• Title/Summary/Keyword: Precooler

Search Result 15, Processing Time 0.024 seconds

A study on energy efficiency improvement of waste-water treatment system by freeze concentration method (동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.467-476
    • /
    • 2013
  • Freeze concentration method has advantages of high thermodynamic efficiency, low energy consumption and purified water re-use. In this study, freeze concentration waste-water system which was designed as the small and medium sized capacity was analyzed about the rate of electric power consumption and the daily treatment capacity to suggest the direction of system development. At first, power consumption and operation time of the system with fresh water precooler or without it was calculated by computer modeling and analysis. Subsequently, the change of design treatment capacity was applied to the system with fresh water cooler. As a result, the rate of electric power consumption was higher as 0.6 Wh/kg but daily treatment capacity increased in quantity as 19 % in the system with fresh water precooler. As design treatment capacity increased, the rate of electric power consumption was lower and daily treatment capacity was larger in quantity.

Cycle Simulations for Power Saving BIP(block ice plant) design (절전형 제빙시설 설계를 위한 사이클 모사)

  • Kang, Jong-Ho;Kim, Nam-Jin;Lee, Jae-Yong;Kim, Chong-Bo
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.216-221
    • /
    • 2000
  • Most Ice making companies make simple efforts to make products and fail to introduce improvements into the system against huh cost of products. The work presented here is an implementation of ice making method to improve both energy efficiency and productivity. In this present investigation, several ice making cycles are designed and calculated to evaluate COP, ice making time and electric energy consumption. Results obtained shows that COP is improved with more efficient use of time for ice making and electric consumption. Therefore this can offer the opportunity for more efficient energy consumption and productivity in ice making.

  • PDF

Effect of Precooling on Removal of Field Heat and Respiration Rate of Vegetable Corn(Zes Mays L.) (예냉처리가 풋옥수수의 냉각속도 및 호흡량 변화에 미치는 영향)

  • 손영구;김성열
    • Food Science and Preservation
    • /
    • v.3 no.1
    • /
    • pp.55-60
    • /
    • 1996
  • To obtain the basic data on precooling effects for establishment the suitable postharvest handling technique or method of keeping high quality of vegetalble corn, the sweet, supersweet and waxy corn, (Danok #2, Cocktail #86 and Chalok #1), being mainly consumed as vegetables in Korea, were precooled with ice or vacuum cooling method immediately after harvest. The vacuum cooling was the most effective for the field heat removal of vegetable corn. It took only 30 min. at 4 to 5 torr of cold chamber pressure of vacuum precooler to lower the corn temperature from 30 to 2$^{\circ}C$. The ice cooling was also thought to be a useful precooling method with relatively short cooling time of 6 hrs. The vegetable corn treated with vacuum or ice cooling showed low and stable respiration rates of 25.5 to 43.5 CO2 mg/kg/hr. when stored at 0∼2$^{\circ}C$ while the samples stored at room temperature (20∼25$^{\circ}C$) without precooling were as high as 64.1 to 245 CO, mg/kg/hr.

  • PDF

Analysis of Performance and Economical Efficiency through Cycle Simulation for Power Saving BIP(Block Ice Plant) (절전형 제빙시설 사이클 모사를 통한 성능 및 경제성 해석)

  • 강종호;김남진;이재용;김종보
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.455-461
    • /
    • 2001
  • Domestic ice making companies make effort to obtain products and neglect to introduce low cost product improvements with energy savings. The work presented here is an implementation of ice making method to improve both energy efficiency and productivity. In this present investigation, several ice making cycles are proposed for higher efficiency in the system. COP(Coefficient of Performance), ice making time and electric energy consumption are evaluated and compared with the conventional system. Results shows that COP is improved with more efficient use of time for ice making and electric consumption. Therefore, this can offer an opportunity for more efficient use of energy and higher productivity in ice making.

  • PDF

Performance Analysis of Air Turbo Ramjet using $H_2$ and $CH_4$ (수소와 메탄 연료를 사용한 에어 터보 램제트 엔진의 성능해석)

  • 이양지;차봉준;양수석;이대성;김형진
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 2003
  • The present work was conducted to achieve the better understanding of the performance analysis technique for the expander type air turbo ramjet engine. For this purpose, the performance analysis was carried out using a small engine(8.0kN thrust) with two types of fuels. From this analysis, at the same input condition, the thrust of methane-fueled engine was 25% lower than that of hydrogen. In addition, the case of methane shows the inapplicable engine performance cycle.(i.e., The compressor work exceeds the turbine output power) These results come mainly from the different heating value of each fuel and specific heat. This analysis also shows that, to build a same performance cycle as the hydrogen case, the methane-fueled engine requires increased air and fuel flow rates, increased turbine expansion ratio, and decreased compressor pressure ratio.

