• Title/Summary/Keyword: Powerline

Search Result 94, Processing Time 0.026 seconds

Portable ECG Sensor Module and Monitoring System Implementation Considering Reduction of Powerline Noise and Baseline Wander (전원잡음과 기저선변동을 고려한 이동형 ECG 센서모듈 및 모니터링 시스템 구현)

  • Oh Do-Chang;Choi Dong-Hyuk;Lee Hong-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.1022-1028
    • /
    • 2006
  • A portable ECG sensor module and monitoring system which has the powerline noise reduction and the baseline wander removal is proposed. A small-szie ECG sensor H/W module with the 8-bits microprocessor is implemented. The ECG waveform can be inspected anytime with PDA in real time, and transmitted to the PC through wireless LAN. Portable ECG system can offer the environment that give the lasting medical service to the elderly and the long-time hospitalized patients at the wanted place, and the system can be attached to the chair, wheel chair, treadmill, elderly walker and used to monitor the health condition of man

A Study on the Elimination of 60Hz Powerline Inteirference for the Automated Diagnosis of Electrocsrdiogram (심전도 자동진단을 위한 60Hz 전원잡음 제거 필터에 관한 연구)

  • Kweon, Hyukje;Jeong, Keesam;Lee, Myoungho
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.99-108
    • /
    • 1996
  • Diverse digital filters have been designed previously to eliminate powerline(AC) interference in the electrocardiouam. This paper describes filtering methods which have been developed recursive notch, adaptive, IEF(Incremental Estimation Filter) and proposes a new AIEF(Advanced Incremental Estimation Filter) method. The performances of these filters are compared on artificial signals as well as actual ECG signals with the aid of validated CSE(Common Standards for Quantitative Electrocardiowaphy). AC interference in this database is shown to exhibit two qualities especially relevant to filter design : considerable deviations from a nominal 60Hz frequency and substantial noise at higher harmonics.

  • PDF

Communication Performance of Inductive Coupler Using Nanocrystalline Alloy (나노결정립 합금을 이용한 유도형 결합기의 통신 성능)

  • Yang, Seung-Ho;Jeong, Jae-Hwan;Sohn, Kyung-Rak
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.154-154
    • /
    • 2018
  • Conventional inductive powerline communications typically use ferrite cores. However, since the recent nanocrystalline cores are expected to perform better, this paper aims to measure the performance of inductive couplers using nanocrystalline cores. To do this, we used inductive powerline communications to observe the communication range when increasing the number of cores from one to five. This experiment shows that we have the best communication performance when we connect 5 cores.

  • PDF

Development of Remote Load Management System Using PowerLine Communication (전력선 통신을 이용한 원격부하관리시스템 개발)

  • Na, Chae-Dong;Lee, Sung-Bum;Jeong, Eull-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an simple load management system was introduced. This system is composed of Main Controller, DTU(Dispersion Terminal Unit), Power Line Modem and HMI (Human Machine Interface) program. To control distant loads, network function using powerline communication is implemented in DTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved in a several experiments.

  • PDF

Measurement of Channel Impedance Characteristics for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 특성 측정)

  • Heo Yoon-Seok;Kim Chul;Hong Bong-Hwa;Lee Dae-Young;Jun Kye-Suk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.11
    • /
    • pp.79-86
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency $30khz\~1Mhz$ band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

A Powerline-based Legacy-line Communication System for Implementation of a Communication Network in Ship (선박 내 통신네트워크 구축을 위한 전력선 기반 무배선통신시스템)

  • Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1831-1838
    • /
    • 2015
  • In this paper, a method of implementing a communication network in ship, which exploits a powerline-based legacy-line communication system (LLC), is presented. We develop an inductive coupling unit and a multi-interface device to connect a data communication terminal to the powerline. As a result of operation tests for the ship under working, the implemented LLC shows a transmission rate of at least 25.8 Mbps in the distance of 200 m away with 100% success rate. Thus, the system can be a useful alternative to implement a communication network in ship without additional channels. Being easy to be implemented and supporting various interfaces for data communication, the presented system will be very effective when a real-time monitoring system is launched in future digital ship.

A Medium Access Control Protocol for Sensor Data in Powerline Communications (전력선통신방식에서 센서데이터 전달을 위한 MAC 프로토콜 설계)

  • Jin, Kyo-Hong;Choi, Pyung-Suk;Park, Mu-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.257-263
    • /
    • 2006
  • With the ever increasing demand for data communication methods, powerline communication has become in interesting alternative method for data communication in home networking. For the purpose of home safety, several sensors will be installed at door, windows, gas alarm, etc. When considering home networking, the sensor data as well as other types of data should be supported in powerline communication. Usually the sensor data do not have priority over isochronous traffics (voice, video traffic), but in the case of urgent situation at home, the data of sensor being aware of the situation should be transmitted earlier than others. The objective in this paper is to develop a method for supporting an urgent data in home networking using powerline communication. We propose a modified algorithm of HomePlug 1.0 and show the results of computer simulation.

Implement of a Watt-Hour Meter Monitoring System using Powerline Communication (전력선 통신을 이용한 전력량계 모니터링 시스템 구현)

  • Park, Keun-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1143-1148
    • /
    • 2013
  • This paper deals a watt-hour meter monitor system with applying a Power Line Communication (PLC) modem and a Data Concentrator Unit (DCU). PLC modem uses the power line, so there is no need to install dedicated wiring. This system makes it possible to monitor the amount of electricity of previous current month metering data, so it can easily apply a PC-management for the electric charges and maintenance with gathering the metering data.