• 제목/요약/키워드: Pre-coagulation

검색결과 79건 처리시간 0.021초

재활용을 위한 양돈폐수와 공정슬러지의 특성연구 (Study on Characteristics of Piggery Waste and Processing Sludge for Reuse)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.308-313
    • /
    • 2006
  • Charicteristics of piggery waste and treatment processing sludges for reuse were investigated. If it was thoroughly regulated in disinfectants, antibiotic substances and heavy metals, raw piggery waste can be gratified in criteria for fermentative compost (liquid) for flowers cultivation. Also, Because it is satisfied with various criteria of heavy metals and fertilizer contents for reuse except water content, primary pre-treatment sludge is very good material for composting. If provated goods on heavy metals are used in coagulation & dewatering process, coagulation & dewatering sludges are suitable for criteria of special waste regulation and by-product compost. This study proves that, if they are accomplished with suitable composting and mature process, piggery waste and processing sludges are free from microbiological problems as well as criteria of composting.

최적 응집 효율을 위한 Al계 액상 응집제의 희석 효과 (The Predilution Effect of Al-based Liquid Coagulants for the Optimal Efficacy)

  • 허재용;이상화
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.37-43
    • /
    • 2006
  • 원수의 pH, 응집제의 주입량, 희석배수에 따라 알루미늄계 응집제(Alum, PACS, PACC)의 원수내 인과 탁질의 제거효과를 고찰하였다. 저탁도(20 NUT) 및 적정 pH 6~9하에서 알류미늄계 응집제간의 탁도 제거율의 차이는 뚜렷하게 나타나지 않았다. 그러나 인의 제거율에 있어서는 20~40 ppm의 주입량에 대해서 응집제의 염기도가 증가할수록 감소함을 알 수 있었다. Alum (0%)>PACS (45~50%)>PACC (70%), 고탁도(100 NUT) 하에서는 고분자 응집제인 PACS와 PACC의 응집성능이 단분자 응집제인 Alum보다 뛰어남을 알 수 있었다. 20 NUT의 저탁도에서 직접 주입한 경우와 비교해서, 500~2000배로 희석한 Alum의 경우에는 응집효율의 감소가 나타났으나 희석된 응집제의 체류시간이 증가함에 따라 탁도 및 인의 제거율이 증가하는 경향을 나타내주었다. 반면에 희석된 PACC의 경우에는 분산도의 증가에 기인한 응집성능의 향상이 나타났으나 희석된 응집제의 체류시간이 증가함에 따라 응집효율의 감소가 나타났다. 100 NTU의 고탁도 조건하에서는 Alum과 PACC를 희석하여 주입시 모두 응집성능이 향상됨을 알 수 있었다.

$MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명 (Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process)

  • 손희종;황영도;노재순;정철우;강임석
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.753-761
    • /
    • 2005
  • 전처리 공정에 따른 투과 flux 변화를 살펴보면 $MIEX^{(R)}$+UF 공정의 경우 응집+UF 공정에 비하여 높은 유기물 제거율을 나타내었으나 투과 flux 감소는 크게 나타났다. 따라서, 막 오염을 자세하게 규명하기 위하여 sequential filtration 실험결과 막 오염물질은 고분자 유기물질로 나타났으며, DOC 0.5 mg/L 이하의 유기물질이 막 오염 유발물질로 작용하고 있었다. 10 kDa 이하의 저분자 유기물질들은 $MIEX^{(R)}$ 처리에 의해 제거가 용이하여 막 표면에서 유기물 부하를 감소시켜 이로 인해 응집+UF공정에 비하여 투과 flux 감소율이 낮게 나타났다. $MIEX^{(R)}$+UF공정은 입자상 물질의 존재 유무에 관계없이 flux 감소율은 거의 유사한 경향을 보였으나 응집+UF공정은 용존성 유기물질만이 존재하는 시수에 비하여 입자상 물질이 존재하는 경우에 투과 flux 감소가 더 낮게 나타났다.

