• 제목/요약/키워드: Precision medicine (PM)

검색결과 46건 처리시간 0.026초

새로운 맞춤형 정밀의학과 보건의료 연구에 대한 조망 (Perspective of a New Precision Medicine and Health Care Research)

  • 박윤형
    • 보건행정학회지
    • /
    • 제25권4호
    • /
    • pp.253-255
    • /
    • 2015
  • The concept of precision medicine-prevention and treatment strategies that take individual variability into account-is hot issue of US in the year 2015. Precision medicine is a new concept that approach patients individually by there characteristics, such as genome, life style, environmental exposure, etc. For developing the precision medicine, National Institute of Health of US has been prepared the Precision Medicine Initiative Cohort Program, at least 1 million people cohort. The US President Obama announced the Precision Medicine Initiative on 30th January 2015. He announced that he will pioneer a new model of patient-powered research that promises to accelerate biomedical discoveries and provide clinicians with new tools, knowledge, and therapies to select which treatments will work best for which patients. Most medical treatments have been designed for the 'average patient.' As a result of this 'one-size-fits-all-approach,' treatments can be very successful for some patients but not for others. This is changing with the emergence of precision medicine, an innovative approach to disease prevention and treatment that takes into account individual differences in people's genes, environments, and lifestyles. Precision medicine gives clinicians tools to better understand the complex mechanisms underlying a patient's health, disease, or condition, and to better predict which treatments will be most effective. The healthcare researcher should prepare the new medicine era such as bio-information technology convergence, big data study.

방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가 (The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay)

  • 노경운;김태훈;김지영;김현주;이호영;최준영;이병일;최재걸;이동수
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.116-124
    • /
    • 2011
  • 핵의학 검체검사 외부정도관리 숙련도시험을 평가 지표인 정밀도 및 회수율 측정을 학회에서 시행하고 있는 외부정도 관리혈청과 정확도 기반 WHO 인증표준물질을 사용하여 핵의학검사실에서 널리 사용하고 있는 방사면역측정법과 진단검사의학과에서 자동화장비를 이용하는 주된 방법인 화학발광면역측정법을 2009년, 2010년 각각 2회씩 총 4회를 시행하였다. 2009년도 종양 표지자 5종에서 측정 간 정밀도는 RIA는 평균 $14.8{\pm}4.2%$, EIA(CLIA)는 평균 $19.2{\pm}6.9%$ 이며, 두 방법 간 유의한 차이는 없었다(p>0.05). 2010년도 종양 표지자와 갑상선 기능검사 9종에서 RIA는 평균 $13.8{\pm}6.1%$, EIA(CLIA)는 평균 $15.5{\pm}7.7%$로 RIA 검사는 AFP, CEA, PSA, CA 125, $T_3$, $T_4$, TSH 종목에서 측정 간 정밀도 허용범위인 20% 이내로 양호한 결과를 보였고, 허용범위를 벗어난 CA 19-9는 p value 0.345로 유의한 차이는 없었다. 2010년도 WHO 인증표준물질을 사용한 RIA 검사 회수율 측정에서 AFP, PSA, $T_4$, TSH는 92~103%로 양호한 회수율을 보였다. CEA, CA 125, CA 19-9는 WHO 인증표준물질이 아닌 상품화된 정도관리물질을 사용하여 낮은 회수율을 보였으나, 유의한 차이는 없었다(p>0.05). $T_3$ 종목에서 RIA는 $118{\pm}21.1%$를 보였으나, EIA(CLIA)에서는 $145{\pm}22.9%$로 과대평가된 높은 회수율을 보였고, TSH 종목에서 RIA는 $103{\pm}9.6%$로 좋은 회수율을 보였지만, EIA(CLIA)는 $67{\pm}15.3%$로 낮은 회수율을 보였다. 방사면역측정법은 자동화장비를 이용한 화학발광면역측정법과의 숙련도 비교평가에서 측정 간 정밀도는 허용범위인 20% 이내 또는 두 방법 간 유의한 차이는 없었다(p>0.05). 회수율은 WHO 인증표준물질을 이용한 종목에서 90~110%로 양호한 결과를 보였고, 이외 종목에서도 두 방법 간 유의한 차이는 없었다(p>0.05). 따라서 방사면역측정법은 임상의에게 저렴한 비용으로 정확한 결과를 신속하게 보고할 수 있으며, 지속적으로 핵의학 체외진단키트에 대한 성능평가를 WHO 인증표준물질과 외부정도관리 숙련도 시험과 병행하여 수행함으로서 KOLAS 국제공인메디칼시험기관으로 인정받고 국제화와 검사실 표준화를 통하여 질 향상을 이루어야 한다.

