• 제목/요약/키워드: Pre-Conditioning

검색결과 132건 처리시간 0.033초

기존단독주택의 에너지절약을 위한 개수방안연구 (Study on Retrofit Measures for Energy Conservation in Existing Residence)

  • 박상동;박효순;유헌형;민창현
    • 대한설비공학회지:설비저널
    • /
    • 제11권3호
    • /
    • pp.31-51
    • /
    • 1982
  • For studying this project, we selected a 2-storied detached house as a sample which was constructed in July 1976, the last year of the 3rd 5-years economic and social development plan and also the middle year between the years of the 1st oil crisis and the 2nd oil crisis, located In Gayang-dong, Daejeon City. The contents and scope of this project was to produce retrofit measures by theoretically analyzing the building energy use between both of pre-retrofit and post-retrofit conditions of this sample house, and to compare and analyze the predicated data with experimented data under post - retrofit condition. It is suggested in this report that we have to develop rational and practical retrofit measures for energy conservations in existing residences.

  • PDF

A New Photovoltaic System Architecture of Module-Integrated Converter with a Single-sourced Asymmetric Multilevel Inverter Using a Cost-effective Single-ended Pre-regulator

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.222-231
    • /
    • 2017
  • In this paper, a new architecture for a cost-effective power conditioning systems (PCS) using a single-sourced asymmetric cascaded H-bridge multilevel inverter (MLI) for photovoltaic (PV) applications is proposed. The asymmetric MLI topology has a reduced number of parts compared to the symmetrical type for the same number of voltage level. However, the modulation index threshold related to the drop in the number of levels of the inverter output is higher than that of the symmetrical MLI. This problem results in a modulation index limitation which is relatively higher than that of the symmetrical MLI. Hence, an extra voltage pre-regulator becomes a necessary component in the PCS under a wide operating bias variation. In addition to pre-stage voltage regulation for the constant MLI dc-links, another auxiliary pre-regulator should provide isolation and voltage balance among the multiple H-bridge cells in the asymmetrical MLI as well as the symmetrical ones. The proposed PCS uses a single-ended DC-DC converter topology with a coupled inductor and charge-pump circuit to satisfy all of the aforementioned requirements. Since the proposed integrated-type voltage pre-regulator circuit uses only a single MOSFET switch and a single magnetic component, the size and cost of the PCS is an optimal trade-off. In addition, the voltage balance between the separate H-bridge cells is automatically maintained by the number of turns in the coupled inductor transformer regardless of the duty cycle, which eliminates the need for an extra voltage regulator for the auxiliary H-bridge in MLIs. The voltage balance is also maintained under the discontinuous conduction mode (DCM). Thus, the PCS is also operational during light load conditions. The proposed architecture can apply the module-integrated converter (MIC) concept to perform distributed MPPT. The proposed architecture is analyzed and verified for a 7-level asymmetric MLI, using simulation results and a hardware implementation.

128채널 심장전기도 시스템의 증폭기 설계 (The design of amplifier for 128 channels Cardiac-activation system)

  • 한영오
    • 한국컴퓨터산업학회논문지
    • /
    • 제8권2호
    • /
    • pp.123-130
    • /
    • 2007
  • 본 논문에서는 신호조정 회로로서 필수적인 다중 채널 심장 전기도 전치 증폭기를 제작하기 위한 설계조건의 분석 및 전기 회로적 해석을 수행하였다. 설계된 회로는 기존의 64 채널의 공간 분해능을 향상시키기 위하여 128채널로 구성하였으며, 전치증폭기는 입력회로부, 차동증폭부, 오른다리구동회로 및 주증폭기의 노치필터로 구성되도록 설계하였다.

  • PDF

경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성 (Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Status of Czech Low and Intermediate Radioactive Waste Management in the Context of European Development

  • Trtilek, Radek;Havlova, Vaclava;Podlaha, Josef;Svoboda, Karel;Otcovsky, Tomas
    • 방사성폐기물학회지
    • /
    • 제19권1호
    • /
    • pp.29-38
    • /
    • 2021
  • The article summarises the status and competence of UJV Rez, a. s. (up to 2012, the Nuclear Research Institute Rez, Czech Republic) in the field of radioactive waste (RAW) management as a company managing of 95% of institutional radioactive wastes in Czech Republic. UJV Rez a. s. has been one of the Czech Republic's key research and engineering institutions in the field of nuclear energy production since 1955. The company processes and conditions prior to storage 95% of so-called institutional RAW and is the principal partner of the state with respect to the research support of the Czech deep geological repository development project. UJV Rez a. s. boasts its own accredited radiochemical analytical test laboratory, unique of its kind in the Czech Republic. Of equal importance is UJV Rez's active participation in a range of international organisations and associations and its involvement in wide range of international projects, and so as European projects. One of them is EU funded project PREDIS: Pre-disposal management of radioactive wastes, that has started at September 2020, focused on the field of low level radioactive waste (LLW) and intermediate level radioactive waste (ILW) pre-disposal.