지르코늄 실리케이트를 응집보조제로 이용한 응집공정에 관한 연구 (A Study on Coagulation Process using Zirconium Silicate as a Coagulation-aid)

  • 조재성;윤태일;전유재;조경철
    • 대한환경공학회지
    • /
    • 제31권3호
    • /
    • pp.203-207
    • /
    • 2009
  • 최근 산업화에 따른 다양한 신종 미량유해물질의 등장과 지속적인 오염물질의 증가로 수질오염의 심각성과 그 위해성에 대한 관심이 커지고 있다. 특히 응집공정을 통하여 유기오염물질 제거를 좀 더 효율적으로 증가시킬 수 있는 방법들이 모색되고 있다. 본 연구는 도시하수 및 호소수를 대상으로 실험하였다. 응집공정에 사용하기 위해 응집 보조제로서 사용될 수 있는 지르코늄 실리케이트($ZrSiO_4$)의 특성을 연구 하였다. 응집공정에서의 지르코늄 실리케이트의 주입방법에 따른 유기물 제거율을 PDA (Photometric Dispersion Analyzer)를 통하여 평가하였다. 지르코늄 실리케이트는 pH 7에서 zeta-potential이 -32.22 mv였고 산성에 가까울수록 낮은 음(-)전하 값을 보였으며 지르코늄 실리케이트를 주입하지 않은 도시하수보다 주입하였을 때 $UV_{254}$ 값이 더 높은 특성을 나타내었다. 또한 PDA실험을 통하여 확인한 결과 지르코늄 실리케이트의 주입은 floc의 성장을 도와주는 것을 확인할 수 있었다. Alum을 이용한 응집공정에 대한 지르코늄 실리케이트의 주입방법을 선 주입, 동시 주입, 후 주입의 3가지 방법으로 실험을 수행하였다. 실험 결과 Alum과 지르코늄 실리케이트를 함께 주입한 경우 Alum을 단독으로 주입한 경우보다 유기물 제거율이 15% 이상 증가하였다. 특히 Alum 20 mg/L과 지르코늄 실리케이트 10 mg/L를 함께 사용한 경우 90% 이상의 높은 유기물제거율을 보였다. PAC (Poly Aluminium Chloride)와 PACS (Poly Aluminium Chloride Silicate)를 응집제로 이용하는 경우에도 지르코늄 실리케이트를 함께 주입 시 $COD_{Cr}$의 제거효율이 15% 이상 향상되었다. 결과적으로 지르코늄 실리케이트를 응집제와 동시에 주입한 방법이 전, 후로 주입한 경우보다 $COD_{Cr}$ 제거효율이 5~10% 높게 나타났으나, 용존성 물질은 시주입 시, 더 낮은 제거효율을 보였다.

도시의 분산형 생활오수 재생시스템에 화학적 전처리공정도입에 관한 연구 (A Study on the Application of Pre-Chemical Treatment on the Decentralized Domestic Wastewater Reclamation System)

  • 이상우;박영미;서규태
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.115-121
    • /
    • 2006
  • The purpose of this study was to investigate applicability of pretreatment on the existing biological treatment for domestic wastewater reclamation. From Jar Tests, it was found that optimum dosage of coagulant was PAC 0.5mg/L and $FeCl_3$ 180mg/L for urban sewage. In this study, PAC 0.5mg/L was selected considering sludge production and the amount of coagulant required. In a continuous experiment performed with combining chemical coagulation and biological treatment, a considerable removal efficency was obtained in term of BOD, SS, T-N, T-P and ABS. When the raw sewage was supplied into the pre-chamical treatment facility, the removal of BOD and SS was 48.3% and 81.1%. However T-N removal was very low which means T-N consists of $NH_3-N$ mostly. T-P was almost completely recluced by the chemical addition. The effluent BOD & SS was 57~76 and 21~43mg/L, which could reduce the size of biological treatment facility. From the cost estimation pre-chemical treatment could save around half of the area required for biological treatment with post ceagulation.

고탁도시 DAF 정수장의 운영 및 진단 (Operation and Diagnosis of DAF Water Treatment Plant at Highly Turbid Raw Water)

  • 권순범;안효원;강준구;손병용
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.191-200
    • /
    • 2004
  • DAF process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when the freshwater blooms occut or raw water turbidity become high. Pre-sedimentation iS prepared in case when raw water turbidity is very high by rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while it is difficult to remove in sedimentation. One of the main concerns in adoption of DAF (Dissolved Air-Flotation) process is a high raw water turbidity problem. That is, DAF is not adequate for raw water, which is more turbid than 100NTU. In order to avoid this problem, pre-sedimentation basins are prepared in DAF plant to decrease the turbidity of DAF influent. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, DAF process coupled with sedimentation is suggested that pre-sedimentation with optimum coagulation prior to DAF would be appropriate.