  • PDF

혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교 (Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol)

  • 최성희;노경운;김진의;송요성;팽진철;강건욱;이동수
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.72-80
    • /
    • 2015
  • Estradiol($E_2$)은 월경 주기와 배란유도 및 불임 및 폐경을 진단하는데 유용한 지표이다. 따라서 정도인증 평가 지표인 정밀도(precision), 회수율(accuracy), 예민도(sensitivity) 및 타 키트와의 상관성(comparison) 비교를 통하여 우수한 키트를 선정하여 사용함으로서 핵의학검사실 표준화와 질 향상을 도모하고자 본 연구를 시행하였다. 핵의학검사실에서 사용하고 있는 방사면역측정법(Radioimmunoassay; RIA)으로 SIEMENS (Coat-A-Count Estradiol, USA), DIAsource (Immunoassays S.A.. Belgium), AMP (As bach Medical Products GMBH, Germany), BECKMAN COULTER (IMMUNOTECH s.r.o. Czech Republic), Beckman Coulter Ultra Sensitive Estradiol (IMMUNOTECH s.r.o. Czech Republic), CIS Bio (France), MP (ICN Biomedicals, Germany) 7개 키트와 화학발광면역측정법으로 검사하는 E170 (Roche Diagnostics, Germany), Architect (ABBOTT, USA) 2종류의 자동화장비로 측정하였다. 측정 내 정밀도는 키트별로 농도에 따라 다르게 측정 되었으며, 측정값이 낮은 저농도에서는 10.9~13.6% 변이계수를 보였으며, 중, 고농도에서는 모든 키트가 10% 이내의 결과를 보였다. 키트간 상관성 평가를 위한 ANOVA 분석에서 저농도, 중농도, 고농도 검체 각각에 대하여 대부분 키트 간에 유의한 상관관계를 보였으나 일부 키트에서는 유의하지 않은 결과를 보이기도 하였다. 측정 간 정밀도는 측정값이 낮은 저(Low) 농도에서는 10.8~12.3% 변이계수를 보였으며, 중(Medium), 고(High)농도에서는 모든 키트가 10% 이내의 결과를 보였다. 회수율은 IEMENS $92.7{\pm}12.4%$, DIAsou rce $101.4{\pm}18.4%$, AMP $95.1{\pm}11.5%$, BECKMAN COULTER $108.4{\pm}18.5%$, BECKMAN COULTER Ultra Sensitive $104.2.{\pm}13.5%$, CIS Bio $101.3{\pm}11.6%$, MP $93.1{\pm}13.2%$ 이다. 예민도(pg/mL)는 SIEMENS 7.5, DIAsource 6.2, AMP 5.7, BECKMAN COULTER 6.2, BECKMAN COULTER Ultra Sensitive 5.3, CIS Bio 4.5, MP 5.5 이다. 상관성에서는 저농도에서는 MP 키트가 타 키트에 비해 다소 높게 측정되었으며, 중, 고농도에서는 E170 장비가 다소 높게 측정되었다. 외부정도관리 숙련도 시료를 이용한 측정값에서는 타 키트에 비하여 SIEMENS 키트는 낮은 경향을 보였으며, E170, Architect, MP 키트들은 다소 높은 경향을 보였다. $E_2$ 검사 측정 키트 및 방법들은 전체적으로 정밀도, 회수율, 민감도 등의 지표에서 검사에 이용하는 데 무리가 없으나, 키트 변경 시에는 검사의 일관성 유지를 위하여 상호 상관성을 고려하여야 할 것이다.

