterion includes social activity as a life position, emotional and volitional endurance, and self-control of one's own position. The formation of tolerance is influenced by a number of factors: the social environment, the information society, existing stereotypes and ideas in society, the system of education and relationships between people, and the system of values. The main factors that contribute to the education of tolerance in future teachers are highlighted. Analyzing the structure of tolerance, it is necessary to distinguish the following functions of tolerance: - motivational (determines the composition and strength of motivation for social activity and behavior, promotes the development of life experience, because it allows the individual to accept other points of view and vision of the solution; - informational (understanding the situation, the personality of another person); - regulatory (tolerance has a close connection with the strong - willed qualities of a person: endurance, selfcontrol, self-regulation, which were formed in the process of Education); - adaptive (allows the individual to develop in the process of joint activity a positive, emotional, stable attitude to the activity itself, which the individual carries out, to the object and subject of joint relations). The implementation of pedagogical functions in the information society: educational, organizational, predictive, informational, communicative, controlling, etc. provides grounds to consider pedagogical tolerance as an integrative personal quality of a representative of any profession in the field of "person-person". The positions that should become conditions for the formation of tolerance of the future teacher in the information society are listed.

Structural Performance Evaluation of Anchors for Power Equipment Electrical Cabinets Considering On-Site Installation Conditions (현장 설치 조건을 고려한 발전설비 전기 캐비닛 정착부 앵커의 구조성능 평가)

  • Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.709-719
    • /
    • 2023
  • In general, most of the electrical equipment responsible for control within power plants is housed in self-standing cabinets. These cabinets are typically fixed to a slab using post-installed anchors. Although the fixation method of using post-installed anchors provides stability, there is a risk of conductor failure due to external forces, including moments. However, the performance assessment of current anchors is only evaluated through uniaxial material tests. Therefore, the primary purpose of this study is to compare the static performance of post-installed anchors, considering on-site installation conditions, with their performance in material tests and to analyze the behavioral characteristics of the anchors. While conducting experiments using actual cabinets would be ideal, practical and spatial constraints make this approach difficult. As an alternative, experiments were conducted using a test specimen consisting of a steel column and a support. As a result, the pull-out performance of anchors reflecting on-site installation conditions was measured to be about 10% higher than that observed in material tests. The trends in load reduction and the point of maximum performance for the anchors also differed. To verify the reliability of the experimental study, a 3D FEM analysis was performed, which will provide predictive information on the loads transferred to the post-installed anchors for structural performance evaluations of electrical cabinets using shaking table test in the future.

Optimum Radiotherapy Schedule for Uterine Cervical Cancer based-on the Detailed Information of Dose Fractionation and Radiotherapy Technique (처방선량 및 치료기법별 치료성적 분석 결과에 기반한 자궁경부암 환자의 최적 방사선치료 스케줄)