Effect of Preconditioning Ischemia on Endothelial Dysfunction Produced by Ischemia-Reperfusion in Rabbit Coronary Artery

  • Suh, Suk-Hyo;Park, Yee-Tae;Kim, Woong-Heum;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • 제29권1호
    • /
    • pp.51-59
    • /
    • 1995
  • This study was designed to test whether or not 1) ischemia-reperfusion attenuates endothelium-dependent relaxation of coronary arteries and 2) preconditioning protects the arterial endothelium from ischemia-reperfusion injury. In anesthetized open chest rabbits, branches of the left circumflex artery were exposed to different combinations of the experimental conditions; ischemia (15 minutes), ischemia (15 minutes)-reperfusion (10 minutes), preconditioning ischemia, and pre-conditioning fellowed by ischemia-reperfusion. Preconditioning consisted of 3 occlusions of 2-min duration, each followed by n 5-min reperfusion. Rings of the artery exposed to the experimental condition and of normal left anterior descending coronary artery were prepared and suspended for isometric force measurement in organ chambers containing Krebs Ringer bicarbonate solution. The rings were contracted with 29.6 mM KCI. Ischemia alone did not attenuate endothelium-dependent relaxation by acetylcholine. However, ischemia-reperfusion significantly impaired endothelium-dependent relaxation. Endothelium-independent relaxation by sodium nitroprusside was not impaired by ischemia-reperfusion and the constrictive response to acetylcholine was not altered in reperfused rings without endothelium, compared with control rings. Arterial rings exposed to preconditioning followed by ischemia-reperfusion exhibited impaired endothelium-dependent relaxation by acetyl-choline. However, although preconditioning not fellowed by ischemia-reperfusion, attenuated endothelium-dependent relaxation at low concentrations of acetylcholine, the magnitude of the impairment by preconditioning followed by ischemia-reperfusion was significantly less than that of the impairment by ischemia-reperfusion alone. These data demonstrate that ischemia-reperfusion significantly attenuates endothelium-dependent relaxation by producing endothelial dysfunction and preconditioning Protects the endothelium of coronary arteries from ischemia-reperfusion injury.

  • PDF

Graphic Simulator for Analyzing the Remote Operation of the Advanced Spent Fuel Conditioning Process

  • Song, Tai-Gil;Kim, Sung-Hyun;Lee, Jong-Ryul;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1319-1322
    • /
    • 2003
  • KAERI is developing the Advanced Spent Fuel Conditioning Process (ACP) as a pre-disposal treatment process for spent fuel. Equipment used for such a spent fuel recycling and management process must operate in intense radiation fields as well as in a high temperature. Therefore, remote maintenance has a played a significant role in this process because of combined chemical and radiological contamination. Hence suitable remote handling and maintenance technology needs to be developed along with the design of the process concepts. To do this, we developed the graphic simulator for the ACP. The graphic simulator provides the capability of verifying the remote operability of the process without fabrication of the process equipment. In other words, by applying virtual reality to the remote maintenance operation, a remote operation task can be simulated in the graphic simulator, not in a real environment. The graphic simulator will substantially reduce the cost of the development of the remote handling and maintenance procedure as well as the process equipment, while at the same time producing a process and a remote maintenance concept that is more reliable, easier to implement, and easier to understand.

  • PDF

Application of the Digital Mockup to Preliminary Analysis the Remote Maintainability of ACP

  • Song, Tai-Gil;Kim, Sung-Hyun;Park, Byung-Suk;Yoon, Ji-Sup;Lee, Sang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.363-366
    • /
    • 2004
  • KAERI is developing the Advanced Spent Fuel Conditioning Process (ACP) as a pre-disposal treatment process for spent fuel. In this process, the management process must operate in intense radiation fields as well as in a high temperature. Therefore, remote maintenance has played a significant role in this process. Hence suitable remote handling and maintenance technology needs to be developed along with the design of the process concepts. To do this, we developed the digital mockup for the ACP. The digital mockup provides the capability of verifying the remote operability of the process without fabrication of the process equipment. In other words, by applying virtual reality to the remote maintenance operation, a remote operation task can be simulated in the digital mockup. Through utilizing this graphic simulation in this digital mockup, general guidelines can be established for designing equipment intended for remote handling and maintenance. Also, the designer of the equipment that must be remotely maintained should ensure that there is adequate access to the process equipment. The graphic simulator will substantially reduce the cost of the develo363pment of the remote handling and maintenance procedure as well as the process equipment.

  • PDF