• Title/Summary/Keyword: Pre-Breakdown

Search Result 79, Processing Time 0.025 seconds

Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures ($SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성)

  • Lee, Bok-Hee;Oh, Sung-Kyun;Baek, Young-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF

The Application of Pre-Breakdown Partial Discharge Detection Method for Breakdown of Investigation of Long Distance XLPE Cable (장조장 XLPE 케이블 절연 파괴 원인 규명을 위한 전구차단 장치의 응용)

  • Lee, C.Y.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1827-1829
    • /
    • 2002
  • This paper describes AC test for long delivered drum length of cable using pre-breakdown partial discharge detection(PPD) method, which can be applied to observe the causes of electrical breakdown of EHV XLPE insulation. This method is to de-energize applied voltage to cable rapidly using pre-breakdown partial discharge, and is able to prevent complete breakdown. By this effect, defects such as voids, metal particles and protrusion in cable can be observed clearly. AC resonant test set was used for PPD method. Localization of partial discharge was performed by time difference detection of the traveling wave. Accuracy of localization was 1% to the length of test cable. Through several experiments with XLPE cable, successful results of PPD method were obtained.

  • PDF

The breakdown characteristics of $N_2$ gas with lightning impulse voltage in the non-uniform electrode (불평등전극계에서 뇌임펄스전압에 대한 $N_2$기체의 절연파괴 특성)

  • Lee, Bok-Hee;Lee, Feng;Joe, Jeong-Hyeon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presents the experimental results on breakdown characteristics in $N_2$ gas under non-uniform electric fields caused by both the positive and negative lightning impulse voltages. $N_2$ gas have an advantage of eco-friendly and cost reduction, and safety aspects. In order to analyze the impulse pre-breakdown processes in $N_2$ gas, we carried out measurements and observations of the impulse breakdown voltages, pre-breakdown current and luminous signals. They were measured by a voltage divider, a shunt and a photo-multiplier tube, respectively. Additionally, the characteristics of discharge channels were observed by high speed cameras. The breakdown voltages in the positive polarity was lower than those in the negative polarity.

  • PDF

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

Discharge Characteristics near the tip of needle in water (수중에서 침전극 끝단의 방전특성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Jun, Byung-Wook;Kim, Hoe-Gu;Beak, Young-Hwan;Lee, Kyu-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.239-241
    • /
    • 2007
  • In this paper we describe streamer propagations characterizing underwater pre-breakdown and breakdown behaviour under impulse voltages. Streamer corona branches in lower resistivities are much thicker and brighter than those in higher resistivities. The negative streamer channels not only have more branches but also widely spread out than the positive streamer channels. The succession of streamer coronas during re-breakdown produces a stepwise propagation. The pre-breakdown currents consist of the conduction current and streamer corona current pulses.

  • PDF

Underwater Discharge Phenomena in Inhomogeneous Electric Fields Caused by Impulse Voltages

  • Lee, Bok-Hee;Kim, Dong-Seong;Choi, Jong-Hyuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.329-336
    • /
    • 2010
  • The paper describes the electrical and optical properties of underwater discharges in highly inhomogeneous electric fields caused by 1.2/50 ${\mu}s$ impulse voltages as functions of the polarity and amplitude of the applied voltage, and various water conductivities. The electric fields are formed by a point-to-plane electrode system. The formation of air bubbles is associated with a thermal process of the water located at the tip of the needle electrode, and streamer coronas can be initiated in the air bubbles and propagated through the test gap with stepped leaders. The fastest streamer channel experiences the final jump across the test gap. The negative streamer channels not only have more branches but are also more widely spread out than the positive streamer channels. The propagation velocity of the positive streamer is much faster than that of the negative one and, in fact, both these velocities are independent of the water conductivity; in addition the time-lag to breakdown is insensitive to water conductivity. The higher the water conductivity the larger the pre-breakdown energy, therefore, the ionic currents do not contribute to the initiation and propagation of the underwater discharges in the test conditions considered.