  • PDF

Monitoring Ovarian Function by Solid- Phase Chemiluminescence Immunoassay

  • 김종배;구병삼
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제9권1_2호
    • /
    • pp.43-53
    • /
    • 1982
  • 여성의 난소기능은 뇨중 Oestrone-3-glucuronide를 간편한 solid-phase 의 화학발광성 면역학적 측정법 (Chemiluminescence Imrnunoassay(CIA) 에 의하여 그 기능이 탐지될 수 있다. Oestrone-3-g1ucuronyl-6-bovine serum albumine에 대한 antiserum의 IgG fraction은 polystyrene 실험관벽에 흡착시켰으며, 항원으로서는 est r one-3- gl ucuronyI-6-aminoethyl-ethyl-isoluminol 을 항원 (antigen) 에 labeI 시킨 것이다. 시험 대상물인 뇨는 매일아침뇨(early morning urine) 을 희석 (1:1000 V/V)한 후 100mcl 를 취하여 이를 각기 이중분석액으로 택하였다. 시험관 내에서 결합반응 (1 hour at $4^{\circ}C)이 일어난 후에는 시험관내의 액체를 전부 흡입 폐기시켰으며, 항체반응이 일어난 후 ( antibody-bound fraction )에는 완충액 (400mcl)으로 한번 세척시켰다. 그후 염화수산화물(2N , 200mcl)을 가지고 $22^{\circ}C$에 60 분간 방치 혼합케 한 후 효소(microperoxidase) 와 과산화수소를 가하면서 산화작용에서 발생되는 발광양을 10초동안 측정하여 그 결과를 분석하였다. 위에 기술한 분석방법을 평가하면 다음과 같은 결론을 얻었다. Calibration curve sensitivity$3.12{\pm}0.75$ PG/tube ($mean{\pm}SD$)였고, lntra-assay precision(CV%) 9.52 (20 replicates;$38.4{\pm}3.66$nmol/1) 와 8.81 (15 replicates; $102.4{\pm}8.82$nmol/1)였다. Inter-assay precision(CV%) 은 11.9 (mean of 4 pools-7.03, 23.16, 52.11 과 117.53 nmol/1)로 2개월 동안에 걸쳐 시행되었고, 평균 비이어스(mean bias)는 -0.78 로 28에서 448 nmol 범위로서 매일아침 "뇨"의 차이분(different aliquots)은 좋은 결과를 얻었다. 건강한 여성으로부터 채취된 뇨중 Oestrone-3-glucuronide 의 농도(nmol/1)를 보면 월경주기의 여포기와 배난기 및 황체기에 있어서 각기 $40.2{\pm}9.9$ , $102.3{\pm}39.4$$84.3{\pm}13.3$nmol/1였다. 이와같은 결과는 동일한 검사뇨를 방사면역학적 방법(RIA)으로 측정 (6 menstrual cycle)한 결과와 유사한 측정치를 얻으므로서 간편하고 진보된 좋은 방법중의 하나라고 사료되는바이다.

  • PDF

간섭식 적외선 분광기에 의한 태백지역 석탄광의 호흡성 분진 중 석영, 운모 및 장석의 정량분석 (Quantitative Analysis of Quartz, Mica, and Feldspar in Respirable Coalmine Dust in Taebaek Area by Fourier Transform Infrared Spectrophotometry)

  • 최호춘;천용희;김해정;이정주
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권2호
    • /
    • pp.271-283
    • /
    • 1988
  • A Fourier transform infrared spectrophotometric method was described for the determination of quartz, mica(sericite) and feldspar(potassium feldspar) in respirable dust in Taebaek area. The results were as follows; 1) The concentration of minerals were determined from the intensity of absorption peak of quartz at $799cm^{-1}$, sericite at $539cm^{-1}$, and potassium feldspar at $648cm^{-1}$ respectively. 2) The precision(C. V. %) for the quartz determination was $7.70{\pm}2.68%$ from 10 to $200{\mu}g$ of quartz. 3) The precision for the sericite determination was $16.34{\pm}6.82%$ from 30 to $500{\mu}g$ of serictite. 4) The precision for the potassium feldspar determination was $5.28{\pm}1.74%$ from 30 to $500{\mu}g$ of potassium feldspar. 5) The concentration of respirable dust in Taebaek area was $4.90{\pm}3.29mg/m^3$ (0.4-93.7%), percent quartz was $1.80{\pm}4.14%$ (0.01-20.56%), percent sericite was $11.37{\pm}6.43%$ (0.00-29.69%), percent potassium feldspar was 8.15% (n=7, 3.41-19.70%). 6) The difference of respirable coal dust, quartz, and sericite concentrations in drilling, coal cutting, hauling and seperating was significant respectively (p<0.05).

  • PDF

경락 임피던스 측정 시스템 개발에 관한 연구 (Study on the Development of Meridian Impedance Measurement System)

  • 이우철;인창식;민경기
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

쥐에서 이중에너지 방사선 흡수법을 이용한 골밀도의 측정: 다양한 골부위에서 재위치 여부에 따른 생체내 측정의 정밀도 (Bone Mineral Density Measurement of Rats Using Dual-energy X-ray Absorptiometry: Precision of In Vivo Measurements for Various Skeletal Sites with or without Repositioning)