  • Cho, Jae-Ho;Kim, Hyun-Chang;Suh, Chang-Ok;Lee, Chang-Geol;Keum, Ki-Chang;Cho, Nam-Hoon;Lee, Ik-Jae;Shim, Su-Jung;Suh, Yang-Kwon;Seong, Jinsil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.143-156
    • /
    • 2005
  • Background: The best dose-fractionation regimen of the definitive radiotherapy for cervix cancer remains to be clearly determined. It seems to be partially attributed to the complexity of the affecting factors and the lack of detailed information on external and intra-cavitary fractionation. To find optimal practice guidelines, our experiences of the combination of external beam radiotherapy (EBRT) and high-dose-rate intracavitary brachytherapy (HDR-ICBT) were reviewed with detailed information of the various treatment parameters obtained from a large cohort of women treated homogeneously at a single institute. Materials and Methods: The subjects were 743 cervical cancer patients (Stage IB 198, IIA 77, IIB 364, IIIA 7, IIIB 89 and IVA 8) treated by radiotherapy alone, between 1990 and 1996. A total external beam radiotherapy (EBRT) dose of $23.4\~59.4$ Gy (Median 45.0) was delivered to the whole pelvis. High-dose-rate intracavitary brachytherapy (HDR-IBT) was also peformed using various fractionation schemes. A Midline block (MLB) was initiated after the delivery of $14.4\~43.2$ Gy (Median 36.0) of EBRT in 495 patients, while In the other 248 patients EBRT could not be used due to slow tumor regression or the huge initial bulk of tumor. The point A, actual bladder & rectal doses were individually assessed in all patients. The biologically effective dose (BED) to the tumor ($\alpha/\beta$=10) and late-responding tissues ($\alpha/\beta$=3) for both EBRT and HDR-ICBT were calculated. The total BED values to point A, the actual bladder and rectal reference points were the summation of the EBRT and HDR-ICBT. In addition to all the details on dose-fractionation, the other factors (i.e. the overall treatment time, physicians preference) that can affect the schedule of the definitive radiotherapy were also thoroughly analyzed. The association between MD-BED $Gy_3$ and the risk of complication was assessed using serial multiple logistic regression models. The associations between R-BED $Gy_3$ and rectal complications and between V-BED $Gy_3$ and bladder complications were assessed using multiple logistic regression models after adjustment for age, stage, tumor size and treatment duration. Serial Coxs proportional hazard regression models were used to estimate the relative risks of recurrence due to MD-BED $Gy_{10}$, and the treatment duration. Results: The overall complication rate for RTOG Grades $1\~4$ toxicities was $33.1\%$. The 5-year actuarial pelvic control rate for ail 743 patients was $83\%$. The midline cumulative BED dose, which is the sum of external midline BED and HDR-ICBT point A BED, ranged from 62.0 to 121.9 $Gy_{10}$ (median 93.0) for tumors and from 93.6 to 187.3 $Gy_3$ (median 137.6) for late responding tissues. The median cumulative values of actual rectal (R-BED $Gy_3$) and bladder Point BED (V-BED $Gy_3$) were 118.7 $Gy_3$ (range $48.8\~265.2$) and 126.1 $Gy_3$ (range: $54.9\~267.5$), respectively. MD-BED $Gy_3$ showed a good correlation with rectal (p=0.003), but not with bladder complications (p=0.095). R-BED $Gy_3$ had a very strong association (p=<0.0001), and was more predictive of rectal complications than A-BED $Gy_3$. B-BED $Gy_3$ also showed significance in the prediction of bladder complications in a trend test (p=0.0298). No statistically significant dose-response relationship for pelvic control was observed. The Sandwich and Continuous techniques, which differ according to when the ICR was inserted during the EBRT and due to the physicians preference, showed no differences in the local control and complication rates; there were also no differences in the 3 vs. 5 Gy fraction size of HDR-ICBT. Conclusion: The main reasons optimal dose-fractionation guidelines are not easily established is due to the absence of a dose-response relationship for tumor control as a result of the high-dose gradient of HDR-ICBT, individual differences In tumor responses to radiation therapy and the complexity of affecting factors. Therefore, in our opinion, there is a necessity for individualized tailored therapy, along with general guidelines, in the definitive radiation treatment for cervix cancer. This study also demonstrated the strong predictive value of actual rectal and bladder reference dosing therefore, vaginal gauze packing might be very Important. To maintain the BED dose to less than the threshold resulting in complication, early midline shielding, the HDR-ICBT total dose and fractional dose reduction should be considered.

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Quantitative Microbial Risk Assessment Model for Staphylococcus aureus in Kimbab (김밥에서의 Staphylococcus aureus에 대한 정량적 미생물위해평가 모델 개발)

  • Bahk, Gyung-Jin;Oh, Deog-Hwan;Ha, Sang-Do;Park, Ki-Hwan;Joung, Myung-Sub;Chun, Suk-Jo;Park, Jong-Seok;Woo, Gun-Jo;Hong, Chong-Hae
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.484-491
    • /
    • 2005
  • Quantitative microbial risk assessment (QMRA) analyzes potential hazard of microorganisms on public health and offers structured approach to assess risks associated with microorganisms in foods. This paper addresses specific risk management questions associated with Staphylococcus aureus in kimbab and improvement and dissemination of QMRA methodology, QMRA model was developed by constructing four nodes from retail to table pathway. Predictive microbial growth model and survey data were combined with probabilistic modeling to simulate levels of S. aureus in kimbab at time of consumption, Due to lack of dose-response models, final level of S. aureus in kimbeb was used as proxy for potential hazard level, based on which possibility of contamination over this level and consumption level of S. aureus through kimbab were estimated as 30.7% and 3.67 log cfu/g, respectively. Regression sensitivity results showed time-temperature during storage at selling was the most significant factor. These results suggested temperature control under $10^{\circ}C$ was critical control point for kimbab production to prevent growth of S. aureus and showed QMRA was useful for evaluation of factors influencing potential risk and could be applied directly to risk management.