Development of Pre-breakdown Partial Discharge Detection Method for Explanation of the Cause of EHV XLPE Cable Joint Breakdown (절연파괴 원인규명을 위한 Pre-breakdown PD 검출기술 개발)

  • Kim, Choong-Sik;Kim, Young-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.85-86
    • /
    • 2008
  • 케이블의 원가절감을 위해 절연체의 절연두께를 줄이거나 초초고압화가 되어 갈수록 절연성능의 신뢰성 향상이 한층 요구되고 있다. 이를 위해 케이블 및 접속함의 절연체 내에 각종의 결함이 어느 정도 절연성능을 떨어뜨리는지 정량적으로 파악하여 개선할 필요가 있다. 또한 완제품 내 잔족하고 있는 이물의 종류 및 위치를 알 수 있으면 생산공정 내에서 이물 유입 경로를 파악하여 이물이 유입되는 것을 차단할 수 있다. AC내전압 파괴시험을 수행할 때 설계치 보다 저전계에서 파괴될 경우 파괴공을 조사하여 원인을 규명하고자 하지만 국부적인 결함으로 인한 파괴는 결함부를 소실시키기 때문에 파괴공 및 주위의 절연체를 현미경으로 관찰하여도 찾기가 어렵다. 따라서, 전원을 고속으로 차단하여 결함부가 완전히 소손되는 것을 막고 PD발생 위치를 추정하여 결함을 확인하는 방법이 요구 되어진다. 이러한 시험 방법을 전구차단법 이라고 하며, 고도의 PD측정기술과 판정기술이 필요한 종합적인 기술이다. 본 논문에서는 PPD 기술의 핵심인 노이즈 제거 기술과 판별기술을 서술하고 실제 접속함(PMJ)에 적용하여 PPD 기술의 유효함을 증명하였다.

  • PDF

Adhesion properties and Breakdown behaviors of LSR Interface (LSR 계면의 접착특성 및 절연파괴거동)

  • Yoon, Seung-Hoon;Nam, Jin-Ho;Lee, Gun-Ju;Choi, Soo-Geol;Shin, Doo-Sung;Ji, Eung-Seo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.232-235
    • /
    • 2002
  • Recently developed liquid silicone rubber (LSR) can be cured by platinum catalyzed additional hydrosilylation mechanism and has the advantage of no byproduct compared to traditional millable peroxide curing silicone rubber. We investigated the characteristics of dielectric breakdown of silicone rubber and adhesion properties between semi-conductive LSR and insulating LSR for high voltage application of pre-molded joint (PMJ). In order to understand the dielectric breakdown characteristics, we used the sheet samples and the paired type rogowski insert electrode system. The breakdown strength and adhesion strength of LSR (E-3) were superior to those of several silicone rubbers. Adhesion strength could be improved by curing at high temperature without post-curing process or enhanced by post-curing process. When LSR (E-3) was cured at $(150^{\circ}C{\times}10min$ semi-conductive )${\times}$ ($175^{\circ}C{\times}10min$ insulation), it showed the high breakdown strength with low standard deviation, and good adhesion strength. In this results, we could apply this process to the fabrication of PMJ without post-curing.

  • PDF

Properties-of Rice Flours Prepared from Milled and Broken Rice Produced by Pre-washing Process (분무수세 건조한 무세미와 부산물 쇄립의 쌀가루 특성)

  • Choi, So-Yeon;Lee, Sang-Hyo;Lee, Young-Tack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.1098-1102
    • /
    • 2005
  • Properties of rice flours prepared from milled and broken rice produced by pre-washing and subsequent drying process were investigated. Compared to untreated ordinary milled rice, pre-washing process slightly increased lightness of rice flour, while decreased yellowness. Both WAI and WSI were higher in the flour from pre-washed rice, and gel consistency was the highest in the flour from pre-washed broken rice. Pre-washed rice showed increased amylograph peak viscosity and reduced setback values. On the other hand, pre-washed broken rice showed decreased peak viscosity and increased setback values. Differential scanning calorimetry (DSC) results showed that the pre-washing process reduced gelatinization onset- and peak temperatures, with increased gelatinization enthalpy. Total bacteria and yeast count were lower in the pre­washed rice, suggesting the pre-washing process could partially eliminate microbial contamination of ordinary milled rice.