  • 오동현;정재호;우상근;천기정;김병일;최창운;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권1호
    • /
    • pp.72-78
    • /
    • 2009
  • 목적: 살아있는 쥐를 실험대상으로 DXA를 이용하여 검사사이마다 자세변화가 있는 경우와 자세변화 없는 경우에 다양한 부위의 골밀도를 반복적으로 측정하여 각 개체의 자세 변화와 측정부위에 따른 정밀도에 차이가 있는지를 평가하고자 하였다. 대상 및 방법: 실험은 총 12마리의 수컷 쥐를 대상으로 하였다. 아이소후루란(isoflurane)을 이용한 흡입 마취하에 DXA 기기와 기기에 내장되어 있는 소동 물 프로그램(software)를 이용하여 쥐들을 스캔하였다. 스캔 후 얻어진 영상에서 오른쪽 뒷다리(hind limb), 요추(lumbar spine), 두개골(skull) 그리고 골반골(pelvic bones)에 각각 관심영역(ROI)을 그려서 골밀도($g/cm^2$) 값을 구하였다. 실험에 포함된 12마리 쥐 모두에 대해서는 처음 스캔 테이블에 올린 자세를 유지한 상태 그대로 반복해서 4번씩의 스캔을 시행하였다(그룹 1a). 그리고 일주일 후에는 12마리 중 6마리에 대해서만 검사를 시행하였고 한번의 스캔 후 쥐를 테이블에서 완전히 내렸다가 다시 스캔 테이블로 올려서 자세를 잡고 스캔을 반복하는 방식으로 스캔 사이사이마다 새롭게 자세를 잡고 검사를 시행하였다(그룹 2). 자세변화유무와 상관없이 각각의 그룹 내에서의 부위별 정밀도의 차이는 Kruskal-Wallis one-way analysis of variance(ANOVA) test로 비교하였으며 자세변화에 따른 그룹간에 부위별 정밀도의 차이는 그룹 1의 12마리 중 그룹 2에 해당하는 6마리(그룹 1b)와 그룹 2를 Wilcoxon Signed Rank Sum Test로 비교하였으며 얼마나 일관성이 있는지 Bland Altman 도표분석을 하였다. 결과: 각각의 그룹 내에서 측정 부위에 따라 정밀도의 차이는 그룹 1a는 유의한 차이가 없었으나(p=0.657) 그룹 2의 경우 정밀도에 유의한 차이가 있었다(p=0.003). 그룹간에 부위별 정밀도는 차이는 오른쪽 뒷다리가 p=0.173, 제1-4 요추가 p=0.600 두개골이 p=0.046 그리고 골반골이 p=0.075로 두개골을 제외한 모든 부위에서 검사간 자세변화 따른 정밀도의 차이가 통계적으로 유의하지 않았다. 또한 Bland Altman도표에서 자세변화에 따른 두 그룹의 부위별 측정값의 차이에 치우침은 두개골을 제외한 모든 부위에서 없었으며 차이의 2표준편차는 오른쪽 뒷다리가 2.3%, 제1-4요추가 5.9%, 두개골이 4.4% 그리고 골반골이 3.0%이었다. 결론: 본 연구에서 재위치를 시행한 그룹 내에서 부위에 따른 정밀도의 차이는 나타났지만 재위치 유무에 따른 각 부위의 정밀도는 두개골을 제외한 나머지 부위들에서는 유의한 차이를 없었다. 결론적으로 본 연구의 결과는 DXA는 쥐와 같은 살아있는 소동물에서 다양한 부위에 대해 반복적으로 골밀도 값을 측정하고 추적관찰 할 때 자세의 재위치에 상관없이 충분한 정밀도를 가지고 있으며 골밀도를 평가하는데 있어서 매우 믿을만한 검사라는 것을 시사한다.

Alpha feto protein(AFP)검사 키트의 유효성 평가실험 (Evaluation of the Kit's Efficiency of Alpha Fetoprotein (AFP) Test)

  • 조현수;노경운;유태민
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.101-104
    • /
    • 2018
  • Purpose Alpha fetoprotein(AFP) is a fetal serum protein that increases in germ cell tumors derived from liver cancer or egg yolk. AFP test has been used for screening of liver cancer, determination of tumor stage, determination of therapeutic effect, and fetal congenital malformations. The purpose of this study was to compare the results of the four kits, identify the advantages and disadvantages of each kit, and select the appropriate kits for our laboratory. Materials and Methods Blood samples were obtained from 89 patients attending the Seoul national university hospital. Experiments were carried out in accordance with manufacturer's instructions of four companies(A, B, C, D). The precision, recovery, linearity, and sensitivity test were performed for each kit. Results In case of the precision within the measurement, the CV value of the C kit was less than 5% at the low, middle, and high concentrations. The A, B and D kit's the CV value was less than 5% at the concentrations except the low concentration. The recovery rates of the A, B, C, and D kits were $100{\pm}15%$, $100{\pm}30%$, $100{\pm}16%$ and $100{\pm}14%$, respectively. All kits showed good linearity. Sensitivity was measured as 0.5 IU/mL for A, 0.4 IU/mL for B, 0.98 IU/mL for C, and 0.3 IU/mL for D. Conclusion The CV values of the four kits were within 10%, and the correlation coefficients were close to 1 for $R^2=0.978$, $R^2=0.992$ and $R^2=0.8957$. As a result, they are clinically available. Therefore, each laboratory should select the appropriate kit for their experiment's environment.

