• 제목/요약/키워드: Powerline

검색결과 94건 처리시간 0.028초

전력선 통신을 위한 채널 특성 분석 (Characteristics Analysis of Powerline Channel for Powerline Communication)

  • 이정훈;서종완;이종주;신명철;성낙환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.558-560
    • /
    • 2000
  • The role of power line is not limited to providing electrical power. Power line fumed out to be an candidate to cope with the existing communication channels. It is need to be measured the properties of power line as communication channels, before successful communication system is possible. This paper presents the characteristics of power line noise and attenuation measurements in the frequency range of $0{\sim}10$ MHz, and then suggests applicable communication techniques in brief. Power line channel is configured in our laboratory and the length of it is 250 meters.

  • PDF

저 비트율 전력선 모뎀에 대한 저압 댁내망의 채널 특성 시뮬레이션 기법에 관한 연구 (A Simulation Technique for the Characterization of the Low-bit-rate Household AC Power Line Communication Channel)

  • 안남호;정태규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, the characteristics of the household AC power line network is analyzed for the low bit rate powerline communication (PLC) in the frequency range from 10㎑ to 450㎑ The PLC channel transfer characteristics including its characteristic impedance are derived based on the network topology which is constructed with the household power lines loaded with the various types of electric apparatus. Both the distributed circuit analysis and the lumped circuit model based analysis are applied for the characterization of the PLC channel and the results are compared by the computer simulations. The analysis illustrates very well the adverse effects caused by the loading of electric apparatus and as well those casued by the reflection of wavers in the household AC Power line communication network.

전력IT를 위한 전력제어용 전력선통신 SoC 개발 (Design of a SoC Architecture based on PLC for Power-IT System)

  • 김영현;명노길;박병석;정강식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.449-450
    • /
    • 2008
  • In this paper, we present the design of a system on a chip(SoC) based on Powerline Communication for Power-IT. The SoC deals with power information obtained from analog to digital converter and transmits this data via powerline. We integrate main processor, ADC and PLC function into a chip. Also a FPGA-based emulation system is introduced to evaluate a proposed SoC architecture.

  • PDF

저임피던스 전력선 채널 환경에 적합한 통신을 위한 구동 회로 설계 (Drive Circuit Design for Smooth Communication in Low Impedance Power Line Channel Environment)

  • 최태섭;최은범;사공석진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 통신소사이어티 추계학술대회논문집
    • /
    • pp.369-373
    • /
    • 2003
  • 홈오토메이션 시스템은 보통 데이터 양이 많지 않아 저속 전력선 통신을 사용하는데, 저속 전력선 통신은 대역 확산 방식과 위상 변조 방식이 사용된다. 이 통신 방식은 신호의 정보가 진폭에 없고, 위상 변화에 있으므로 본 논문에서는 신호가 두 개의 상태로 되는 D급 증폭 회로를 사용하여 저임피던스를 가진 전력선 채널에서 적합한 통신이 되도록 하였다. 현재 전력선 모뎀에 사용되는 전압 구동 회로와 전류 구동 회로를 제작하고, 본 논문에서 설계한 D급 증폭 회로를 이용한 구동 회로와 비교 실험을 하였다. 실험 결과 본 논문에서 설계한 구동 회로가 다른 구동 회로보다 낮은 전력선 채널 임피던스에 대하여 전달 특성이 우수함을 보였다.

  • PDF

유도형 전력선 통신의 전기충전시스템 적용 연구 (A Study on Application of Inductive PLC to Electric Charging System)

  • 손경락;정재환;양승호
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2018년도 춘계학술대회
    • /
    • pp.153-153
    • /
    • 2018
  • In this paper, we have represented basic experiment results for the application of electric vehicle powerline communication using an induction type coupler. The coupler was fabricated using nano-crystalline alloy and it was applied to the charging system of electric vehicles to measure the communication performance. Experimental results showed a channel bandwidth over 48 Mbps.

  • PDF

전력선 통신을 이용한 디멘드 콘트롤러의 개발 (Development of Demand Controller Using Power Line communication)

  • 김호;박해원;이정복;석원엽;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.619-622
    • /
    • 2001
  • In this paper, an intelligent demand control system was introduced. This system is composed of demand controller, RTU, Power Line Modem and HMI program. The developed demand controller was capable of synchronizing with watthour meter recommended by KEPCO. To control distant loads, network function using powerline communication is implemented in RTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved In a several experiments.

  • PDF

전력선 통신 채널의 잡음 특성에 관한 연구 (A Study on Noise Characteristics of Powerline Communication Channel)

  • 최승지;유정훈;오휘명;이재조;이원태;김관호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2696-2698
    • /
    • 2003
  • 전력선 통신 채널(powerline communication channel)은 원래 전력을 전송하기 위한 선로로서 무선 채널 및 그 밖의 다른 통신 채널들과 같이 부가적 가우시안 잡음 환경 등의 표준 모델로 잘 표현되지 않는 특성이 있다. 그리고 1MHz-30MHz 대역에서의 전력선 채널의 잡음은 배경잡음, 연속 신호(continuous wave) 협대역 및 광대역 잡음, 그리고 임펄스 잡음으로 분류될 수 있으며, 특히 고속 데이터 전송 시스템에서는 임펄스 잡음에 의한 영향이 큰 것으로 알려져 있다. 본 논문에서는 아파트형 주거지에서 실측한 주파수 영역 및 시간영역의 잡음 데이터를 제시하고, 이러한 데이터를 바탕으로 연속 신호 잡음을 포함한 배경잡음과 임펄스 잡음의 모델 및 통계적 특성을 제시한다.

  • PDF

고속 전력선 통신용 옥내 저압 전력선 임피던스 측정 (Measurement of Low Voltage Powerline Impedance for High Data Rate Powerline Communications (PLC))

  • 박영진;유정훈;김관호;이재조;박해수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1952-1954
    • /
    • 2003
  • 0.5MHz-40MHz 대역 옥내 저압전력선 (220V) 임피던스를 측정하였다. 측정을 위해 벡터 회로망 분석기와 저압 전력선 결합 장치(coupling unit)를 이용하였다. 결합 장치를 T형 등가회로로 바꾸어, 전체 회로에서 얻은 산란계수를 이용하여 저압 전력선 임피던스를 구했다. 제안된 방법으로 실제 한국형 저층 연립 아파트에 대한 평균 임피던스를 측정하였고, 그 결과 평균 임피던스 약 $100{\Omega}$이었다.

  • PDF

전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발 (Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power)

  • 윤재식;위정철;박중하;송용재;김재헌
    • 전기학회논문지
    • /
    • 제58권11호
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

전력선 접지와 매설배관의 이격거리 실증실험 사례 조사 (Investigation of the Experiment for Separation Distance between Powerline Earth and Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.87-88
    • /
    • 2006
  • There are a number of reported instances of actual pipeline rupture during power line faults caused by melting of the pipe wall. This type of hazard was considered to be among the most serious of AC effects on pipelines in an international survey, comparable to the personnel safety hazard. Moreover, resistance coupling is not only a risk when the pipeline parallels a power line but also when they cross. One method of minimizing the effects of resistive coupling is by maintaining an appropriate separation distance between the pipeline and tower. This paper investigate the experiment for separation distance between the powerline earth and pipelines.

  • PDF