분리막을 이용한 정수처리 System에서 처리공정 및 운전조건의 최적화에 관한연구 (A Study on the Opimization of Process and Operation Condition for Membrane System in Tap Water Treatment)

  • 오중교
    • 멤브레인
    • /
    • 제9권4호
    • /
    • pp.193-201
    • /
    • 1999
  • 기존의 정수처리 공정인 응집 침전 과정을 대체하여 분리막을 이용한 상수처리 시스템의 개발을 목적으로한다. 따라서 4가지 형태의 정수처리 공정과 분리막의 분획 분자량을 변화시켰을 때 막 투과수의 변화와 안정적이며 높은 투과수를 얻기 위해 필요한 운전 조건의 최적화를 실험하였다 실험결과 한외여과막이 정밀여과막보다 막 투과수 감소경향이 완만했으며 초기 투과수 회복율은 더 높았다. 수질 분석의 결과 한회여과막이 정밀 여과막보다 우수하였지만 전처리에 의한 차이는 나지 않았다. 운전 조건에 따른 flux 는 온도, 선속도가 높을수록 압력이 낮을수록 flux 감소율이 적은 경향을 나타내었다.

  • PDF

A study on boron removal for seawater desalination using the combination process of mineral cluster and RO membrane system

  • Cho, Bong-Yeon;Kim, Hye-Won;Shin, Yee-Sook
    • Environmental Engineering Research
    • /
    • 제20권3호
    • /
    • pp.285-289
    • /
    • 2015
  • Complicated and expensive seawater desalination technology is a big challenge in boron removal process. Conventional seawater desalination process of coagulation utilized for pre-treatment is difficult to remove boron. Boron can be removed more effectively in Reverse Osmosis (RO) process than any other processes. In this study, a coagulant with the name Mineral Cluster was examined its boron removal ability. Boron removal efficiency of Mineral Cluster depended on pH value and Mineral Cluster dosage. Desalination process combines the pre-treatment process with Mineral cluster diluted at the ratio of 1:2500 and the RO membrane process. The original sea water could be desalinated to drinking water quality, 1 mg/L, without any pH adjustments. Therefore, if the Mineral cluster is added without any other chemicals for adjusting pH, the desalination process would be much safer, efficient and economical.

하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구 (A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent)

  • 최충호;맹승규;심재휘;최진호;송경근;이병하;차호영
    • 한국물환경학회지
    • /
    • 제28권5호
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

에폭시수지 생산 공정에서 발생되는 brine 폐수의 전처리를 위한 응집 및 침전 반응의 최적화 연구 (A Study on The Optimization of Pre-treatment for the Brine Wastewater from the Epoxy-resin Process by the Coagulation and Sedimentation Reactions)

  • 조욱상;이은영;강성욱;이장수;진수익
    • 청정기술
    • /
    • 제11권2호
    • /
    • pp.57-67
    • /
    • 2005
  • 에폭시 수지는 ECH(Epichlorohydrin)와 BPA(Bisphenol-A)를 원료로 가성소다 존재 하에 탈수응축 반응을 통해 생성되며 반응 부산물로 소금물이 폐수로 발생되는데 이를 Brine이라 부르며 글리시돌과 같은 에멀젼 상태의 ECH 유도체와 수지성 폴리머를 함유하는 알카리성 폐수이다. 이러한 폐수는 폐수처리 과정에서 반응기 내부와 배관 내벽에 폴리머 입자가 침적 및 응고되어 plugging을 일으키는 등 전체적으로 후처리 공정에서 fouling 현상이 발생되고 있는데 이는 미생물의 분해 활성도를 급격히 떨어뜨려 폐수처리 효율이 낮아지는 문제점을 야기 시키고 있다. 본 연구에서는 무기 응집제와 유기 고분자 응집제를 이용하여 에폭시 수지 생산 공정에서 발생하는 brine 폐수에 존재하는 ECH 유도체와 수지성 폴리머를 반고상 슬러지 형태로 응집 및 침전시킴으로써 fouling 현상을 일으키는 요인을 제거하고자 최적의 응집반응 조건을 도출하였고 경제성 분석 등 이를 실제 공정에 적용할 수 있는 방안을 제시하고자 하였다.

  • PDF