Study on the Fundamental Technologies of ATREX Engine

  • Sato, Tetsuya;Kobayashi, Hiroaki;Tanatsugu, Nobuhiro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.665-670
    • /
    • 2004
  • This paper reviews the latest studies of the expander cycle Air Turbo Ramjet engine (ATREX) conducted in JAXA. First, a system analysis including the vehicle and trajectory was conducted to optimize the engine cycle and turbo-machine configuration. We selected the precooled turbo-jet cycle for a prototype engine using the near term technologies. Second, a system ground-firing test was conducted to verify a defrosting system for the precooler. Methanol injection with its particles atomization could compensate 80 % of pressure loss caused by the frost. Thirdly, a feasibility of carbon/carbon composites for the engine components was investigated by making complex shapes such as a heat exchanger and a plug nozzle. Basic technologies on the gas leakage, the junction and bonding were also studied. The end of the paper, some basic studies such as wind tunnel tests of a new type air inlet and a plug nozzle are described.

  • PDF

A Study on the Characteristics of Refrigeration System Installed with Precooler, and Liquid-Vapor Separator after Expansion Device (과냉각기와 팽창장치 후 액기분리기를 적용한 냉동시스템 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • The purpose of research is to understand the characteristics of refrigeration system having a liquid-vapor phase separator after expansion device and precooling heat exchanger. After expansion process of typical refrigerant of freezer, R134a, the cold vapor of the expanded refrigerant mixture is separated in the liquid-vapor separator and introduced in the precooling heat exchanger to enable the liquid refrigerant to be subcooled. The analysis results showed that the increasing rate of refrigeration capacity and COP can be 8.6% and 1.4%, each. The cause of these performance improvements is due to the difference of the slope of saturated vapor and saturated liquid lines in Mollier diagram of refrigerant.

Performance test of Joule-Thomson cryocooler with $H_2$gas (수소 Joule-Thomson냉동기의 성능실험)

  • 백종훈;강병하;홍성제;장호명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.457-463
    • /
    • 1999
  • The Joule-Thomson cryocooler with $H_2$gas has been developed. Cool-down characteristics and the cooling performance of a JT cryocooler have been investigated in detail. The JT cryocooler consists of JT expansion valve, heat exchanger, expansion chamber, compressed $H_2$gas storage tank, $LN_2$precooler, heater and a cryostat. The precooling process using both $GN_2$and $LN_2$was peformed to cool down the inside components of cryocooler under the maximum inversion temperature of $H_2$. The $H_2$expansion experiments have been peformed for 2-5MPa of H$_2$pressure to evaluate steady state temperatures of the cryocooler. It is found that the steady state temperatures are decreased as the H$_2$pressures are increased. The effects of cooling temperatures on the performance have been evaluated for various $H_2$and $N_2$pressures. It is seen that the cooling loads are increased, as the cooling temperature and operating pressure are increased.

  • PDF

New reliquefaction system of Boil-Off-Gas by LNG cold energy (LNG냉열이용 BOG 재액화긍정 해석연구)

  • 윤상국;최형식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.256-263
    • /
    • 2002
  • The Boil-Off-Gases(BOG) in the LNG production terminal are continuously generated during the unloading, storage and supply processes by the heat penetration. In order to use these gases as useful fuel, the reliquefaction process should be installed to put the reliquefied BOG in the main LNG supply line before the secondary pump in terminal. The current reliquefaction method of BOG in LNG terminal is the direct contact one between LNG and BOG in the absorption column. But the system has severe disadvantage, which is the 10 times of LNG circulation needed for unit mass of BOG reliquefaction. It causes, therefore, high power consumption of LNG circulation pump and excessive city-gas supply, even if short demand of NG is needed in the summer time. In this paper, the new reliquefaction system of BOG by using LNG cold energy with indirect contact in precooler was suggested and analysed. The result showed new indirect contact method of BOG reliquefaction system between LNG cold energy and BOG is much more effective than the current direct contact one because of only about 1.3 times of LNG circulation needed and higher energy saving by pump power reduction.