• Title/Summary/Keyword: Powerline

Search Result 94, Processing Time 0.042 seconds

A Study on the Drive Circuit Improvement In the Low Impedance Communication (저임피던스 통신 환경에서의 구동회로 개선에 관한 연구)

  • Choi, Tae-Seop;Lim, Seung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.1001-1002
    • /
    • 2006
  • As most of the powerline modems use spread spectrum modulation method which has strong immunity against the narrowband fading, or psk modulation method, the amplitude of the signal contains no useful informations. In this paper, we used class D amplifier to implement the drive circuit of the analog front end, and showed that it has great superiority over other existing drive circuits in rapidly impedance changing power line channel.

  • PDF

Application of High-Current PLC of Soft Magnetic Core Type Coupler (연자성체 코어형 결합기의 대전류 전력선통신 적용)

  • Jeong, Jae-Hwan;Yang, Seung-Ho;Soh, Kyung-Rak
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.155-155
    • /
    • 2018
  • In this study, we measured the communication performance of inductive coupler under high current condition. Ferrite and nanocrystalline cores were used to compare the available PLC communication range and bandwidth for current fluctuations.

  • PDF

Implementation of a dynamic high-performance Notch Filter for Power-Line Communications (전력선통신을 위한 동적 고성능 Notch Filter 구현)

  • Shin, Seong-Kyun;Lee, Byung-Jin;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.221-227
    • /
    • 2013
  • Recent studies have been conducted on powerline communications as a viable alternative to the spread of the spread of the Internet and the Internet as the chief source of information act in the information age, the internet does not reach local Last Mile Solution. Powerline communication, but because it has been designed to transfer power to the high frequency signal to be sent when the close of wireless communications services impacted. The notch filters of a common way to eliminate the interference are used. In this paper, a dynamic high-performance notch filter applying WDF performance was verified through MATLAB and was implemented using a TI's TMS320C6416T DSP board.

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Performance Comparison over Gaussian Channel of Binary Chirp DS-CDMA System for Powerline Communication (전력선 통신을 위한 Binary Chirp DS-CDMA System의 가우시안 채널 하에서 성능 비교)

  • Park, Sung-Wook;Park, Jong-Wook
    • 전자공학회논문지 IE
    • /
    • v.43 no.2
    • /
    • pp.70-74
    • /
    • 2006
  • The performance of conventional direct sequence code division multiple access (DS-CDMA) systems is decreased under environments such as additive white Gaussian noise (AWGN), channel distortion and interference noise due to multiple access user. By means of this parameter, auto correlation value of pseudo noise spreading sequence is decreased at receiver. This techniques which are based on correlation of between signature waveform signal. In this paper, to improve correlation property, we proposed the binary chirp DS-CDMA techniques which combine the DS-CDMA and chirp modulation. The proposed system which is based on binary chirp symbol has a good correlation value. Thus, we called BC DS-CDMA. To evaluate the system's performance, we compare the performance of the proposed systems with DS-CDMA systems under AWGN channel and halogen noise which exists on the powerline. The simulation results show that the proposed method has better performance than conventional technique.

Implementation of PLC-Based Multi-modem for Process Automation of Non-destructive Inspection (비파괴검사 공정자동화를 위한 전력선통신 기반 복합통신장치의 구현)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.822-828
    • /
    • 2013
  • In this paper, a multi-modem for process automation of non-destructive inspection (NDI) which possibly generates various kinds of data is implemented and verified. Here, a variety of data such as control signals, text data, image data generated by inspection devices, sensors, computers are transmitted to the multi-modem via serial, Ethernet, and coaxial cable. We exploit a communication network in which powerlines are used as backbone transmission media. Thus, the implemented multi-modem has various ports and corresponding interfaces for data transmission. As a result of practical experiments, the multi-modem maintains almost constant data rate with little waveform distortion. In addition, the experiments confirm that the modem operates normally under extreme variation of temperature. It is, therefore, considered that the multi-modem can contribute significantly to implement powerline communication (PLC)-based process automation for NDI in which various kinds of data are practically generated.

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

A Study on Broadband Inductive Coupler using Impregnated Nanocrystalline Ribbon (함침된 나노결정립 리본을 이용한 광대역 유도형 결합기 연구)

  • Kim, Hyun-Sik;Ju, Woo-Jin;Sohn, Kyung-Rak
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.599-605
    • /
    • 2019
  • Ferrite cores are used as a soft magnetic material in the fabrication of couplers for inductive powerline communication (PLC). However, it is difficult to adjust the size freely according to the power-line and power-grid environment. In this paper, we report that a nano-crystalline alloy with higher permeability than ferrite can be used as an inductive coupler for non-contact PLC. Since nano-crystalline are produced in the form of a thin ribbon, the size of the coupler can be freely controlled by the number of ribbons wound on the toroidal core. It was fabricated with induction type coupler and showed to be suitable for non-contact power line communication. Experimental results show that the communication bandwidth is 45 Mbps for 100 m and 8 Mbps for 200 m under the current fluctuation of less than 100 A, and the reception ratio is 100%.

Implementation of a Sensor Network in a Welding Workplace Based on IoT for Smart Shipyards (스마트 조선소를 위한 사물인터넷 기반 용접 작업장 센서네트워크 구축)

  • Kim, Hyun Sik;Lee, Gi Seung;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.3
    • /
    • pp.433-439
    • /
    • 2021
  • In this paper, we propose a method to implement an IoT-based sensor network for each workplace of a shipyard. Here, at the most common welding workplace in shipyards, the shipbuilding blocks are used as a communication medium to transmit information such as the worker's location, welding progress, and working hour to a server using LoRa and powerline communication. To achieve the data communication, inductive couplers and hybrid modems have been manufactured and installed on wire feeders and pin jigs to establish a sensor network. As a result of field test, the proposed system shows a success rate of data transmission and a rate of successful recognition of worker's location of about 98% or more. In addition, the process management system platform can record and display the work process data generated at the field in real time. The proposed system can be a starting point for enhancing the competitiveness of Korean shipbuilding industry through the establishment of a smart shipyard.