방사능 측정기를 이용한 F-18 FDG 방사능의 비교 (Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements)

  • 진계환;권대철;오기백;박훈희;김정열;박민수;박대성
    • 한국의학물리학회지:의학물리
    • /
    • 제20권3호
    • /
    • pp.159-166
    • /
    • 2009
  • 국내병원에 설치된 PET와 PET/CT의 영상품질관리와 방사능 피폭을 효과적으로 관리하기 위해서는 환자에게 투여하는 F-18 FDG 방사능 측정에 사용하는 방사능 측정기에 따른 정도관리가 필요하다. F-18 FDG의 정확도와 정밀도를 방사능 측정기로 방사능을 측정하기 위해 시료제조 및 방사능을 측정하였다. F-18 FDG의 방사능 측정에 사용하는 방사능 측정기의 정확도와 정밀도를 파악하여 방사능 측정기에서 측정한 방사능을 보정하였다. 국내 의료기관의 PET 시스템 10대를 시간간격으로 측정하여 한국표준과학원에서 측정한 방사능을 기준 값으로 병원에서 측정한 방사능과 비교하여 정확도와 정밀도를 산출하였다. 정확도를 이용하여 팬텀에 주입하는 방사능을 보정함으로써 팬텀에 주입하는 방사능량에 대한 신뢰성을 확보하였다. F-18 FDG의 방사능 측정기의 정확도는 -5.00%에서 +4.50%, 정밀도 0.05%에서 0.45%으로 국제기준인 정확도 ${\pm}$10%, 정밀도 ${\pm}$5%를 모두 만족하였다. PET/CT 시스템들에 대한 정량적 비교 분석 자료는 PET/CT의 진단율을 높이는 효과가 기대된다.

  • PDF

Haemophilus influenzae type b 피막 다당질 특이 인간 IgG 항체의 정량적 측정을 위한 enzyme immunoassay의 타당성 연구 (Validation of enzyme immunoassay for the quantitative measurement of human IgG antibodies specific for Haemophilus influenzae Type b capsular polysaccharide)

  • 김경효;임수영
    • Clinical and Experimental Pediatrics
    • /
    • 제50권2호
    • /
    • pp.143-150
    • /
    • 2007
  • 목 적: 인체의 항 PRP IgG 항체를 정량적으로 측정하기 위한 방법인 표준화된 효소면역법의 타당성을 연구하는 것이 목적이다. 방 법: 인체의 항 PRP IgG 항체를 정량적으로 측정하기 위한 방법인 표준화된 효소면역법의 타당성을 연구하기 위해 특이성, 반복성, 실험실내 정밀성, 정확성, 최소 정량 한계, 및 안정성을 평가하였다. 결 과: 본 연구에서 사용한 효소면역법은 검사에 사용된 항원(HbO-HA)에 특이성을 보였으며 반복성, 실험실내 정밀성 등의 정밀성은 허용기준(반복성 : $CV{\leq}15%$, 실험실내 정밀성 : $CV{\leq}20%$)을 만족하였다. 정확성은 28개 혈청을 대상으로 한 RABA 정량결과와 효소 면역법 정량결과 비교시험에서 높은 상관계수를 보였고 첨가 회복 검사 결과 허용기준($100{\pm}20%$)을 만족하였다. 최소 정량 한계 시료 정량결과의 정밀성과 정확성은 공칭 양의 -14.7~-4.7%로 모두 허용기준(정밀성 : $CV{\leq}25%$, 정확성 : ${\pm}25%$)을 만족하였다. 안정성 중 냉 해동 안정성과 단기 온도 안정성도 모두 허용기준(${\pm}20%$ 이내)을 만족하였다. 결 론: 이상의 결과로 이화여자대학교 의과학연구소 백신효능연구센터에서 시행한 본 효소 면역법은 혈액 내에 존재하는 항 PRP IgG 항체를 정량적으로 측정하는 시험법으로 적절하였다.